2,092 research outputs found

    Biomechanical analysis of walking gait when simulating the use of an Ilizarov external fixator

    Get PDF
    The Ilizarov frame is an external fixation device, primarily used for the treatment of complex fractures. The authors postulate that the size and weight of the frame may lead to biomechanical adaptations to gait, independent to any injury. Temporospatial characteristics, kinetics and kinematics were assessed when simulating the use of an Ilizarov frame. Fifteen healthy participants performed walking trials, with and without the simulated frame. Significant changes to temporospatial characteristics were identified, with a decreased mean walking speed (with: 1.24 m s⁻¹; without: 1.29 m s⁻¹) and increased mean step width (with: 0.14 m; without: 0.11 m). The push-off phase of gait differed significantly between test conditions with mean increases in ankle dorsiflexion angles (with: 90.4°; without: 89.0°) and extension moments (proportional to body weight or P BWT) at the knee and ankle (knee with: 0.8 P BWT·m; without: 0.7 P BWT·m; ankle with: 1.6 P BWT·m; without: 1.6 P BWT·m). Although changes were small and likely to be clinically insignificant, the size and weight of the frame led to adaptations which may be magnified for patient groups with associated injury and pain at the lower limb. Results provide an argument for the potential redesign of the frame

    fMRI evidence for a cortical hierarchy of pitch pattern processing

    Get PDF
    Pitch patterns, such as melodies, consist of two levels of structure: a global level, comprising the pattern of ups and downs, or contour; and a local level, comprising the precise intervals that make up this contour. An influential neuropsychological model suggests that these two levels of processing are hierarchically linked, with processing of the global structure occurring within the right hemisphere in advance of local processing within the left. However, the predictions of this model and its anatomical basis have not been tested in neurologically normal individuals. The present study used fMRI and required participants to listen to consecutive pitch sequences while performing a same/different one-back task. Sequences, when different, either preserved (local) or violated (global) the contour of the sequence preceding them. When the activations for the local and global conditions were contrasted directly, additional activation was seen for local processing in right planum temporale and posterior superior temporal sulcus (pSTS). The presence of additional activation for local over global processing supports the hierarchical view that the global structure of a pitch sequence acts as a “framework” on which the local detail is subsequently hung. However, the lateralisation of activation seen in the present study, with global processing occurring in left pSTS and local processing occurring bilaterally, differed from that predicted by the neuroanatomical model. A re-examination of the individual lesion data on which the neuroanatomical model is based revealed that the lesion data equally well support the laterality scheme suggested by our data. While the present study supports the hierarchical view of local and global processing, there is an evident need for further research, both in patients and neurologically normal individuals, before an understanding of the functional lateralisation of local and global processing can be considered established

    Long-term results of a total knee prosthesis utilising an all polyethylene tibial component

    Get PDF
    Introduction The aim of this study was to assess the long-term performance of a cemented total knee replacement utilising an All Polyethylene Tibial (APT) component and in addition to perform an engineering analysis of any failures to help refine surgical technique. Materials and methods A total of 26 patients had a total knee replacement performed using a cemented Depuy Press Fit Condylar (PFC) APT component and a cruciate retaining femoral component. At final review all patients were assessed using The Knee Society Score together with radiographs. An engineering analysis simulated loading conditions of the implants that failed and these were compared with the performance of a modular metal-backed Tibial (MBT) component. Results A total of 20 patients were reviewed at mean time of 116 months following surgery. Knee Society Knee Scores and Function Scores in this cohort were 84/100 and 58/100, respectively. Two patients required revision for tibial component failure. Pre-operatively both had valgus deformities and in each case the tibial tray had been lateralised leaving a gap on the medial side where the APT component had no rigid support. The engineering analysis demonstrated that the volume of highly strained cancellous bone was greater in the APT design compared with the MBT design when a model with a 3 mm medial gap was loaded. The stiffer MBT base plate acted more rigidly and shielded the stress applied to the proximal tibial cancellous bone. Conclusion The APT component demonstrated satisfactory clinical and radiographic performance at long-term follow up. Appropriate cortical support of the APT component is important. The implant should be used with a degree of caution in patients with severe deformities and osteoporosis

    Can the radiopaque marker in surgical swabs scratch orthopaedic implant surfaces?

