84 research outputs found
72 Multicenter clinical evaluation of the HeartMate II axial flow left ventricular assist device in patients with severe heart failure: hemodynamic effects, pump performance and quality of life
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/106728/1/ehfs80038-x.pd
A review of bronchiolitis obliterans syndrome and therapeutic strategies
Lung transplantation is an important treatment option for patients with advanced lung disease. Survival rates for lung transplant recipients have improved; however, the major obstacle limiting better survival is bronchiolitis obliterans syndrome (BOS). In the last decade, survival after lung retransplantation has improved for transplant recipients with BOS. This manuscript reviews BOS along with the current therapeutic strategies, including recent outcomes for lung retransplantation
Erratum to: 36th International Symposium on Intensive Care and Emergency Medicine
[This corrects the article DOI: 10.1186/s13054-016-1208-6.]
Inhibition of interleukin-6 synthesis in an animal model of septic shock by anti-C5a monoclonal antibodies
The complement activation fragment C5a was recently shown to induce interleukin (IL)-6 synthesis by peripheral blood mononuclear cells. To understand better the role of C5a in cytokine regulation in vivo, we investigated the effects of complement depletion by cobra venom factor (CVF) or of anti-C5a monoclonal antibodies (mAb) on IL-6 generation in an animal model of septic shock. Complement-depleted pigs which were subsequently challenged with Escherichia coli generated significantly (p < 0.05) less IL-6 during the 6-h observation period than complement-sufficient controls. To address specifically the role of C5a in IL-6 regulation, we produced a C5a(57-74) peptide-specific mAb (T13/9) which neutralizes the bioactivity of porcine C5a. The mAb T13/9 does not cross-react with the precursor protein C5. The pretreatment of pigs with anti-C5a mAb T13/9 prior to the induction of sepsis resulted in a decrease of over 75% in serum IL-6 bioactivity compared to control animals (p < 0.0001). These results indicate a role for C5a in the modulation of IL-6 synthesis in Gram-negative bacteremia
Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial
Background: Third-generation rotary blood pumps have magnetically levitated rotors that eliminate mechanical wear over the years. Together with their potential for miniaturization, these pumps seem suitable for long-term support of patients with a wide range of body surface areas (BSA). Recently, the novel HVAD pump (HeartWare Inc, Framingham, MA), a miniaturized centrifugal pump with a hydrodynamic, magnetically levitated rotor, became ready for clinical application.
Methods: In a multi-institutional trial in Europe and Australia, 23 patients (mean age, 47.9 ± 12 years) in end-stage heart failure were enrolled in 5 centers. The primary end point of the bridge-to-transplant study was survival to heart transplant or survival to 180 days on the device, whichever occurred first. Follow-up data at 1 year are presented. The small size of the device allows for intrapericardial placement of the pump.
Results: Implant procedures were generally fast and uneventful. Mean duration of support was 167 ± 143 days (range, 13–425 days), and mean blood flow provided by the pump was 6.1 ± 1.1 liters/min. At the 180-day end point, 2 patients had undergone successful transplant at 157 and 175 days, 2 patients died while on the device, and 19 patients continued pump support for more than 180 days. Actuarial survival after 6 months was 91% and was 86% at the 1-year follow-up.
Conclusions: The design of the HVAD pump enables a quick and less invasive implantation. The results to date demonstrate satisfactory long-term survival with excellent quality of life in this cohort of 23 patients of the initial multi-institutional Conformité Européene (CE) mark trial
Multicenter evaluation of an intrapericardial left ventricular assist system
Objectives: The aim of this study was to conduct an initial clinical evaluation of the new HeartWare Ventricular Assist System (HeartWare, Inc., Framingham, Massachusetts) in a multicenter, prospective, nonrandomized single-arm clinical trial.
Background: Heart failure is a worldwide epidemic. The effectiveness of heart transplantation and medical therapy is limited, resulting in the emergence of mechanical circulatory support as a primary treatment for end-stage heart disease. Left ventricular assist devices that use rotary pumps are small and durable, which might reduce morbidity and mortality during support.
Methods: Fifty heart transplant candidates with New York Heart Association functional class IV symptoms were supported at 5 international centers by the HeartWare System for 180 days, until heart transplant, myocardial recovery and device explant, or death. Patients who continue to be supported have been followed for a minimum of 2 years.
Results: Of the 50 patients, 20 (40%) received transplants, 4 (8%) had the pump explanted after myocardial recovery, and 17 (34%) continue support at 2 years. Nine (18%) patients died during support from sepsis (n = 3), multiple organ failure (n = 3), or hemorrhagic stroke (n = 3). The actual survival at 6, 12, and 24 months was 90%, 84%, and 79%, respectively. In the survivors, measures of quality of life showed a significant improvement over baseline values. Significant improvements were found for recognition memory at 3 months after implant (p = 0.006). The most frequent adverse events were infection and bleeding.
Conclusions: Patients with end-stage heart failure can be safely and effectively supported by the HeartWare Ventricular Assist System with improved quality of life and neurocognitive function
- …