648 research outputs found

    Experimental arthritis is dependent on mouse mast cell protease-5

    Full text link
    Β© 2017 by The American Society for Biochemistry and Molecular Biology, Inc. The constitutive heparin+ (HP) mast cells (MCs) in mice express mouseMCprotease (mMCP)-5 and carboxypeptidaseA (mMC-CPA). The amino acid sequence ofmMCP-5is most similar to that of human chymase-1, as are the nucleotide sequences of their genes and transcripts. Using a homologous recombination approach, a C57BL/6 mouse line was created that possessed a disrupted mMCP-5 gene. The resulting mice were fertile and had no obvious developmental abnormality. Lack of mMCP-5 protein did not alter the granulation of the IL-3/IL-9-dependent mMCP-2+ MCs in the jejunal mucosa of Trichinella spiralisinfected mice. In contrast, the constitutive HP+ MCs in the tongues of mMCP-5-null mice were poorly granulated and lacked mMC-CPA protein. Bone marrow-derived MCs were readily developed from the transgenic mice using IL-3. Although these MCs contained high levels of mMC-CPA mRNA, they also lacked the latter exopeptidase. mMCP-5 protein is therefore needed to target translated mMC-CPA to the secretory granule along with HP-containing serglycin proteoglycans. Alternately, mMCP-5 is needed to protect mMC-CPA from autolysis in the cell's granules. Fibronectin was identified as a target of mMCP-5, and the exocytosis ofmMCP-5from theMCs in the mouse's peritoneal cavity resulted in the expression of metalloproteinase protease-9, which has been implicated in arthritis. In support of the latter finding, experimental arthritis was markedly reduced in mMCP-5-null mice relative to wildtype mice in two disease models

    Prioritizing sleep for healthy work schedules

    Get PDF
    Good sleep is advantageous to the quality of life. Sleep-related benefits are particularly helpful for the working class, since poor or inadequate amounts of sleep degrade work productivity and overall health. This review paper explores the essential role of sleep in healthy work schedules and primarily focuses on the timing of sleep in relation to the work period (that is, before, during and after work). Data from laboratory, field and modeling studies indicate that consistent amounts of sleep prior to work are fundamental to improved performance and alertness in the workplace. In addition, planned naps taken during work maintain appropriate levels of waking function for both daytime and night-time work. Clearly, sufficient sleep after work is vital in promoting recovery from fatigue. Recent data also suggest that the time interval between shifts should be adjusted according to the biological timing of sleep. Although sleep is more likely to be replaced by job and other activities in the real life, research shows that it is worthwhile to revise the work schedules in order to optimize sleep before, sometime during and after the work period. Therefore, we suggest establishing work-sleep balance, similar to work-life balance, as a principle for designing and improving work schedules

    Periodic eclipses of the young star PDS 110 discovered with WASP and KELT photometry

    Get PDF
    We report the discovery of eclipses by circumstellar disc material associated with the young star PDS 110 in the Ori OB1a association using the SuperWASP and Kilodegree Extremely Little Telescope surveys. PDS 110 (HD 290380, IRAS 05209-0107) is a rare Fe/Ge-type star, an similar to 10 Myr-old accreting intermediate-mass star showing strong infrared excess (L-IR/L-bol similar or equal to 0.25). Two extremely similar eclipses with a depth of 30 per cent and duration similar to 25 d were observed in 2008 November and 2011 January. We interpret the eclipses as caused by the same structure with an orbital period of 808 +/- 2 d. Shearing over a single orbit rules out diffuse dust clumps as the cause, favouring the hypothesis of a companion at similar to 2 au. The characteristics of the eclipses are consistent with transits by an unseen low-mass (1.8-70M(Jup)) planet or brown dwarf with a circumsecondary disc of diameter similar to 0.3 au. The next eclipse event is predicted to take place in 2017 September and could be monitored by amateur and professional observatories across the world

    Pressure transduction and fluid evacuation during conventional negative pressure wound therapy of the open abdomen and NPWT using a protective disc over the intestines

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Negative pressure wound therapy (NPWT) has gained acceptance among surgeons, for the treatment of open abdomen, since very high closure rates have been reported with this method, compared to other kinds of wound management for the open abdomen. However, the method has occasionally been associated with increased development of fistulae. We have previously shown that NPWT induces ischemia in the underlying small intestines close to the vacuum source, and that a protective disc placed between the intestines and the vacuum source prevents the induction of ischemia. In this study we compare pressure transduction and fluid evacuation of the open abdomen with conventional NPWT and NPWT with a protective disc.</p> <p>Methods</p> <p>Six pigs underwent midline incision and the application of conventional NPWT and NPWT with a protective disc between the intestines and the vacuum source. The pressure transduction was measured centrally beneath the dressing, and at the anterior abdominal wall, before and after the application of topical negative pressures of -50, -70 and -120 mmHg. The drainage of fluid from the abdomen was measured, with and without the protective disc.</p> <p>Results</p> <p>Abdominal drainage was significantly better (p < 0. 001) using NPWT with the protective disc at -120 mmHg (439 Β± 25 ml vs. 239 Β± 31 ml), at -70 mmHg (341 Β± 27 ml vs. 166 Β± 9 ml) and at -50 mmHg (350 Β± 50 ml vs. 151 Β± 21 ml) than with conventional NPWT. The pressure transduction was more even at all pressure levels using NPWT with the protective disc than with conventional NPWT.</p> <p>Conclusions</p> <p>The drainage of the open abdomen was significantly more effective when using NWPT with the protective disc than with conventional NWPT. This is believed to be due to the more even and effective pressure transduction in the open abdomen using a protective disc in combination with NPWT.</p

