107 research outputs found

    Microbubble potentiated transcranial duplex ultrasound enhances IV thrombolysis in acute stroke

    Get PDF
    Background: We studied whether 2MHz transcranial color-coded duplex ultrasound (TCCD), combined with a second generation ECA, accelerate IV rtPA-thrombolysis in the acute phase of MCA stroke more than TCCD monitoring alone. Methods: Non-randomized acute MCA stroke patients undergoing IV rtPA-thrombolysis and 2MHZ-TCCD monitoring over 60min, with (N=11) or without (N=15) additional continuous ECA (5ml, SonoVue®) perfusion, were compared. Recanalization of the MCA was measured pre- and post-thrombolysis with the thrombolysis in brain ischemia (TIBI) grading system, clinical outcome was assessed at admission and 24h after treatment using the NIH stroke scale (NIHSS). Results: Patients who received ECA improved their NIHSS significantly more than those who were only TCCD monitored (Mann-Whitney U=48.0; P=0.050), and their flow signal improved more (Mann-Whitney U=40.0; P<0.03). Conclusions: The results of this pilot study show that in IV-thrombolysis the use of ECA in addition to TCCD monitoring lead to a greater immediate clinical improvement and to a better flow signa

    Use of the Enterprise™ Intracranial Stent for Revascularization of Large Vessel Occlusions in Acute Stroke

    Get PDF
    Background and Purpose:: Major cerebral thromboembolism often resists recanalization with currently available techniques. The authors present their initial experience with a self-expanding stent for use in intracranial vascular reconstruction, permitting immediate recanalization of acute thromboembolic occlusions of the anterior circulation. Patients and Methods:: Patients treated with the Cordis Enterprise™ self-expanding intracranial stent system for acute thromboembolic occlusion of the major anterior cerebral arteries were included. Treatment comprised systemic and intraarterial thrombolysis, mechanical thrombectomy, and stent placement. Stent deployment, recanalization rate by means of Thrombolysis In Cerebral Infarction (TICI) scores and the clinical outcome were all assessed. Results:: Six patients presenting with acute carotid T (n = 2) or proximal middle cerebral artery occlusion (n = 4) were treated. The mean National Institutes of Health Stroke Scale (NIHSS) score at presentation was 14; the mean age was 57 years. Successful stent deployment and immediate recanalization were achieved in all six with a TICI score of ≥ 2. Neither distal emboli nor any procedure-related complications were encountered. One patient developed symptomatic intracerebral hemorrhage and two patients needed decompressive craniectomy after treatment. The mean NIHSS score at 10 days was 10, but only one patient showed a complete recovery at 3 months. Conclusion:: Intracranial placement of the Enterprise™ self-expanding stent has proven to be feasible and efficient in achieving immediate recanalization of occluded main cerebral arteries. The use of antiplatelet therapy after treatment may, however, increase the risk of reperfusion intracerebral hemorrhag

    3D fat-saturated T1 SPACE sequence for the diagnosis of cervical artery dissection

    Get PDF
    Introduction: This study aims to demonstrate the added value of a 3D fat-saturated (FS) T1 sampling perfection with application-optimised contrast using different flip angle evolutions (SPACE) sequence compared to 2D FS T1 spin echo (SE) for the diagnosis of cervical artery dissection. Methods: Thirty-one patients were prospectively evaluated on a 1.5-T MR system for a clinical suspicion of acute or subacute cervical artery dissection with 3D T1 SPACE sequence. In 23 cases, the axial 2D FS T1 SE sequence was also used; only these cases were subsequently analysed. Two neuroradiologists independently and blindly assessed the 2D and 3D T1 sequences. The presence of recent dissection (defined as a T1 hyperintensity in the vessel wall) and the quality of fat suppression were assessed. The final diagnosis was established in consensus, after reviewing all the imaging and clinical data. Results: Overall sensitivity and specificity were 0.929 and 1 for axial T1 SE, and 0.965 and 0.945 for T1 SPACE (P > 0.05), respectively. The two readers had excellent agreement for both sequences (k = 1 and 0.8175 for T1 SE and T1 SPACE, respectively; P > 0.05). The quality of the fat saturation was similar. Very good fat saturation was obtained in the upper neck. Multiplanar reconstructions were very useful in tortuous regions, such as the atlas loop of the vertebral artery or the carotid petrous entry. 3D T1 SPACE sequence has a shorter acquisition time (3min 25s versus 5min 32s for one T1 SE sequence) and a larger coverage area. Conclusion: 3D T1 SPACE sequence offers similar information with its 2D counterpart, in a shorter acquisition time and larger coverage are

