872 research outputs found

    The European Large Area ISO Survey - ISOPHOT results using the MPIA-pipeline

    Get PDF
    The European Large Area ISO Survey (ELAIS) will provide Infrared observations of 4 regions in the sky with ISO. Around 2000 Infrared sources have been detected at 7 and 15 microns (with ISOCAM), 90 and 175 microns (with ISOPHOT)) over 13 square degrees of the sky. We present the source extraction pipeline of the 90 microns ISOPHOT observations, describe and discuss the results obtained and derive the limits of the ELAIS observational strategy.Comment: 4 pages, 5 figures, to appear in the ISO conference "The Universe as seen by ISO", 1998, UNESCO, Pari

    A Multiwavelength Study of a Sample of 70 ÎŒm Selected Galaxies in the COSMOS Field. II. The Role of Mergers in Galaxy Evolution

    Get PDF
    We analyze the morphological properties of a large sample of 1503 70 ÎŒm selected galaxies in the COSMOS field spanning the redshift range 0.01 10^(12) L_☉) being up to ~50%. We also find that the fraction of spirals drops dramatically with L_(IR). Minor mergers likely play a role in boosting the infrared luminosity for sources with low luminosities (L_(IR) 1 being difficult to classify and subject to the effects of bandpass shifting; therefore, these numbers can only be considered lower limits. At z 1, the fraction of major mergers is lower, but is at least 30%-40% for ULIRGs. In a comparison of our visual classifications with several automated classification techniques we find general agreement; however, the fraction of identified mergers is underestimated due to automated classification methods being sensitive to only certain timescales of a major merger. Although the general morphological trends agree with what has been observed for local (U)LIRGs, the fraction of major mergers is slightly lower than seen locally. This is in part due to the difficulty of identifying merger signatures at high redshift. The distribution of the U – V color of the galaxies in our sample peaks in the green valley (= 1.1) with a large spread at bluer and redder colors and with the major mergers peaking more strongly in the green valley than the rest of the morphological classes. We argue that, given the number of major gas-rich mergers observed and the relatively short timescale that they would be observable in the (U)LIRG phase, it is plausible for the observed red sequence of massive ellipticals (<10^(12) M_☉) to have been formed entirely by gas-rich major mergers

    Femoral revision with the modular ZMR stem. Clinical and x-rays results at medium term follow-up

    Get PDF
    A retrospective review was conducted to evaluate the medium-term results of the ZMR modular revision taper stem. From March 1999 to December 2002, 65 consecutive hip revision surgeries were performed mostly for aseptic loosening. Femoral bone stock defects were classified according to AAOS\u2019s criteria and consisted mainly in type II and type III. A Wagner osteotomy was performed in 25 cases to remove primary implants that were cemented in 35 cases. Mean post-operative follow-up was 69 months (range, 36 to 91months). Clinical assessment at follow-up showed a significantly improved mean Harris Hip Score from 42 points preoperatively to 81 points postoperatively, while the x-ray examination did show a satisfactory distal integration of the stem in all cases and satisfactory reconstitution of the femoral bone stock in 47% of cases. The average subsidence of the stem at follow-up was under one millimeter. According to the data leg length discrepancy exceeding 15 millimeters caused significantly higher functional impairment and more pain

    Lateral parapatellar approach in primary total knee arthroplasty of the valgus knee

    Get PDF
    Background Anatomic and pathological characteristics of the valgus knee deformity represent a challenging issue for the implant of a total knee arthroplasty. The surgical approach in such cases should allow a direct ad easy exposure of the joint, easy lateral soft tissue balancing and adequate patellar tracking. Materials and Methods Twenty-four total knee arthroplasties were implanted in valgus knees between January 2002 and September 2005. A mean preoperative valgus deformity of 18\ub0 was assessed on standing x-rays. Four posterior stabilized, eighteen posterior stabilized rotating platform prosthesis and two superstabilized prosthesis were implanted in 21 patients. The surgical approach has been in all cases a lateral parapatellectomy. Follow-up assessments were obtained for all patients at a mean 23 months. They consisted of a Knee Society Score and a Patellar Score evaluation, standing AP and lateral radiograms and skyline x-rays obtained at a flection of 45\ub0. Results A mean preoperative Knee Society Clinical Score of 32,7 points (range, -4 to 64 points) significantly improved at follow-up to an average 88,8 points (range, 57 to 99 points; p<0,05). The Knee Society Function Score significantly increased from a preoperative mean score of 32,7 points (range, -20 to 75 points) to an average followup score of 81,2 points (range, 30 to 100 points; p<0.05). The Patella Score revealed absence of anterior pain in all cases but one that reported severe pain. A satisfactory patello-femoral alignement of 4.7\ub0 (range, 1\ub0 to 10\ub0) was obtained at last follow-up x-rays. One intraoperative condilar fracture occured and was treated with a single screw. Discussion The lateral approach of valgus knees led to satisfactory results in primary total knee arthroplasties in a percentage of cases comparable or superior to those presented in literature for different approaches. In addition, lateral release is performed as a part of the approach itself, allows preservation of the blood supplies of the extensor apparatus and an optimal patellar tracking in most cases. Conclusions In conclusion, the lateral approach for a primary total knee arthroplasty could be recommended in valgus knees affected by osteoarthritis because as it proved to be effective in achieving a satisfactory implant positioning and functional outcome while reporting minor complications