    Get PDF
    Aims: To determine whether the radiopaque marker strip, which is woven in surgical swabs, causes measureable wear on metal implants at pressures typically used to wipe off fluid from their surface. Materials and methods: Finger pressure used to wipe a surface was measured and used as a reference pressure for further testing. A tribological wear rig was then used to analyse the wear caused on polished titanium plates by a cobalt chromium pin (the control test), the pin covered by a surgical swab and the pin covered by a radiopaque marker strip. Results: It was found that the cotton part or the radiopaque marker of surgical swabs on polished medical grade titanium plates caused no significant wear. In contrast severe scratching was observed from the cobalt chromium pin on its own. Conclusion: To our knowledge, this is the first study in the literature analysing the wear caused by the surgical swabs and radiopaque strip on metal implants. The results suggest that surgical swabs are safe to use on metallic implants at pressures typical of a wiping motion

    Effect of Different Prosthetic Knees/feet on the Roll-Over Shape

    Get PDF
    Roll-over shape (ROS) of knee-ankle-foot (KAF) is a scientific method which has been used to compare performance and design of the different prosthetic foot. In the current study, however, we aimed to understand the influence of the prosthetic components (i.e. knee and foot) on the knee-ankle-foot roll-over shape in a unilateral transfemoral amputee. We performed a case study based on series of experiments with repeated measures on single amputee wearing two different commercially available microprocessor prosthetic knees, during two weeks adaptation period to understand the influence of the prosthetic knee/foot using KAF ROS as an objective measure during level ground walking. The kinematics of the center of pressure (COP), lateral knee and ankle markers were collected and processed to obtain ROS and the results were used to fit a circular shape arc to obtain radius of curvature (ROC). The results indicated that the prosthetic knees have influenced ROC outcomes. The analysis of variance (ANOVA) and post hoc test of the normalized radius of curvature showed the mean of ROC were significantly different between Rheo3 knee, Orion2 and Orion2 with Echelon foot. The amputee reflected his comfort with Rheo3 plus College park foot and Orion with Echelon foot. A conclusion is drawn that multiple comfort zones may exists based on amputee’s ROS metrics. This finding suggests that the design of prosthetic knee should not be considered as a single component but rather as part of a whole system with different comfort zones

    A comparison of course-related stressors in undergraduate problem-based learning (PBL) versus non-PBL medical programmes

    Get PDF
    Background: Medical students report high levels of stress related to their medical training as well as to other personal and financial factors. The aim of this study is to investigate whether there are differences in course-related stressors reported by medical students on undergraduate problem-based learning (PBL) and non-PBL programmes in the UK. Method: A cross-sectional study of second-year medical students in two UK medical schools (one PBL and one non-PBL programme) was conducted. A 16-question self-report questionnaire, derived from the Perceived Medical Student Stress Scale and the Higher Education Stress Inventory, was used to measure course-related stressors. Following univariate analysis of each stressor between groups, multivariate logistic regression was used to determine which stressors were the best predictors of each course type, while controlling for socio-demographic differences between the groups. Results: A total of 280 students responded. Compared to the non-PBL students (N = 197), the PBL students (N = 83) were significantly more likely to agree that: they did not know what the faculty expected of them (Odds Ratio (OR) = 0.38, p = 0.03); there were too many small group sessions facilitated only by students resulting in an unclear curriculum (OR = 0.04, p < 0.0001); and that there was a lack of opportunity to explore academic subjects of interest (OR = 0.40, p = 0.02). They were significantly more likely to disagree that: there was a lack of encouragement from teachers (OR = 3.11, p = 0.02); and that the medical course fostered a sense of anonymity and feelings of isolation amongst students (OR = 3.42, p = 0.008). Conclusion: There are significant differences in the perceived course-related stressors affecting medical students on PBL and non-PBL programmes. Course designers and student support services should therefore tailor their work to minimise, or help students cope with, the specific stressors on each course type to ensure optimum learning and wellbeing among our future doctors

    An investigation of movement dynamics and muscle activity during traditional and accentuated-eccentric squatting.