    An exploratory cohort study of sensory extinction in acute stroke: prevalence, risk factors, and time course

    Get PDF
    Most studies on sensory extinction have focused on selected patients with subacute and chronic right hemisphere lesions. In studies conducted on acute stroke patients, risk factors and time course were not evaluated. Our aim was to determine the prevalence, risk factors, and time course of sensory extinction in the acute stroke setting. Consecutive patients with acute stroke were tested for tactile, visual, auditory, and auditory-tactile cross-modal extinction, as well as for peripersonal visuospatial neglect (PVN). Tests were repeated at 2, 7, 15, 30, and 90 days after initial examination. A multivariable logistic regression analysis was performed to test the association between sensory extinction and demographic and clinical risk factors. Seventy-three patients (38.4% women) were recruited: 64 with ischemic stroke and nine with haemorrhagic stroke. Mean age was 62.3 years (95% CI 58.8-65.7), mean NIHSS score was 1.6 (95% CI 1.2-2.1), and mean time to first examination was 4.1 days (95% CI 3.5-4.8). The overall prevalence of all subtypes of sensory extinction was 13.7% (95% CI 6.8-23.8). Tactile extinction was the most frequent subtype with a prevalence of 8.2% (95% CI 3.1-17.0). No extinction was found beyond 15 days after the first examination. After adjustment for age, sex, lesion side, type of stroke, time to first examination and stroke severity, a lesion volume ≥2 mL (adjusted OR = 38.88, p = 0.04), and presence of PVN (adjusted OR = 24.27, p = 0.04) were independent predictors of sensory extinction. The insula, the putamen, and the pallidum were the brain regions most frequently involved in patients with sensory extinction. Extinction is a rare and transient phenomenon in patients with minor stroke. The presence of PVN and lesion volume ≥2 mL are independent predictors of sensory extinction in acute stroke

    Preclinical testing of a new clot-retrieving wire device using polyvinyl alcohol hydrogel vascular models

    Get PDF
    Introduction: Cerebral embolism is the principal cause of cerebral infarction. Recently, mechanical embolectomy has been proposed as an effective method. We performed a preclinical evaluation of a new mechanical clot-retrieving wire. Methods: This clot-retrieving wire consisted of three nitinol loops at the tip of a microguidewire. These three loops could be collapsed into a 0.018-inch wire compatible microcatheter. Each loop was 8mm long and 3.5mm wide. For simulation, polyvinyl alcohol (PVA) vascular anatomical models of the human carotid (eight models) and vertebrobasilar (three models) circulation were constructed. A pulsatile flow circulation system was used. Embolic clots were produced using pig blood plasma. The microcatheter and the microguidewire were advanced beyond the clot. The wire was then exchanged for the retrieving wire. The microcatheter was then pulled slightly back to open the loops. The clot was then caught by withdrawal of the system. Once caught, the clot was retrieved to the guiding catheter tip. We investigated the following points: ease of device deployment, clot capture ability, clot removal against blood flow and removal of the clot out of the introducer system. Results: A total of 104 procedures were performed in 11 PVA models and evaluated. The drop rate was 19%. We succeeded in partial and total recanalization in 51.0% of the procedures (53/104) within 30minutes. Conclusion: This new clot-retrieving wire could be useful for mechanical clot extraction in strok

    Carotid plaque surface echogenicity predicts cerebrovascular events: An Echographic Multicentric Swiss Study.

    Get PDF
    BACKGROUND AND PURPOSE To determine the prognostic value for ischemic stroke or transitory ischemic attack (TIA) of plaque surface echogenicity alone or combined to degree of stenosis in a Swiss multicenter cohort METHODS: Patients with ≥60% asymptomatic or ≥50% symptomatic carotid stenosis were included. Grey-scale based colour mapping was obtained of the whole plaque and of its surface defined as the regions between the lumen and respectively 0-0.5, 0-1, 0-1.5, and 0-2 mm of the outer border of the plaque. Red, yellow and green colour represented low, intermediate or high echogenicity. Proportion of red color on surface (PRCS) reflecting low echogenictiy was considered alone or combined to degree of stenosis (Risk index, RI). RESULTS We included 205 asymptomatic and 54 symptomatic patients. During follow-up (median/mean 24/27.7 months) 27 patients experienced stroke or TIA. In the asymptomatic group, RI ≥0.25 and PRCS ≥79% predicted stroke or TIA with a hazard ratio (HR) of respectively 8.7 p = 0.0001 and 10.2 p < 0.0001. In the symptomatic group RI ≥0.25 and PRCS ≥81% predicted stroke or TIA occurrence with a HR of respectively 6.1 p = 0.006 and 8.9 p = 0.001. The best surface parameter was located at 0-0.5mm. Among variables including age, sex, degree of stenosis, stenosis progression, RI, PRCS, grey median scale values and clinical baseline status, only PRCS independently prognosticated stroke (p = 0.005). CONCLUSION In this pilot study including patients with at least moderate degree of carotid stenosis, PRCS (0-0.5mm) alone or combined to degree of stenosis strongly predicted occurrence of subsequent cerebrovascular events

