114 research outputs found

    Visual Attention toward Human Face Recognizing for Autism Spectrum Disorder and Normal Developing Children: An Eye Tracking Study

    Get PDF
    © 2020 ACM. The paper discusses an eye tracking analysis study to let us understand the visual behavior and pattern of Normal Developing children and Autistic children while viewing human face stimulus. An eye tracking experiment consists of displaying different images with human face embedded in different locations (left, center and right) and the eye tracker captured and tracked the child\u27s eye gaze movements, then analyzed to identify where specifically in the stimulus is the child looking at. The finding indicates a significant difference was found between the two groups viewing patterns and behavior when they presented with a scene that have human face. The study also reveals that large percentage of Autistic participants expressed minimum interest and time looking at face area, evident by significant time spent fixations on non-face regions, comparing to the normal developing children. The results can be used to improve the life style of other children who have a risk to develop Autism as well as discover earlier signs of ASD

    Patterns of Retinal Damage Facilitate Differential Diagnosis between Susac Syndrome and MS

    Get PDF
    Susac syndrome, a rare but probably underdiagnosed combination of encephalopathy, hearing loss, and visual deficits due to branch retinal artery occlusion of unknown aetiology has to be considered as differential diagnosis in various conditions. Particularly, differentiation from multiple sclerosis is often challenging since both clinical presentation and diagnostic findings may overlap. Optical coherence tomography is a powerful and easy to perform diagnostic tool to analyse the morphological integrity of retinal structures and is increasingly established to depict characteristic patterns of retinal pathology in multiple sclerosis. Against this background we hypothesised that differential patterns of retinal pathology facilitate a reliable differentiation between Susac syndrome and multiple sclerosis. In this multicenter cross-sectional observational study optical coherence tomography was performed in nine patients with a definite diagnosis of Susac syndrome. Data were compared with age-, sex-, and disease duration-matched relapsing remitting multiple sclerosis patients with and without a history of optic neuritis, and with healthy controls. Using generalised estimating equation models, Susac patients showed a significant reduction in either or both retinal nerve fibre layer thickness and total macular volume in comparison to both healthy controls and relapsing remitting multiple sclerosis patients. However, in contrast to the multiple sclerosis patients this reduction was not distributed over the entire scanning area but showed a distinct sectorial loss especially in the macular measurements. We therefore conclude that patients with Susac syndrome show distinct abnormalities in optical coherence tomography in comparison to multiple sclerosis patients. These findings recommend optical coherence tomography as a promising tool for differentiating Susac syndrome from MS

    Universal high work function flexible anode for simplified ITO-free organic and perovskite light-emitting diodes with ultra-high efficiency

    Get PDF
    Flexible transparent electrode materials such as conducting polymers, silver nanowires, carbon nanotubes and graphenes are being investigated as possible replacements for conventional brittle inorganic electrodes. However, they have critical drawbacks of low work function (WF), resulting in a high hole injection barrier to an overlying semiconducting layer in simplified organic or organic-inorganic hybrid perovskite light-emitting diodes (OLEDs or PeLEDs). Here, we report a new anode material (AnoHIL) that has multifunction of both an anode and a hole injection layer (HIL) as a single layer. The AnoHIL has easy WF tunability up to 5.8 eV and thus makes ohmic contact without any HIL. We applied our anodes to simplified OLEDs, resulting in very high efficiency (62% ph el(-1) for single and 88% ph el(-1) for tandem). The AnoHIL showed a similar tendency in simplified PeLEDs, implying universal applicability to various optoelectronics. We also demonstrated large-area flexible lightings using our anodes. Our results provide a significant step toward the next generation of high-performance simplified indium tin oxide (ITO)-free light-emitting diodes.

    Predicting creditworthiness in retail banking with limited scoring data

    Get PDF
    The preoccupation with modelling credit scoring systems including their relevance to predicting and decision making in the financial sector has been with developed countries, whilst developing countries have been largely neglected. The focus of our investigation is on the Cameroonian banking sector with implications for fellow members of the Banque des Etats de L'Afrique Centrale (BEAC) family which apply the same system. We apply logistic regression (LR), Classification and Regression Tree (CART) and Cascade Correlation Neural Network (CCNN) in building our knowledge-based scoring models. To compare various models’ performances, we use ROC curves and Gini coefficients as evaluation criteria and the Kolmogorov-Smirnov curve as a robustness test. The results demonstrate that an improvement in terms of predicting power from 15.69% default cases under the current system, to 7.68% based on the best scoring model, namely CCNN can be achieved. The predictive capabilities of all models are rated as at least very good using the Gini coefficient; and rated excellent using the ROC curve for CCNN. Our robustness test confirmed these results. It should be emphasised that in terms of prediction rate, CCNN is superior to the other techniques investigated in this paper. Also, a sensitivity analysis of the variables identifies previous occupation, borrower's account functioning, guarantees, other loans and monthly expenses as key variables in the forecasting and decision making processes which are at the heart of overall credit policy

    Magnetic source localization of early visual mismatch response

    No full text
    Previous studies have reported a visual analogue of the auditory mismatch negativity (MMN) response that is based on sensory memory. The neural generators and attention dependence of the visual MMN (vMMN) still remain unclear. We used magnetoencephalography (MEG) and spatio-temporal source localization to determine the generators of the sensory-memory-based vMMN response to non-attended deviants. Ten participants were asked to discriminate between odd and even digits presented at the center of the visual field while grating patterns with different spatial frequencies were presented outside the focus of attention. vMMN was calculated as the difference between MEG responses to infrequent gratings in oddball blocks and the same gratings in equiprobable blocks. The peak latency of the vMMN response was between 100 and 160 ms. The neuromagnetic sources of the vMMN localized in the occipital cortex differed from the sources evoked by the equiprobable gratings and were stimulus-dependent. Our results suggest the existence of separate neural systems for pre-attentive memory-based detection of visual change and provide new evidence that the vMMN is feature-specific. © 2013 Springer Science+Business Media

    Foetal Radiation Dose During Prophylactic Occlusion Balloon Placement for Morbidly Adherent Placenta

    No full text
    Objective To assess foetal absorbed radiation dose (FAD) during prophylactic occlusion balloon catheter (POBC) placement before surgery for morbidly adherent placenta (MAP). Methods Retrospective cohort study of women with MAP undergoing POBC before surgery. Women were divided into two groups. Group 1 treated between 2008 and 2011, Group 2 between 2012 and 2014 when fluoroscopy pulse rate reduced from 7.5 to 2 pulses per second. Median and interquartile range (IQR) of dose area product (DAP) and FAD were compared using the Mann-U-Whitney test. FAD was calculated using the PCXMC Monte-Carlo calculation. All procedures were performed using the same equipment (Siemens Axiom Artis dTA) by the same experienced interventional radiology team. Results Thirty-four women underwent POBC. 16 procedures were performed in Group 1 and 18 in Group 2. Median DAP overall was 1025.10 lGym2 (IQR 532.1–1775.3): Group 1, 1713.25 lGym2 (IQR 1164.5–2274.5) and Group 2, 660.70 lGym2 (IQR 440.9–1020.9) (p= 0.027). Median FAD overall was 4.65 mGy (IQR 2.7–8.2): Group 1, 6.25 mGy (IQR 4.4–10.6) and Group 2, 3.05 mGy (IQR 2.0–5.4) (p= 0.031). Conclusions FAD during POBC insertion is low overall. The only change between the two groups was in pulsed fluoroscopy rate which resulted in a significant reduction in FAD. This reinforces the importance of implementation of dose reduction techniques
    corecore