169 research outputs found

    Modulated-laser source induction system for remote detection of infrared emissions of high explosives using laser-induced thermal emission

    Get PDF
    In a homeland security setting, the ability to detect explosives at a distance is a top security priority. Consequently, the development of remote, noncontact detection systems continues to represent a path forward. In this vein, a remote detection system for excitation of infrared emissions using a CO2 laser for generating laser-induced thermal emission (LITE) is a possible solution. However, a LITE system using a CO2 laser has certain limitations, such as the requirement of careful alignment, interference by the CO2 signal during detection, and the power density loss due to the increase of the laser image at the sample plane with the detection distance. A remote chopped-laser induction system for LITE detection using a CO2 laser source coupled to a focusing telescope was built to solve some of these limitations. Samples of fixed surface concentration (500 ÎŒg∕cm2) of 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) were used for the remote detection experiments at distances ranging between 4 and 8 m. This system was capable of thermally exciting and capturing the thermal emissions (TEs) at different times in a cyclic manner by a Fourier transform infrared (FTIR) spectrometer coupled to a gold-coated reflection optics telescope (FTIR-GT). This was done using a wheel blocking the capture of TE by the FTIR-GT chopper while heating the sample with the CO2 laser. As the wheel moved, it blocked the CO2 laser and allowed the spectroscopic system to capture the TEs of RDX. Different periods (or frequencies) of wheel spin and FTIR-GT integration times were evaluated to find dependence with observation distance of the maximum intensity detection, minimum signal-to-noise ratio, CO2 laser spot size increase, and the induced temperature incremen

    Mid-Infrared Laser Spectroscopy Applications I: Detection of Traces of High Explosives on Reflective and Matte Substrates

    Get PDF
    Mid-infrared (MIR) lasers have revolutionized infrared vibrational spectroscopy, converting an already dominant spectroscopic analysis technique into an even more powerful, easier to use, and quicker turn-around cadre of versatile spectroscopic tools. A selection of applications, revisited under the umbrella of MIR laser-based properties, very high brightness, collimated beams, polarized sources, highly monochromatic tunable sources, and coherent sources, is included. Applications discussed concern enhanced detection, discrimination, and quantification of high explosives (HEs). From reflectance measurements of chemical residues on highly reflective metallic substrates to reflectance measurements of HEs deposited on non-reflective, matte substrates is discussed. Coupling with multivariate analyses (MVA) techniques of Chemometrics allowed near trace detection of HEs, with sharp discrimination from highly MIR absorbing substrates

    Mid-Infrared Laser Spectroscopy Applications in Process Analytical Technology: Cleaning Validation, Microorganisms, and Active Pharmaceutical Ingredients in Formulations

    Get PDF
    Mid-infrared (MIR) lasers are very high-brightness energy sources that are replacing conventional thermal sources (globars) in many infrared spectroscopy (IRS) techniques. Although not all laser properties have been exploited in depth, properties such as collimation, polarization, high brightness, and very high resolution have contributed to recast IRS tools. Applications of MIR laser spectroscopy to process analytical technology (PAT) are numerous and important. As an example, a compact grazing angle probe mount has allowed coupling to a MIR quantum cascade laser (QCL), enabling reflectance-absorbance infrared spectroscopy (RAIRS) measurements. This methodology, coupled to powerful multivariable analysis (MVA) routines of chemometrics and fast Fourier transform (FFT) preprocessing of the data resulted in very low limits of detection of active pharmaceutical ingredients (APIs) and high explosives (HEs) reaching trace levels. This methodology can be used to measure concentrations of surface contaminants for validation of cleanliness of pharmaceutical and biotechnology processing batch reactors and other manufacturing vessels. Another application discussed concerns the enhanced detection of microorganisms that can be encountered in pharmaceutical and biotechnology plants as contaminants and that could also be used as weapons of mass destruction in biological warfare. In the last application discussed, the concentration of APIs in formulations was determined by MIR laser spectroscopy and was cross validated with high-performance liquid chromatography

    Evaluation of macular retinal ganglion cell-inner plexiform layer thickness after vitrectomy with internal limiting membrane peeling for idiopathic macular holes

    Get PDF
    Purpose. To evaluate macular retinal ganglion cell-inner plexiform layer (GCIPL) thickness changes after Brilliant Blue G-assisted internal limiting membrane peeling for idiopathic macular hole repair using a high-resolution spectral-domain optical coherence tomography (SD-OCT). Methods. 32 eyes from 32 patients with idiopathic macular holes who underwent vitrectomy with internal limiting membrane peeling between January 2011 and July 2012 were retrospectively analyzed. GCIPL thickness was measured before surgery, and at one month and at six months after surgery. Values obtained from automated and semimanual SD-OCT segmentation analysis were compared (Cirrus HD-OCT, Carl Zeiss Meditec, Dublin, CA). Results. No significant differences were found between average GCIPL thickness values between preoperative and postoperative analysis. However, statistical significant differences were found in GCIPL thickness at the temporal macular quadrants at six months after surgery. Quality measurement analysis performed by automated segmentation revealed a significant number of segmentation errors. Semimanual segmentation slightly improved the quality of the results. Conclusion. SD-OCT analysis of GCIPL thickness found a significant reduction at the temporal macular quadrants at 6 months after Brilliant Blue G-assisted internal limiting membrane peeling for idiopathic macular hole

