22 research outputs found

    Comparison of Stress-Rest and Stress-LGE Analysis Strategy in Patients Undergoing Stress Perfusion Cardiovascular Magnetic Resonance

    Get PDF
    BACKGROUND: Stress perfusion cardiovascular magnetic resonance can be performed without rest perfusion for the quantification of ischemia burden. However, the optimal method of analysis is uncertain. METHODS: We identified 666 patients from CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) with complete stress perfusion, rest perfusion, late gadolinium enhancement (LGE), and quantitative coronary angiography data. For each segment of the 16-segment model, perfusion was visually graded during stress and rest imaging, with infarct transmurality assessed from LGE imaging. In the stress-LGE analysis, a segment was defined as ischemic if it had a subendocardial perfusion defect with no infarction. Rest perfusion was not used in this analysis. We compared the diagnostic accuracy of stress-LGE analysis against quantitative coronary angiography and the stress-rest method validated in the original CE-MARC analysis. The diagnostic accuracy of the stress-LGE method was evaluated with different thresholds of infarct transmurality used to define whether an infarcted segment had peri-infarct ischemia. RESULTS: The optimal stress-LGE analysis classified all segments with a stress perfusion defect as ischemic unless they had >75% infarct transmurality (area under the curve, 0.843; sensitivity, 75.6%; specificity, 93.1%; P<0.001). This analysis method has superior diagnostic accuracy to the stress-rest method (area under the curve, 0.834; sensitivity, 73.6%; specificity, 93.1%; P<0.001, P value for difference=0.02). Patients were followed-up for median 6.5 years for major adverse cardiovascular events, with the presence of inducible ischemia by either the stress-LGE or stress-rest analysis being similar and strongly predictive (hazard ratio, 2.65; P<0.001, for both). CONCLUSIONS: In this analysis of CE-MARC, the optimum definition of inducible ischemia was the presence of a stress-induced perfusion defect without transmural infarction. This definition improved the diagnostic accuracy compared with the stress-rest analysis validated in the original study. The absence of ischemia by either analysis strategy conferred a favorable long-term prognosis

    Clinical evaluation of two dark blood methods of late gadolinium quantification of ischemic scar

    Get PDF
    BACKGROUND: Late gadolinium enhancement (LGE) imaging was validated for diagnosis and quantification of myocardial infarction (MI). Despite good contrast between scar and normal myocardium, contrast between blood pool and myocardial scar can be limited. Dark blood LGE sequences attempt to overcome this issue. PURPOSE: To evaluate T1 rho (T1 ρ)-prepared dark blood sequence and compare to blood nulled (BN) phase sensitive inversion recovery (PSIR) and standard myocardium nulled (MN) PSIR for detection and quantification of scar. STUDY TYPE: Prospective. POPULATION: Thirty patients with prior MI. FIELD STRENGTH/SEQUENCE: Patients underwent identical 1.5 T MRI protocols. Following routine LGE imaging, a slice with scar, remote myocardium, and blood pool was selected. PSIR LGE was repeated with inversion time set to MN, to BN, and T1 ρ FIDDLE (flow-independent dark-blood delayed enhancement) in random order. ASSESSMENT: Three observers. Qualitative assessment of confidence scores in scar detection and degree of transmurality. Quantitative assessment of myocardial scar mass (grams), and contrast-to-noise ratio (CNR) measurements between scar, blood pool, and myocardium. STATISTICAL TESTS: Repeated-measures analysis of variance (ANOVA) with Bonferroni correction, coefficient of variation, and the Cohen κ statistic. RESULTS: CNRscar-blood was significantly increased for both BN (27.1 ± 10.4) and T1 ρ (30.2 ± 15.1) compared with MN (15.3 ± 8.4 P < 0.001 for both sequences). There was no significant difference in CNRscar-myo between BN (55.9 ± 17.3) and MN (51.1 ± 17.8 P = 0.512); both had significantly higher CNRscar-myo compared with the T1 ρ (42.6 ± 16.9 P = 0.007 and P = 0.014, respectively). No significant difference in scar size between LGE methods: MN (2.28 ± 1.58 g) BN (2.16 ± 1.57 g) and T1 ρ (2.29 ± 2.5 g). Confidence scores were significantly higher for BN (3.87 ± 0.346) compared with MN (3.1 ± 0.76 P < 0.001) and T1 ρ (3.20 ± 0.71 P < 0.001). DATA CONCLUSION: PSIR with inversion time (TI) set for blood nulling and the T1 ρ LGE sequence demonstrated significantly higher scar to blood CNR compared with routine MN. PSIR with TI set for blood nulling demonstrated significantly higher reader confidence scores compared with routine MN and T1 ρ LGE, suggesting routine adoption of a BN PSIR approach might be appropriate for LGE imaging. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018

    CMR quantitation of change in mitral regurgitation following transcatheter aortic valve replacement (TAVR): impact on left ventricular reverse remodeling and outcome.