    Risk factors, aetiology and outcome of ischaemic stroke in young adults: the Swiss Young Stroke Study (SYSS).

    Get PDF
    Ischaemic stroke (IS) in young adults has been increasingly recognized as a serious health condition. Stroke aetiology is different in young adults than in the older population. This study aimed to investigate aetiology and risk factors, and to search for predictors of outcome and recurrence in young IS patients. We conducted a prospective multicentre study of consecutive IS patients aged 16-55 years. Baseline demographic data, risk factors, stroke aetiology including systematic genetic screening for Fabry disease and severity were assessed and related to functional neurological outcome (modified Rankin Scale, mRS), case fatality, employment status, place of residence, and recurrent cerebrovascular events at 3 months. In 624 IS patients (60 % men), median age was 46 (IQR 39-51) years and median NIHSS on admission 3 (IQR 1-8). Modifiable vascular risk factors were found in 73 %. Stroke aetiology was mostly cardioembolism (32 %) and of other defined origin (24 %), including cervicocerebral artery dissection (17 %). Fabry disease was diagnosed in 2 patients (0.3 %). Aetiology remained unknown in 20 %. Outcome at 3 months was favourable (mRS 0-1) in 61 % and fatal in 2.9 %. Stroke severity (p < 0.001) and diabetes mellitus (p = 0.023) predicted unfavourable outcome. Stroke recurrence rate at 3 months was 2.7 %. Previous stroke or TIA predicted recurrent cerebrovascular events (p = 0.012). In conclusion, most young adults with IS had modifiable vascular risk factors, emphasizing the importance of prevention strategies. Outcome was unfavourable in more than a third of patients and was associated with initial stroke severity and diabetes mellitus. Previous cerebrovascular events predicted recurrent ones

    Prior Stroke in PFO Patients Is Associated With Both PFO-Related and -Unrelated Factors.

    Get PDF
    Background and Purpose: To identify factors associated with prior stroke at presentation in patients with cryptogenic stroke (CS) and patent foramen ovale (PFO). Methods: We studied cross-sectional data from the International PFO Consortium Study (NCT00859885). Patients with first-ever stroke and those with prior stroke at baseline were analyzed for an association with PFO-related (right-to-left shunt at rest, atrial septal aneurysm, deep venous thrombosis, pulmonary embolism, and Valsalva maneuver) and PFO-unrelated factors (age, gender, BMI, hypertension, diabetes mellitus, hypercholesterolemia, smoking, migraine, coronary artery disease, aortic plaque). A multivariable analysis was used to adjust effect estimation for confounding, e.g., owing to the age-dependent definition of study groups in this cross-sectional study design. Results: We identified 635 patients with first-ever and 53 patients with prior stroke. Age, BMI, hypertension, diabetes mellitus, hypercholesterolemia, coronary artery disease, and right-to-left shunt (RLS) at rest were significantly associated with prior stroke. Using a pre-specified multivariable logistic regression model, age (Odds Ratio 1.06), BMI (OR 1.06), hypercholesterolemia (OR 1.90) and RLS at rest (OR 1.88) were strongly associated with prior stroke.Based on these factors, we developed a nomogram to illustrate the strength of the relation of individual factors to prior stroke. Conclusion: In patients with CS and PFO, the likelihood of prior stroke is associated with both, PFO-related and PFO-unrelated factors

    Recanalization therapies in acute ischemic stroke patients: impact of prior treatment with novel oral anticoagulants on bleeding complications and outcome

    No full text
    We explored the safety of intravenous thrombolysis (IVT) or intra-arterial treatment (IAT) in patients with ischemic stroke on non-vitamin K antagonist oral anticoagulants (NOACs, last intake <48 hours) in comparison with patients (1) taking vitamin K antagonists (VKAs) or (2) without previous anticoagulation (no-OAC)
    corecore