54 research outputs found

    Geotechnical Design of an Offshore Gravity Base Structure

    Get PDF
    The paper focuses on the geotechnical design issues facing the design team responsible for the provision of an offshore Gravity Base Structure (GBS) to act as a clump weight for a Power Buoy located in the Lyell field of the northern North Sea, United Kingdom. The structure is to be positioned on the seabed, where ground conditions are considered variable but in general comprise of a surface layer of loose to very dense silty sand, underlain by a thick sequence of firm to very stiff sandy clay. Geotechnical data specific to the location of the GBS is limited; problems encountered during testing allowed only three cone penetration tests to be carried out to maximum depth of 12m and sampling for subsequent laboratory testing was not possible. However, correlation between the results of these tests and CPT results for other areas in the North Sea, allowed geotechnical properties to be inferred and to be used as the basis for the geotechnical design of the foundation. Assessment of the bearing capacity of the structure under hydrodynamic loading, as well as the resistance to sliding indicated that there maybe a risk of instability. As a consequence, a perimeter skirt was specified in order to reduce this risk. A discussion of the geotechnical issues considered during the design process is presented. Other design issues such as cyclic loading and penetration resistance in relation to a perimeter skirt, were considered and are commented on within this paper. The case history highlights some of the design problems faced by geotechnical engineers when designing structures for the offshore environment, and emphasizes the necessity for a comprehensive and, site specific, ground investigation, in order to facilitate the design process

    The Design and Construction of a Reinforced Embankment on Soft Compressible Soil

    Get PDF
    The paper centres on the design and construction of a leachate lagoon at a landfill site located in Essex, United Kingdom (UK). The lagoon is to be used for the storage of between 150,000m3 and 200,000m3 of leachate generated by the adjacent landfill site as part of its treatment process. The location of the lagoon is on the southern boundary of the site, and is bounded to the north by the landfill itself, to the east by an existing leachate treatment lagoon and to the south and west by a flood defence bund for an adjacent creek and the Thames estuary beyond. Due to the proposed capacity and size of the lagoon, it qualifies in the UK as a reservoir under the 1975 Reservoirs Act and the design and construction is therefore constrained by this legislation. The area proposed for the lagoon is generally level, but with groundwater levels close to, or at, the ground surface. Waste dating from the 1950’s underlies the site and this overlies a generally soft stratum of alluvial clays and sands. A similar, but earlier, lagoon encountered significant difficulties during construction associated with the high groundwater levels and the trafficability of the waste and the soft alluvial materials. A discussion of the geotechnical and environmental issues considered during the design process is presented and the need for responsive design during the construction phase of a project is highlighted. The benefits of value engineering in civil engineering are also discussed in the context of design and construction projects. By their very nature, civil engineering projects such as this require imaginative and innovative design solutions, coupled with the use of non-traditional geomaterials. A discussion of the geosynthetics employed at this site is provided, in the context of their primary and secondary applications

    Near infrared spectroscopic measurement of strain in rocks

    Get PDF
    The measurement of strain is a fundamental and widely studied parameter in engineering, rock mechanics, construction and materials testing. Contact sensors often used in these fields require contact with the target surface throughout the duration of a strain event. Non-contact methods typically require that that the measurement surface is prepared and often coated prior to testing. This paper considers the potential application of near infrared spectroscopy as a non-contact technique for the measurement of strain on natural surfaces. Excellent correlation was found between surface measurements of visible-NIR spectra and longitudinal strain taken during indirect Brazilian Disc Test for samples of sandstone, marble and basalt

    Mitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions [version 3; peer review: 1 approved, 1 approved with reservations]

    Get PDF
    BACKGROUND: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). METHODS: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. RESULTS: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. CONCLUSIONS: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions

    Validation of left atrial volume correction for single plane method on four-chamber cine cardiac MRI