    Get PDF
    Introduction: Accentuated-eccentric loading (AEL) takes advantage of the high force producing potential of eccentric muscle contractions, potentially maximising mechanical tension within the muscle. However, evidence is lacking on how AEL squatting may load the involved musculature, limiting scientifically justified programming recommendations. The purpose of this study was to investigate the effects of concentric and eccentric loads on joint loading and muscle activity of the lower limbs. Methods: Resistance trained males performed traditional squatting (20–100% of concentric one-repetition maximum [1RM]) and AEL squatting with eccentric loads (110–150% of 1RM) provided by a novel motorised isotonic resistance machine (Kineo). Kinetics and kinematics of the hip, knee, and ankle joints were collected, with electromyography from the gluteus maximus, vastus lateralis, biceps femoris, and gastrocnemius medialis. A secondary cohort underwent a kinematic and electromyography analysis of squatting technique to compare Kineo and back and front barbell squatting. Results: Knee joint peak eccentric moments occurred at 120% 1RM (P = 0.045), with no further increase thereafter. As eccentric load increased, the time course of moment development occurred earlier in the eccentric phase. This resulted in a 37% increase in eccentric knee extensor work from the 80% 1RM trial to the 120% 1RM trial (P<0.001). Neither hip nor ankle joints displayed further change in kinetics as eccentric load increased above 100% 1RM. Electromyographic activity during traditional squatting was ~15–30% lower in all eccentric trials than in concentric trials for all muscles. EMG plateaued between a load of 80–100% 1RM during the eccentric trials and did not increase with AEL. No significant differences in kinematics were found between Kineo and barbell squatting. Conclusions: The knee extensors appear to be preferentially loaded during AEL squatting. The greater work performed during the eccentric phase of the squat as eccentric load increased suggests greater total mechanical tension could be the cause of adaptations from AEL. Our data suggest that AEL should be programmed with a load of 120% of 1RM. Further studies are needed to confirm the longer-term training effects of AEL

    Clarifying Values: An updated review

    Get PDF
    Background: Consensus guidelines have recommended that decision aids include a process for helping patients clarify their values. We sought to examine the theoretical and empirical evidence related to the use of values clarification methods in patient decision aids. Methods: Building on the International Patient Decision Aid Standards (IPDAS) Collaboration's 2005 review of values clarification methods in decision aids, we convened a multi-disciplinary expert group to examine key definitions, decision-making process theories, and empirical evidence about the effects of values clarification methods in decision aids. To summarize the current state of theory and evidence about the role of values clarification methods in decision aids, we undertook a process of evidence review and summary. Results: Values clarification methods (VCMs) are best defined as methods to help patients think about the desirability of options or attributes of options within a specific decision context, in order to identify which option he/she prefers. Several decision making process theories were identified that can inform the design of values clarification methods, but no single "best" practice for how such methods should be constructed was determined. Our evidence review found that existing VCMs were used for a variety of different decisions, rarely referenced underlying theory for their design, but generally were well described in regard to their development process. Listing the pros and cons of a decision was the most common method used. The 13 trials that compared decision support with or without VCMs reached mixed results: some found that VCMs improved some decision-making processes, while others found no effect. Conclusions: Values clarification methods may improve decision-making processes and potentially more distal outcomes. However, the small number of evaluations of VCMs and, where evaluations exist, the heterogeneity in outcome measures makes it difficult to determine their overall effectiveness or the specific characteristics that increase effectiveness

    Cellular Radiosensitivity: How much better do we understand it?

    Get PDF
    Purpose: Ionizing radiation exposure gives rise to a variety of lesions in DNA that result in genetic instability and potentially tumorigenesis or cell death. Radiation extends its effects on DNA by direct interaction or by radiolysis of H2O that generates free radicals or aqueous electrons capable of interacting with and causing indirect damage to DNA. While the various lesions arising in DNA after radiation exposure can contribute to the mutagenising effects of this agent, the potentially most damaging lesion is the DNA double strand break (DSB) that contributes to genome instability and/or cell death. Thus in many cases failure to recognise and/or repair this lesion determines the radiosensitivity status of the cell. DNA repair mechanisms including homologous recombination (HR) and non-homologous end-joining (NHEJ) have evolved to protect cells against DNA DSB. Mutations in proteins that constitute these repair pathways are characterised by radiosensitivity and genome instability. Defects in a number of these proteins also give rise to genetic disorders that feature not only genetic instability but also immunodeficiency, cancer predisposition, neurodegeneration and other pathologies. Conclusions: In the past fifty years our understanding of the cellular response to radiation damage has advanced enormously with insight being gained from a wide range of approaches extending from more basic early studies to the sophisticated approaches used today. In this review we discuss our current understanding of the impact of radiation on the cell and the organism gained from the array of past and present studies and attempt to provide an explanation for what it is that determines the response to radiation
    corecore