8,224 research outputs found

    Validity of a noninvasive estimation of deep body temperature when wearing personal protective equipment during exercise and recovery

    Get PDF
    ©2019 The Authors. Published by BMC. This is an open access article available under a Creative Commons licence. The published version can be accessed at the following link on the publisher’s website: https://doi.org/10.1186/s40779-019-0208-7© 2019 The Author(s). Background: Deep body temperature is a critical indicator of heat strain. However, direct measures are often invasive, costly, and difficult to implement in the field. This study assessed the agreement between deep body temperature estimated from heart rate and that measured directly during repeated work bouts while wearing explosive ordnance disposal (EOD) protective clothing and during recovery. Methods: Eight males completed three work and recovery periods across two separate days. Work consisted of treadmill walking on a 1% incline at 2.5, 4.0, or 5.5 km/h, in a random order, wearing EOD protective clothing. Ambient temperature and relative humidity were maintained at 24 °C and 50% [Wet bulb globe temperature (WBGT) (20.9 ± 1.2) °C] or 32 °C and 60% [WBGT (29.0 ± 0.2) °C] on the separate days, respectively. Heart rate and gastrointestinal temperature (TGI) were monitored continuously, and deep body temperature was also estimated from heart rate (ECTemp). Results: The overall systematic bias between TGI and ECTemp was 0.01 °C with 95% limits of agreement (LoA) of ±0.64 °C and a root mean square error of 0.32 °C. The average error statistics among participants showed no significant differences in error between the exercise and recovery periods or the environmental conditions. At TGI levels of (37.0-37.5) °C, (37.5-38.0) °C, (38.0-38.5) °C, and > 38.5 °C, the systematic bias and ± 95% LoA were (0.08 ± 0.58) °C, (-0.02 ± 0.69) °C, (-0.07 ± 0.63) °C, and (-0.32 ± 0.56) °C, respectively. Conclusions: The findings demonstrate acceptable validity of the ECTemp up to 38.5 °C. Conducting work within an ECTemp limit of 38.4 °C, in conditions similar to the present study, would protect the majority of personnel from an excessive elevation in deep body temperature (> 39.0 °C).This project was financially supported by the Australian Government, managed by the National Security Science & Technology Centre within the Defence Science & Technology Organisation, and the US Government through the Technical Support Working Group within the Combating Terrorism Technical Support Office.Published versio

    Genetic and morphological variation of the lanternfish Lampanyctodes hectoris (Myctophiformes: Myctophidae) off southern Africa

    Get PDF
    Genetic and morphological variation within the southern African population of Lampanyctodes hectoris was analysed. A total of 15 enzymes, encoding 22 isozyme loci, was examined (n = 327); seven were polymorphic. The percentage of polymorphic loci ranged from 13.6 to 27.3%. The mean heterozygosity was generally low and ranged from 0.003 to 0.005. Genetic divergences between specimens from four areas along the west coast of southern Africa were negligible, genetic distance values (D) ranging from 0 to 0.00011. The results showed the population of L. hectoris to be genetically invariant. Principal Component Analysis was performed separately on ratios of 13 morphometric and 6 meristic variables (n = 446), and there was evidence of extensive overlap between fish from all areas. However, discriminant analysis suggested some morphological variability within this population. Although genetically the population of L. hectoris seems to be homogenous, morphologically it appears to be variable. A combination of these results suggests that there is no clear genetic basis for the slight morphological differentiation within the population. Keywords: Agulhas Bank, Benguela Current, lanternfish, Namibia, population geneticsAfrican Journal of Marine Science 2002, 24: 193–20

    TRIM63 (MuRF-1) Gene Polymorphism is Associated with Biomarkers of Exercise-Induced Muscle Damage