    Microvascular blood flow response in the intestinal wall and the omentum during negative wound pressure therapy of the open abdomen

    Get PDF
    PURPOSE: Higher closure rates of the open abdomen have been reported with negative pressure wound therapy (NPWT) compared with other wound therapy techniques. However, the method has occasionally been associated with increased development of intestinal fistulae. The present study measures microvascular blood flow in the intestinal wall and the omentum before and during NPWT. METHODS: Six pigs underwent midline incision and application of NPWT to the open abdomen. The microvascular blood flow in the underlying intestinal loop wall and the omentum was recorded before and after the application of NPWT of -50, -70, -100, -120, -150, and -170 mmHg respectively, using laser Doppler velocimetry. RESULTS: A significant decrease in microvascular blood flow was seen in the intestinal wall during application of all negative pressures levels. The blood flow was 2.7 (Β±0.2) Perfusion Units (PU) before and 2.0 (Β±0.2) PU (*p < 0.05) after application of -50 mmHg, and 3.6 (Β±0.6) PU before and 1.5 (Β±0.2) PU (**p < 0.01) after application of -170 mmHg. CONCLUSIONS: In the present study, we show that negative pressures between -50 and -170 mmHg induce a significant decrease in the microvascular blood flow in the intestinal wall. The decrease in blood flow increased with the amount of negative pressure applied. One can only speculate that a longstanding decreased blood flow in the intestinal wall may induce ischemia and secondary necrosis in the intestinal wall, which, theoretically, could promote the development of intestinal fistulae. We believe that NPWT of the open abdomen is a very effective treatment but could probably be improved

    Early chronic kidney disease: diagnosis, management and models of care

    Get PDF
    Chronic kidney disease (CKD) is prevalent in many countries, and the costs associated with the care of patients with end-stage renal disease (ESRD) are estimated to exceed US$1 trillion globally. The clinical and economic rationale for the design of timely and appropriate health system responses to limit the progression of CKD to ESRD is clear. Clinical care might improve if early-stage CKD with risk of progression to ESRD is differentiated from early-stage CKD that is unlikely to advance. The diagnostic tests that are currently used for CKD exhibit key limitations; therefore, additional research is required to increase awareness of the risk factors for CKD progression. Systems modelling can be used to evaluate the impact of different care models on CKD outcomes and costs. The US Indian Health Service has demonstrated that an integrated, system-wide approach can produce notable benefits on cardiovascular and renal health outcomes. Economic and clinical improvements might, therefore, be possible if CKD is reconceptualized as a part of primary care. This Review discusses which early CKD interventions are appropriate, the optimum time to provide clinical care, and the most suitable model of care to adopt

    A novel survival model of cardioplegic arrest and cardiopulmonary bypass in rats: a methodology paper

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Given the growing population of cardiac surgery patients with impaired preoperative cardiac function and rapidly expanding surgical techniques, continued efforts to improve myocardial protection strategies are warranted. Prior research is mostly limited to either large animal models or <it>ex vivo </it>preparations. We developed a new <it>in vivo </it>survival model that combines administration of antegrade cardioplegia with endoaortic crossclamping during cardiopulmonary bypass (CPB) in the rat.</p> <p>Methods</p> <p>Sprague-Dawley rats were cannulated for CPB (n = 10). With ultrasound guidance, a 3.5 mm balloon angioplasty catheter was positioned via the right common carotid artery with its tip proximal to the aortic valve. To initiate cardioplegic arrest, the balloon was inflated and cardioplegia solution injected. After 30 min of cardioplegic arrest, the balloon was deflated, ventilation resumed, and rats were weaned from CPB and recovered. To rule out any evidence of cerebral ischemia due to right carotid artery ligation, animals were neurologically tested on postoperative day 14, and their brains histologically assessed.</p> <p>Results</p> <p>Thirty minutes of cardioplegic arrest was successfully established in all animals. Functional assessment revealed no neurologic deficits, and histology demonstrated no gross neuronal damage.</p> <p>Conclusion</p> <p>This novel small animal CPB model with cardioplegic arrest allows for both the study of myocardial ischemia-reperfusion injury as well as new cardioprotective strategies. Major advantages of this model include its overall feasibility and cost effectiveness. In future experiments long-term echocardiographic outcomes as well as enzymatic, genetic, and histologic characterization of myocardial injury can be assessed. In the field of myocardial protection, rodent models will be an important avenue of research.</p
    • …
    corecore