79 research outputs found

    Genetic Variation in OAS1 Is a Risk Factor for Initial Infection with West Nile Virus in Man

    Get PDF
    West Nile virus (WNV) is a re-emerging pathogen that can cause fatal encephalitis. In mice, susceptibility to WNV has been reported to result from a single point mutation in oas1b, which encodes 2′–5′ oligoadenylate synthetase 1b, a member of the type I interferon-regulated OAS gene family involved in viral RNA degradation. In man, the human ortholog of oas1b appears to be OAS1. The ‘A’ allele at SNP rs10774671 of OAS1 has previously been shown to alter splicing of OAS1 and to be associated with reduced OAS activity in PBMCs. Here we show that the frequency of this hypofunctional allele is increased in both symptomatic and asymptomatic WNV seroconverters (Caucasians from five US centers; total n = 501; OR = 1.6 [95% CI 1.2–2.0], P = 0.0002 in a recessive genetic model). We then directly tested the effect of this SNP on viral replication in a novel ex vivo model of WNV infection in primary human lymphoid tissue. Virus accumulation varied markedly among donors, and was highest for individuals homozygous for the ‘A’ allele (P<0.0001). Together, these data identify OAS1 SNP rs10774671 as a host genetic risk factor for initial infection with WNV in humans

    Cord Blood Sample Screening for Evidence of Maternal Chagas Disease

    No full text

    Cord Blood Sample Screening for Evidence of Maternal Chagas Disease

    No full text

    Seroconverting blood donors as a resource for characterising and optimising recent infection testing algorithms for incidence estimation

    Get PDF
    CITATION: Kassanjee, R. et al. 2011. Seroconverting blood donors as a resource for characterising and optimising recent infection testing algorithms for incidence estimation. PLoS ONE, 6(6): e20027, doi:10.1371/journal.pone.0020027.The original publication is available at http://journals.plos.org/plosoneIntroduction: Biomarker-based cross-sectional incidence estimation requires a Recent Infection Testing Algorithm (RITA) with an adequately large mean recency duration, to achieve reasonable survey counts, and a low false-recent rate, to minimise exposure to further bias and imprecision. Estimating these characteristics requires specimens from individuals with well-known seroconversion dates or confirmed long-standing infection. Specimens with well-known seroconversion dates are typically rare and precious, presenting a bottleneck in the development of RITAs. Methods: The mean recency duration and a 'false-recent rate' are estimated from data on seroconverting blood donors. Within an idealised model for the dynamics of false-recent results, blood donor specimens were used to characterise RITAs by a new method that maximises the likelihood of cohort-level recency classifications, rather than modelling individual sojourn times in recency. Results: For a range of assumptions about the false-recent results (0% to 20% of biomarker response curves failing to reach the threshold distinguishing test-recent and test-non-recent infection), the mean recency duration of the Vironostika-LS ranged from 154 (95% CI: 96-231) to 274 (95% CI: 234-313) days in the South African donor population (n = 282), and from 145 (95% CI: 67-226) to 252 (95% CI: 194-308) days in the American donor population (n = 106). The significance of gender and clade on performance was rejected (p-value = 10%), and utility in incidence estimation appeared comparable to that of a BED-like RITA. Assessment of the Vitros-LS (n = 108) suggested potentially high false-recent rates. Discussion: The new method facilitates RITA characterisation using widely available specimens that were previously overlooked, at the cost of possible artefacts. While accuracy and precision are insufficient to provide estimates suitable for incidence surveillance, a low-cost approach for preliminary assessments of new RITAs has been demonstrated. The Vironostika-LS and Vitros-LS warrant further analysis to provide greater precision of estimates. © 2011 Kassanjee et al.Publisher's versio

    West Nile virus blood transfusion-related infection despite nucleic acid testing

    Get PDF
    BACKGROUND: A case of West Nile virus (WNV) encephalitis associated with transfusion of blood that did not react when tested for WNV by minipool (MP) nucleic acid testing (NAT) is described. A Nebraska man developed clinical encephalitis 13 days after surgery and transfusion of 26 blood components. Antibody testing confirmed WNV infection. An investigation was initiated to determine the source of this infection. STUDY DESIGN AND METHODS: The patient’s family members were interviewed to identify risk factors for WNV infection. Residual samples were retested for WNV RNA using transcription-mediated amplification (TMA) assay and two polymerase chain reaction (PCR) assays. Blood donors’ follow-up serum samples were collected. All samples were tested for WNV-specific immunoglobulin M antibodies. RESULTS: The patient’s family denied recent mosquito exposure. The 20 blood components collected after July 2003 did not react when tested for WNV in a six-member MP-NAT at the time of donation. Retrospective individual testing identified one sample as WNV-reactive by the TMA assay and one of the PCR assays. Seroconversion was demonstrated in the donor associated with this sample. CONCLUSION: WNV RNA detection by individual donation NAT demonstrates viremic blood escaping MPNAT and supports transfusion-related WNV transmission. MP-NAT may not detect all WNV-infected blood donors, allowing WNV transmission to continue at low levels. WNV NAT assays might vary in sensitivity and pooling donations could further impact test performance. Understanding MP NAT limitations can improve strategies to maintain safety of the blood supply in the United States

    Trajectory and Demographic Correlates of Antibodies to SARS-CoV-2 Nucleocapsid in Recently Infected Blood Donors, United States

    No full text
    We evaluated antibodies to the nucleocapsid protein of SARS-CoV-2 in a large cohort of blood donors in the United States who were recently infected with the virus. Antibodies to the nucleocapsid protein of SARS-CoV-2 indicate previous infection but are subject to waning, potentially affecting epidemiologic studies. We longitudinally evaluated a cohort of 19,323 blood donors who had evidence of recent infection by using a widely available serologic test to determine the dynamics of such waning. We analyzed overall signal-to-cutoff values for 48,330 donations (average 2.5 donations/person) that had an average observation period of 102 days. The observed peak signal-to-cutoff value varied widely, but the waning rate was consistent across the range, with a half-life of 122 days. Within the cohort, only 0.75% of persons became seronegative. Factors predictive of higher peak values and longer time to seroreversion included increasing age, male sex, higher body mass index, and non-Caucasian race
    corecore