    11th International Conference on Practical Applications of Agents and Multi-Agent Systems

    Get PDF
    Research on Agents and Multi-agent Systems has matured during the last decade and many effective applications of this technology are now deployed. PAAMS provides an international forum to presents and discuss the latest scientific developments and their effective applications, to assess the impact of the approach, and to facilitate technology transfer. PAAMS started as a local initiative, but since grown to become the international yearly platform to present, to discuss, and to disseminate the latest developments and the most important outcomes related to real-world applications. It provides a unique opportunity to bring multi-disciplinary experts, academics and practitioners together to Exchange their experience in the development and deployment of Agents and Multiagents systems. PAAMS intends to bring together researchers and developers from industry and the academic world to report on the latest scientific and technical advances on the application of multi-agent systems, to discuss and debate the major issues, and to showcase the latest systems using agent based technology. It will promote a forum for discussion on how agent based techniques, methods and tools help system designers to accomplish the mapping between available agent technology and application needs. Other stakeholders should be rewarded with a better understanding of the potential and challenges of the agent-oriented approach. This edition of PAAMS special sessions is organized by the Bioinformatics, Intelligent System and Educational Technology Research Group (http://bisite.usal.es) of the University of Salamanca. The present edition was held in Salamanca, Spain, from 22nd to 24th May 2013

    Stress related epigenetic changes may explain opportunistic success in biological invasions in Antipode mussels

    Get PDF
    Different environmental factors could induce epigenetic changes, which are likely involved in the biological invasion process. Some of these factors are driven by humans as, for example, the pollution and deliberate or accidental introductions and others are due to natural conditions such as salinity. In this study, we have analysed the relationship between different stress factors: time in the new location, pollution and salinity with the methylation changes that could be involved in the invasive species tolerance to new environments. For this purpose, we have analysed two different mussels’ species, reciprocally introduced in antipode areas: the Mediterranean blue mussel Mytilus galloprovincialis and the New Zealand pygmy mussel Xenostrobus securis, widely recognized invaders outside their native distribution ranges. The demetylathion was higher in more stressed population, supporting the idea of epigenetic is involved in plasticity process. These results can open a new management protocols, using the epigenetic signals as potential pollution monitoring tool. We could use these epigenetic marks to recognise the invasive status in a population and determine potential biopollutants

    Toxoplasma gondii infection and liver disease: a case-control study in a Northern Mexican population

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Infection with the protozoan parasite <it>Toxoplasma gondii </it>may cause liver disease. However, the impact of the infection in patients suffering from liver disease is unknown. Therefore, through a case-control study design, 75 adult liver disease patients attending a public hospital in Durango City, Mexico, and 150 controls from the general population of the same region matched by gender, age, and residence were examined with enzyme-linked immunoassays for the presence of anti-<it>Toxoplasma </it>IgG and anti-<it>Toxoplasma </it>IgM antibodies. Socio-demographic, clinical and behavioral characteristics from the study subjects were obtained.</p> <p>Results</p> <p>Seroprevalence of anti-<it>Toxoplasma </it>IgG antibodies and IgG titers did not differ significantly in patients (10/75; 13.3%) and controls (16/150; 10.7%). Two (2.7%) patients and 5 (3.3%) controls had anti-<it>Toxoplasma </it>IgM antibodies (<it>P </it>= 0.57). Seropositivity to <it>Toxoplasma </it>did not show any association with the diagnosis of liver disease. In contrast, seropositivity to <it>Toxoplasma </it>in patients was associated with consumption of venison and quail meat. <it>Toxoplasma </it>seropositivity was more frequent in patients with reflex impairment (27.8%) than in patients without this impairment (8.8%) (<it>P </it>= 0.05). Multivariate analysis showed that <it>Toxoplasma </it>seropositivity in patients was associated with consumption of sheep meat (OR = 8.69; 95% CI: 1.02-73.71; <it>P </it>= 0.04) and rabbit meat (OR = 4.61; 95% CI: 1.06-19.98; <it>P </it>= 0.04).</p> <p>Conclusions</p> <p>Seropositivity to <it>Toxoplasma </it>was comparable among liver disease patients and controls. Further studies with larger sample sizes are needed to elucidate the association of <it>Toxoplasma </it>with liver disease. Consumption of venison, and rabbit, sheep, and quail meats may warrant further investigation.</p

    Making Informed Choices about Microarray Data Analysis

    Get PDF
    This article describes the typical stages in the analysis of microarray data for non-specialist researchers in systems biology and medicine. Particular attention is paid to significant data analysis issues that are commonly encountered among practitioners, some of which need wider airing. The issues addressed include experimental design, quality assessment, normalization, and summarization of multiple-probe data. This article is based on the ISMB 2008 tutorial on microarray data analysis. An expanded version of the material in this article and the slides from the tutorial can be found at http://www.people.vcu.edu/~mreimers/OGMDA/index.html
    • 

    corecore