    Get PDF
    Background: Left atrial (LA) assessment is an important marker of adverse cardiovascular outcomes. Cardiovascular magnetic resonance (CMR) accurately quantifies LA volume and function based on biplane long-axis imaging. We aimed to validate single-plane-derived LA indices against the biplane method to simplify the post-processing of cine CMR. Methods: In this study, 100 patients from Leeds Teaching Hospitals were used as the derivation cohort. Bias correction for the single plane method was applied and subsequently validated in 79 subjects. Results: There were significant differences between the biplane and single plane mean LA maximum and minimum volumes and LA ejection fraction (EF) (all p < 0.01). After correcting for biases in the validation cohort, significant correlations in all LA indices were observed (0.89 to 0.98). The area under the curve (AUC) for the single plane to predict biplane cutoffs of LA maximum volume ≥ 112 mL was 0.97, LA minimum volume ≥ 44 mL was 0.99, LA stroke volume (SV) ≤ 21 mL was 1, and LA EF ≤ 46% was 1, (all p < 0.001). Conclusions: LA volumetric and functional assessment by the single plane method has a systematic bias compared to the biplane method. After bias correction, single plane LA volume and function are comparable to the biplane method

    A comparison of PM2.5-bound polycyclic aromatic hydrocarbons in summer Beijing (China) and Delhi (India)

    Get PDF
    Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous pollutants in air, soil, and water and are known to have harmful effects on human health and the environment. The diurnal and nocturnal variations of 17 PAHs in ambient particle-bound PAHs were measured in urban Beijing (China) and Delhi (India) during the summer season using gas-chromatography–quadrupole time-of-flight mass spectrometry (GC-Q-TOF-MS). The mean concentration of particles less than 2.5 µm (PM2.5) observed in Delhi was 3.6 times higher than in Beijing during the measurement period in both the daytime and night-time. In Beijing, the mean concentration of the sum of the 17 PAHs (P17 PAHs) was 8.2 ± 5.1 ng m−3 in daytime, with the highest contribution from indeno[1,2,3-cd]pyrene (12 %), while at nighttime the total PAHs was 7.2 ± 2.0 ng m−3, with the largest contribution from benzo[b]fluoranthene (14 %). In Delhi, the mean P17 PAHs was 13.6 ± 5.9 ng m−3 in daytime and 22.7 ± 9.4 ng m−3 at night-time, with the largest contribution from indeno[1,2,3-cd]pyrene in both the day (17 %) and night (20 %). Elevated mean concentrations of total PAHs in Delhi observed at night were attributed to emissions from vehicles and biomass burning and to meteorological conditions leading to their accumulation from a stable and low atmospheric boundary layer. Local emission sources were typically identified as the major contributors to total measured PAHs in both cities. Major emission sources were characterized based on the contribution from each class of PAHs, with the four-, five- and six-ring PAHs accounting ∼ 95 % of the total PM2.5-bound PAHs mass in both locations. The high contribution of five-ring PAHs to total PAH concentration in summer Beijing and Delhi suggests a high contribution from petroleum combustion. In Delhi, a high contribution from six-ring PAHs was observed at night, suggesting a potential emission source from the combustion of fuel and oil in power generators, widely used in Delhi. The lifetime excess lung cancer risk (LECR) was calculated for Beijing and Delhi, with the highest estimated risk attributed to Delhi (LECR = 155 per million people), which is 2.2 times higher than the Beijing risk assessment value (LECR = 70 per million people). Finally, we have assessed the emission control policies in each city and identified those major sectors that could be subject to mitigation measures

    Validation of time-resolved, automated peak trans-mitral velocity tracking: Two center four-dimensional flow cardiovascular magnetic resonance study