    Treatment of periprosthetic femoral fractures with distal fixation modular revision stems

    Get PDF
    Background Late periprosthetic fractures of the femur are the third most frequently reported cause of surgery after total hip artroplasty. Revision total hip artroplasty can be difficult, especially when poor bone stock is encountered. The aim of this study was to examine the results of late periprosthetic fractures complicated with primary implant loosening performed with distal fixation modular revision stem. Methods From November 1999 to May 2006, 16 late periprosthetic fractures were treated with distal-fixation, modular, straight stem. There were 13 females (82%) and 3 males (18%) whose mean age at surgery was 76.7 years (range, 48 to 95 years). Femoral revision surgery was performed with the Revitan (2 cases) and ZMR (14 cases) to get a stable distal primary fixation. X-rays were assessed accordingly to the Vancouver classification: there were 3 type B2 and 13 type B3 fractures. Mean post-operative follow-up was 52 months (range, 10 to 88 months). At the time of the last follow-up visit 4 patients already passed away, all of them for causes unrelated to the procedure. The clinical outcome was monitored with the Harris Hip Score, subjective VAS, pain and satisfaction evaluation. Standard AP and lateral x-rays of the hip were obtained at each follow-up visit. Leg-length discrepancy was also investigated as a factor possibly affecting outcome. Complications included one septic loosening that was treated with a two-stage revision. Results All the patients but one were finally able to walk and had minimal to no pain at all. A satisfactory functional outcome was achieved with an average 76 (range, 25 to 100) Harris Hip Scores points. The subjective pain and satisfaction scores were respectively 2.4 and 7.8 points. As far as radiograms are concerned, all the sixteen femur did show a good healing of the fracture, with no secondary stem subsidence. Discussion Generally, considering the severity of an event such as a periprosthetic late fracture in an elderly patient, results were satisfactory. The average Harris Hip Score and subjective satisfaction would have been even higher if one patient wouldn\u2019t have been so much disappointed because of her severe leg-length discrepancy, dependent on the acetabular side. From a surgical point of view, the employed devices proved to be handy in bridging the fracture with distal fixation while adequately stabilizing it. Conclusions According to the reported results, straight modular-revison stems provide an adequate treatment option of Vancouver type B3 and in selected cases of B2 type periprosthetic femoral fracture

    Optical/Near-Infrared Imaging of Infrared-Excess Palomar-Green QSOs

    Get PDF
    Ground-based high spatial-resolution (FWHM < 0.3-0.8") optical and near-infrared imaging (0.4-2.2um) is presented for a complete sample of optically selected Palomar-Green QSOs with far-infrared excesses at least as great as those of "warm" AGN-like ultraluminous infrared galaxies (L_ir/L_big-blue-bump > 0.46). In all cases, the host galaxies of the QSOs were detected and most have discernable two-dimensional structure. The QSO host galaxies and the QSO nuclei are similar in magnitude at H-band. H-band luminosities of the hosts range from 0.5-7.5 L* with a mean of 2.3 L*, and are consistent with those found in ULIGs. Both the QSO nuclei and the host galaxies have near-infrared excesses, which may be the result of dust associated with the nucleus and of recent dusty star formation in the host. These results suggest that some, but not all, optically-selected QSOs may have evolved from an infrared-active state triggered by the merger of two similarly-sized L* galaxies, in a manner similar to that of the ultraluminous infrared galaxies.Comment: Aastex format, 38 pages, 4 tables, 10 figures. Higher quality figures are available in JPG forma