    Get PDF
    Current echocardiographic data reporting the impact of concomitant mitral regurgitation (MR) on outcome in patients who undergo transcatheter aortic valve replacement (TAVR) are conflicting. Using cardiovascular magnetic resonance (CMR) imaging, this study aimed to assess the impact of MR severity on cardiac reverse remodeling and patient outcome. 85 patients undergoing TAVR with CMR pre- and 6 m post-TAVR were evaluated. The CMR protocol included cines for left (LV) and right ventricular (RV) volumes, flow assessment, and myocardial scar assessment by late gadolinium enhancement (LGE). Patients were dichotomised according to CMR severity of MR fraction at baseline ('non-significant' vs 'significant') and followed up for a median duration of 3 years. Forty-two (49%) patients had 'significant MR' at baseline; they had similar LV and RV size and function compared to the 'non-significant MR' group but had greater LV mass at baseline. In those with significant MR at baseline, 77% (n = 32) had a reduction in MR post-TAVR, moving them into the 'non-significant' category at 6-months, with an overall reduction in MR fraction from 34 to 17% (p < 0.001). Improvement in MR was not associated with more favourable cardiac reverse remodeling when compared with the 'non-improvers'. Significant MR at baseline was not associated with increased mortality at follow-up. Significant MR is common in patients undergoing TAVR and improves in the majority post-procedure. Improvement in MR was not associated with more favourable LV reverse remodeling and baseline MR severity was not associated with mortality

    Meta‐analysis of echocardiographic quantification of left ventricular filling pressure

    Get PDF
    Aims The clinical reliability of echocardiographic surrogate markers of left ventricular filling pressures (LVFPs) across different cardiovascular pathologies remains unanswered. The main objective was to evaluate the evidence of how effectively different echocardiographic indices estimate true LVFP. Methods and results Design: this is a systematic review and meta‐analysis. Data source: Scopus, PubMed and Embase. Eligibility criteria for selecting studies were those that used echocardiography to predict or estimate pulmonary capillary wedge pressure or left ventricular end‐diastolic pressures. Twenty‐seven studies met criteria. Only eight studies (30%) reported both correlation coefficient and bias between non‐invasive and invasively measured LVFPs. The majority of studies (74%) recorded invasive pulmonary capillary wedge pressure as a surrogate for left ventricular end‐diastolic pressures. The pooled correlation coefficient overall was r = 0.69 [95% confidence interval (CI) 0.63–0.75, P < 0.01]. Evaluation by cohort demonstrated varying association: heart failure with preserved ejection fraction (11 studies, n = 575, r = 0.59, 95% CI 0.53–0.64) and heart failure with reduced ejection fraction (8 studies, n = 381, r = 0.67, 95% CI 0.61–0.72). Conclusions Echocardiographic indices show moderate pooled association to invasively measured LVFP; however, this varies widely with disease state. In heart failure with preserved ejection fraction, no single echocardiography‐based metric offers a reliable estimate. In heart failure with reduced ejection fraction, mitral inflow‐derived indices (E/e′, E/A, E/Vp, and EDcT) have reasonable clinical applicability. While an integrated approach of several echocardiographic metrics provides the most promise for estimating LVFP reliably, such strategies need further validation in larger, patient‐specific studies

    Detrimental immediate and medium-term clinical effects of right ventricular pacing in patients with myocardial fibrosis.

    Get PDF
    Background: Long-term right ventricular (RV) pacing leads to heart failure or a decline in left ventricular (LV) function in up to a fifth of patients. We aimed to establish whether patients with focal fibrosis detected on late gadolinium enhancement cardiovascular magnetic resonance (CMR) have deterioration in LV function after RV pacing. Methods: We recruited 84 patients with LV ejection fraction ≥40% into 2 observational CMR studies. Patients (n=34) with a dual-chamber device and preserved atrioventricular conduction underwent CMR in 2 asynchronous pacing modes (atrial asynchronous and dual-chamber asynchronous) to compare intrinsic atrioventricular conduction with forced RV pacing. Patients (n=50) with high-grade atrioventricular block underwent CMR before and 6 months after pacemaker implantation to investigate the medium-term effects of RV pacing. Results: The key findings were (1) initiation of RV pacing in patients with fibrosis, compared with those without, was associated with greater immediate changes in both LV end-systolic volume index (5.3±3.5 versus 2.1±2.4 mL/m2; P1.1 g of fibrosis with 90% sensitivity and 70% specificity. Conclusions: Fibrosis detected on CMR is associated with immediate- and medium-term deterioration in LV function following RV pacing and could be used to identify those at risk of heart failure before pacemaker implantation

    Left ventricular thrombus formation in myocardial infarction is associated with altered left ventricular blood flow energetics.