    Get PDF
    Objective: We aim to validate four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) peak velocity tracking methods for measuring the peak velocity of mitral inflow against Doppler echocardiography.  Method: Fifty patients were recruited who had 4D flow CMR and Doppler Echocardiography. After transvalvular flow segmentation using established valve tracking methods, peak velocity was automatically derived using three-dimensional streamlines of transvalvular flow. In addition, a static planar method was used at the tip of mitral valve to mimic Doppler technique.  Results: Peak E-wave mitral inflow velocity was comparable between TTE and the novel 4D flow automated dynamic method (1.02±0.41 m/s vs 1.02±0.36 m/s; P=0.77) however there was a statistically significant difference when compared with the static planar method (0.93±0.37 m/s; P=0.04). Mean A-wave peak velocity was also comparable across TTE and the automated dynamic streamline (0.87±0.39 m/s vs 0.87±0.36 m/s; P=0.99). A significant difference was seen with the static planar method (0.78±0.36 m/s; P=0.04). E/A ratio was comparable between TTE and both the automated dynamic and static planar method (1.22±0.52 vs 1.20±0.34; p=0.76 and 1.36±0.81; p=0.25 respectively). Both novel 4D flow methods showed good correlation with TTE for E-wave (dynamic method; r=0.70; P<0.001 and static planar method; r=0.67; P<0.001) and A-wave velocity measurements (dynamic method; r=0.83; P<0.001 and static method; r=0.71; P<0.001). The automated dynamic method demonstrated excellent intra/inter-observer reproducibility for all parameters.  Conclusion: Automated dynamic peak velocity tracing method using 4D flow CMR is comparable to Doppler echocardiography for mitral inflow assessment and has excellent reproducibility for clinical use

    Development and validation of AI-derived segmentation of four-chamber cine cardiac magnetic resonance

    Get PDF
    Background: Cardiac magnetic resonance (CMR) in the four-chamber plane offers comprehensive insight into the volumetrics of the heart. We aimed to develop an artificial intelligence (AI) model of time-resolved segmentation using the four-chamber cine.   Methods: A fully automated deep learning algorithm was trained using retrospective multicentre and multivendor data of 814 subjects. Validation, reproducibility, and mortality prediction were evaluated on an independent cohort of 101 subjects.   Results: The mean age of the validation cohort was 54 years, and 66 (65%) were males. Left and right heart parameters demonstrated strong correlations between automated and manual analysis, with a ρ of 0.91−0.98 and 0.89−0.98, respectively, with minimal bias. All AI four-chamber volumetrics in repeatability analysis demonstrated high correlation (ρ = 0.99−1.00) and no bias. Automated four-chamber analysis underestimated both left ventricular (LV) and right ventricular (RV) volumes compared to ground-truth short-axis cine analysis. Two correction factors for LV and RV four-chamber analysis were proposed based on systematic bias. After applying the correction factors, a strong correlation and minimal bias for LV volumetrics were observed. During a mean follow-up period of 6.75 years, 16 patients died. On stepwise multivariable analysis, left atrial ejection fraction demonstrated an independent association with death in both manual (hazard ratio (HR) = 0.96, p = 0.003) and AI analyses (HR = 0.96, p < 0.001).   Conclusion: Fully automated four-chamber CMR is feasible, reproducible, and has the same real-world prognostic value as manual analysis. LV volumes by four-chamber segmentation were comparable to short-axis volumetric assessment

    Cholangiocyte organoids can repair bile ducts after transplantation in the human liver.

    Get PDF
    Organoid technology holds great promise for regenerative medicine but has not yet been applied to humans. We address this challenge using cholangiocyte organoids in the context of cholangiopathies, which represent a key reason for liver transplantation. Using single-cell RNA sequencing, we show that primary human cholangiocytes display transcriptional diversity that is lost in organoid culture. However, cholangiocyte organoids remain plastic and resume their in vivo signatures when transplanted back in the biliary tree. We then utilize a model of cell engraftment in human livers undergoing ex vivo normothermic perfusion to demonstrate that this property allows extrahepatic organoids to repair human intrahepatic ducts after transplantation. Our results provide proof of principle that cholangiocyte organoids can be used to repair human biliary epithelium
    corecore