    Get PDF
    Unaccustomed strenuous exercise can lead to muscle strength loss, inflammation and delayed onset muscle soreness, which may be influenced by genetic variation. We investigated if a missense single nucleotide polymorphism (A>G, rs2275950) within the TRIM63 gene (encoding MuRF-1 and potentially affecting titin mechanical properties) was associated with the variable response to unaccustomed eccentric exercise. Sixty-five untrained, healthy participants (genotyped for rs2275950: AA, AG and GG) performed 120 maximal eccentric knee extensions (ECC) to induce muscle damage. Isometric and isokinetic maximal voluntary knee extension contractions (MVCs) and muscle soreness were assessed before, immediately after, and 48h after ECC. AA homozygotes were consistently stronger [baseline isometric MVC: 3.23±0.92 Nm/kg (AA) vs. 2.09±0.67 Nm/kg (GG); p=0.006] and demonstrated less muscle soreness over time (p=0.022) compared to GG homozygotes. This may be explained by greater titin stiffness in AA homozygotes, leading to intrinsically stronger muscle fibers that are more resistant to eccentric damaging contractions

    Application of the PM6 method to modeling the solid state

    Get PDF
    The applicability of the recently developed PM6 method for modeling various properties of a wide range of organic and inorganic crystalline solids has been investigated. Although the geometries of most systems examined were reproduced with good accuracy, severe errors were found in the predicted structures of a small number of solids. The origin of these errors was investigated, and a strategy for improving the method proposed

    From social interactions to private environmental behaviours: The case of consumer food waste

    Get PDF
    Consumer food waste, like many environmental behaviours, takes place in private, and is not directly subject to social monitoring. Nevertheless, social interactions can affect private opinions and behaviours. This paper builds an agent-based model of interactions between consumers heterogeneous in their sociability, their initial opinions and behaviours related to food waste, and their willingness to consider different opinions, in order to assess how social interactions can affect private behaviours. Compared to existing models of opinion dynamics, we innovate by including a range of “cognitive dissonance” between stated opinions and actual behaviours that consumers are willing to accept before changing one of the two. We calibrate the model using questionnaire data on household food waste in Italy. We find that a limited degree of mixing between different socio-demographic groups, namely adult and young consumers, is enough to trigger change, but a certain openness of mind is required from more wasteful individuals. Equally, a small group of environmentally committed consumers can attract a sizeable share of the population towards low-waste behaviours if they show a certain variability of opinions and are willing to compromise with individuals in their close neighbourhood in terms of opinions. These findings can help design effective interventions to promote pro-environmental behaviours, taking advantage of the beneficial network effects while anticipating negative externalities

    Extending work tolerance time in the heat in protective ensembles with pre- and per-cooling methods

    Get PDF
    © 2020 Elsevier Ltd Objectives: Investigate whether a range of cooling methods can extend tolerance time and/or reduce physiological strain in those working in the heat dressed in a Class 2 chemical, biological, radiological, nuclear (CBRN) protective ensemble. Methods: Eight males wore a Class 2 CBRN ensemble and walked for a maximum of 120 min at 35 °C, 50% relative humidity. In a randomised order, participants completed the trial with no cooling and four cooling protocols: 1) ice-based cooling vest (IV), 2) a non-ice-based cooling vest (PCM), 3) ice slushy consumed before work, combined with IV (SLIV) and 4) a portable battery-operated water-perfused suit (WPS). Mean with 95% confidence intervals are presented. Results: Tolerance time was extended in PCM (46 [36, 56] min, P = 0.018), SLIV (56 [46, 67] min, P < 0.001) and WPS (62 [53, 70] min, P < 0.001), compared with control (39 [30, 48] min). Tolerance time was longer in SLIV and WPS compared with both IV (48 [39, 58 min]) and PCM (P ≀ 0.011). After 20 min of work, HR was lower in SLIV (121 [105, 136] beats·min−1), WPS (117 [101, 133] beats·min−1) and IV (130 [116, 143] beats·min−1) compared with control (137 [120, 155] beats·min−1) (all P < 0.001). PCM (133 [116, 151] beats·min−1) did not differ from control. Conclusion: All cooling methods, except PCM, utilised in the present study reduced cardiovascular strain, while SLIV and WPS are most likely to extend tolerance time for those working in the heat dressed in a Class 2 CBRN ensemble.This project is financially supported by the United States Government through the United States Department of Defense (DOD).Accepted versio
    • 

    corecore