    Get PDF
    Aims: The main aim of this study was to characterize changes in the left ventricular (LV) blood flow kinetic energy (KE) using four-dimensional (4D) flow cardiovascular magnetic resonance imaging (CMR) in patients with myocardial infarction (MI) with/without LV thrombus (LVT). Methods and results: This is a prospective cohort study of 108 subjects [controls = 40, MI patients without LVT (LVT- = 36), and MI patients with LVT (LVT+ = 32)]. All underwent CMR including whole-heart 4D flow. LV blood flow KE wall calculated using the formula: KE=12 ρblood . Vvoxel . v2, where ρ = density, V = volume, v = velocity, and was indexed to LV end-diastolic volume. Patient with MI had significantly lower LV KE components than controls (P  0.05). The relative drop in A-wave KE from mid-ventricle to apex and the proportion of in-plane KE were higher in patients with LVT+ compared with LVT- (87 ± 9% vs. 78 ± 14%, P = 0.02; 40 ± 5% vs. 36 ± 7%, P = 0.04, respectively). The time difference of peak E-wave KE demonstrated a significant rise between the two groups (LVT-: 38 ± 38 ms vs. LVT+: 62 ± 56 ms, P = 0.04). In logistic-regression, the relative drop in A-wave KE (beta = 11.5, P = 0.002) demonstrated the strongest association with LVT. Conclusion: Patients with MI have reduced global LV flow KE. Additionally, MI patients with LVT have significantly reduced and delayed wash-in of the LV. The relative drop of distal intra-ventricular A-wave KE, which represents the distal late-diastolic wash-in of the LV, is most strongly associated with the presence of LVT

    4D Flow Cardiac MR in Primary Mitral Regurgitation

    Get PDF
    Background Four-dimensional-flow cardiac MR (4DF-MR) offers advantages in primary mitral regurgitation. The relationship between 4DF-MR-derived mitral regurgitant volume (MR-Rvol) and the post-operative left ventricular (LV) reverse remodeling has not yet been established. Purpose To ascertain if the 4DF-MR-derived MR-Rvol correlates with the LV reverse remodeling in primary mitral regurgitation. Study Type Prospective, single-center, two arm, interventional vs. nonintervention observational study. Population Forty-four patients (male N = 30; median age 68 [59–75]) with at least moderate primary mitral regurgitation; either awaiting mitral valve surgery (repair [MVr], replacement [MVR]) or undergoing “watchful waiting” (WW). Field Strength/Sequence 5 T/Balanced steady-state free precession (bSSFP) sequence/Phase contrast imaging/Multishot echo-planar imaging pulse sequence (five shots). Assessment Patients underwent transthoracic echocardiography (TTE), phase-contrast MR (PMRI), 4DF-MR and 6-minute walk test (6MWT) at baseline, and a follow-up PMRI and 6MWT at 6 months. MR-Rvol was quantified by PMRI, 4DF-MR, and TTE by one observer. The pre-operative MR-Rvol was correlated with the post-operative decrease in the LV end-diastolic volume index (LVEDVi). Statistical Tests Included Student t-test/Mann–Whitney test/Fisher's exact test, Bland–Altman plots, linear regression analysis and receiver operating characteristic curves. Statistical significance was defined as P < 0.05. Results While Bland–Altman plots demonstrated similar bias between all the modalities, the limits of agreement were narrower between 4DF-MR and PMRI (bias 15; limits of agreement −36 mL to 65 mL), than between 4DF-MR and TTE (bias −8; limits of agreement −106 mL to 90 mL) and PMRI and TTE (bias −23; limits of agreement −105 mL to 59 mL). Linear regression analysis demonstrated a significant association between the MR-Rvol and the post-operative decrease in the LVEDVi, when the MR-Rvol was quantified by PMRI and 4DF-MR, but not by TTE (P = 0.73). 4DF-MR demonstrated the best diagnostic performance for reduction in the post-operative LVEDVi with the largest area under the curve (4DF-MR 0.83; vs. PMRI 0.78; and TTE 0.51; P = 0.89). Data Conclusion This study demonstrates the potential clinical utility of 4DF-MR in the assessment of primary mitral regurgitation
    corecore