    Initial experience with Vanguard(R) total knee arthroplasty

    Get PDF
    Introduction Biomet Vanguard(R) Complete Knee System is a total knee replacement system, introduced into the market in 2003: thissystem boasts a designed kneecap track or groove which allows for greater mobility and decreased loss of healthy bone during the replacement process. Clinical and radiographic results in Varese Orthopaedics Unit initial experience are reported. Materials and methods Clinical and radiographic parameters are evaluated in 29 patients who underwent TKA (Vanguard(R) Complete Knee System- Biomet Inc.) for primary gonarthrosis during the last 2 years at Orthopaedics and Traumatology Unit of Ospedale di Circolo\u2014Fondazione Macchi in Varese. ROM, type of anaesthesia, patellar pain, clinical and functional Knee Score (pre-operative), size of implant, ROM, blooding, patellar pain, VAS, clinical and func- tional Knee Score (post-operative) are analyzed. Radiographic follow-up is made at 6 and 12 months. Results Clinical and Functional Knee Score respectively improve from 47 to 88 pts and from 51 to 88 pts in pre- and post-operative period (p\0.001). Post-operatively no patellar pain, 2 pts VAS and 1215 cc blooding are reported. ROM doesn\u2019t significantly improve from pre- to post-operative. No relevant complications are reported. Due to the short follow-up, radiographic evaluation does not allow to demonstrate polyethylene liner wear. Conclusions Vanguard(R) Knee Replacement significantly shows a clinical and functional improvement in patients affected by primary gonarthrosis. Moreover, post-operative pain decrease allows early mobilization and rehabilitation

    Spatially Resolved Spitzer-IRS Spectral Maps of the Superwind in M82

    Get PDF
    We have mapped the superwind/halo region of the nearby starburst galaxy M82 in the mid-infrared with Spitzer−IRSSpitzer-IRS. The spectral regions covered include the H2S(1)−S(3)_2 S(1)-S(3), [NeII], [NeIII] emission lines and PAH features. We estimate the total warm H2_2 mass and the kinetic energy of the outflowing warm molecular gas to be between Mwarm∌5−17×106M_{warm}\sim5-17\times10^6 M⊙_{\odot} and EK∌6−20×1053E_{K}\sim6-20\times10^{53} erg. Using the ratios of the 6.2, 7.7 and 11.3 micron PAH features in the IRS spectra, we are able to estimate the average size and ionization state of the small grains in the superwind. There are large variations in the PAH flux ratios throughout the outflow. The 11.3/7.7 and the 6.2/7.7 PAH ratios both vary by more than a factor of five across the wind region. The Northern part of the wind has a significant population of PAH's with smaller 6.2/7.7 ratios than either the starburst disk or the Southern wind, indicating that on average, PAH emitters are larger and more ionized. The warm molecular gas to PAH flux ratios (H2/PAH_2/PAH) are enhanced in the outflow by factors of 10-100 as compared to the starburst disk. This enhancement in the H2/PAH_2/PAH ratio does not seem to follow the ionization of the atomic gas (as measured with the [NeIII]/[NeII] line flux ratio) in the outflow. This suggests that much of the warm H2_2 in the outflow is excited by shocks. The observed H2_2 line intensities can be reproduced with low velocity shocks (v<40v < 40 km s−1^{-1}) driven into moderately dense molecular gas (102<nH<10410^2 <n_H < 10^4 cm−3^{-3}) entrained in the outflow.Comment: 19 pages and 12 figures; accepted in MNRA

    An Experimental Validation of Phase-Based Motion Magnification for Structures with Developing Cracks and Time-Varying Configurations

    Get PDF
    In this study, Computer Vision and Phase-Based Motion Magnification (PBMM) are validated for continuous Structural Health Monitoring (SHM) purposes. The aim is to identify the exact instant of occurrence for damage or abrupt structural changes from video-extracted, very low amplitude (barely visible) vibrations. The study presents three experimental datasets: a box beam with multiple saw cuts of different lengths and angles, a beam with a full rectangular cross section and a mass added at the tip, and the spar of a prototype High-Aspect-Ratio wing. Both mode-shape- and frequency-based approaches are considered, showing the potential to identify the severity and position of the damage as well A high-definition, high-speed camera and a low-cost commercial alternative have been successfully utilised for these video acquisitions. Finally, the technique is also preliminarily tested for outdoor applications with smartphone cameras
    • 

    corecore