9,477 research outputs found

    A double junction model of irradiated silicon pixel sensors for LHC

    Get PDF
    In this paper we discuss the measurement of charge collection in irradiated silicon pixel sensors and the comparison with a detailed simulation. The simulation implements a model of radiation damage by including two defect levels with opposite charge states and trapping of charge carriers. The modeling proves that a doubly peaked electric field generated by the two defect levels is necessary to describe the data and excludes a description based on acceptor defects uniformly distributed across the sensor bulk. In addition, the dependence of trap concentrations upon fluence is established by comparing the measured and simulated profiles at several fluences and bias voltages.Comment: Talk presented at the 10th European Symposium on Semiconductor Detectors, June 12-16 2005, Wildbad Kreuth, Germany. 9 pages, 4 figure

    The optimal polarizations for achieving maximum contrast in radar images

    Get PDF
    There is considerable interest in determining the optimal polarizations that maximize contrast between two scattering classes in polarimetric radar images. A systematic approach is presented for obtaining the optimal polarimetric matched filter, i.e., that filter which produces maximum contrast between two scattering classes. The maximization procedure involves solving an eigenvalue problem where the eigenvector corresponding to the maximum contrast ratio is an optimal polarimetric matched filter. To exhibit the physical significance of this filter, it is transformed into its associated transmitting and receiving polarization states, written in terms of horizontal and vertical vector components. For the special case where the transmitting polarization is fixed, the receiving polarization which maximizes the contrast ratio is also obtained. Polarimetric filtering is then applies to synthetic aperture radar images obtained from the Jet Propulsion Laboratory. It is shown, both numerically and through the use of radar imagery, that maximum image contrast can be realized when data is processed with the optimal polarimeter matched filter

    Position Dependence of Charge Collection in Prototype Sensors for the CMS Pixel Detector

    Get PDF
    This paper reports on the sensor R&D activity for the CMS pixel detector. Devices featuring several design and technology options have been irradiated up to a proton fluencec of 1E15 n_eq/cm**2 at the CERN PS. Afterward they were bump bonded to unirradiated readout chips and tested using high energy pions in the H2 beam line of the CERN SPS. The readout chip allows a non zero suppressed full analogue readout and therefore a good characterization of the sensors in terms of noise and charge collection properties. The position dependence of signal is presented and the differences between the two sensor options are discussed.Comment: Contribution to the IEEE-NSS Oct. 2003, Portland, OR, USA, submitted to IEEE-TNS 7 pages, 8 figures, 1 table. Revised, title change

    Lattice-dynamics of a Disordered solid-solid Interface

    Full text link
    Generic properties of elastic phonon transport at a disordered interface are studied. The results show that phonon transmittance is a strong function of frequency and the disorder correlation length. At frequencies lower than the van Hove singularity the transmittance at a given frequency increases as the correlation length decreases. At low frequencies, this is reflected by different power-laws for phonon conductance across correlated and uncorrelated disordered interfaces which are in approximate agreement with perturbation theory of an elastic continuum. These results can be understood in terms of simple mosaic and two-colour models of the interface.Comment: 17 pages, 5 figures, submitted to PR

    Reference Standards for Body Fat Measure Using GE Dual Energy X-Ray Absorptiometry in Caucasian Adults

    Full text link
    Background Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesityrelated health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. Objective To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. Methods A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University\u27s Clinical Exercise Physiology Laboratory and University of Wisconsin- Milwaukee\u27s Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Results Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10- year age groups. Women had higher (p\u3c0.01) mean %BF and FMI than men, whereas men had higher (p\u3c0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women

    Leveraging OpenStack and Ceph for a Controlled-Access Data Cloud

    Full text link
    While traditional HPC has and continues to satisfy most workflows, a new generation of researchers has emerged looking for sophisticated, scalable, on-demand, and self-service control of compute infrastructure in a cloud-like environment. Many also seek safe harbors to operate on or store sensitive and/or controlled-access data in a high capacity environment. To cater to these modern users, the Minnesota Supercomputing Institute designed and deployed Stratus, a locally-hosted cloud environment powered by the OpenStack platform, and backed by Ceph storage. The subscription-based service complements existing HPC systems by satisfying the following unmet needs of our users: a) on-demand availability of compute resources, b) long-running jobs (i.e., >30> 30 days), c) container-based computing with Docker, and d) adequate security controls to comply with controlled-access data requirements. This document provides an in-depth look at the design of Stratus with respect to security and compliance with the NIH's controlled-access data policy. Emphasis is placed on lessons learned while integrating OpenStack and Ceph features into a so-called "walled garden", and how those technologies influenced the security design. Many features of Stratus, including tiered secure storage with the introduction of a controlled-access data "cache", fault-tolerant live-migrations, and fully integrated two-factor authentication, depend on recent OpenStack and Ceph features.Comment: 7 pages, 5 figures, PEARC '18: Practice and Experience in Advanced Research Computing, July 22--26, 2018, Pittsburgh, PA, US

    Polarimetric clutter modeling: Theory and application

    Get PDF
    The two-layer anisotropic random medium model is used to investigate fully polarimetric scattering properties of earth terrain media. The polarization covariance matrices for the untilted and tilted uniaxial random medium are evaluated using the strong fluctuation theory and distorted Born approximation. In order to account for the azimuthal randomness in the growth direction of leaves in tree and grass fields, an averaging scheme over the azimuthal direction is also applied. It is found that characteristics of terrain clutter can be identified through the analysis of each element of the covariance matrix. Theoretical results are illustrated by the comparison with experimental data provided by MIT Lincoln Laboratory for tree and grass fields

    Extraction of electric field in heavily irradiated silicon pixel sensors

    Full text link
    A new method for the extraction of the electric field in the bulk of heavily irradiated silicon pixel sensors is presented. It is based on the measurement of the Lorentz deflection and mobility of electrons as a function of depth. The measurements were made at the CERN H2 beam line, with the beam at a shallow angle with respect to the pixel sensor surface. The extracted electric field is used to simulate the charge collection and the Lorentz deflection in the pixel sensor. The simulated charge collection and the Lorentz deflection is in good agreement with the measurements both for non-irradiated and irradiated up to 1E15 neq/cm2 sensors.Comment: 6 pages, 11 figures, presented at the 13th International Workshop on Vertex Detectors for High Energy Physics, September 13-18, 2004, Menaggio-Como, Italy. Submitted to Nucl. Instr. Meth.
    corecore