169 research outputs found

    Mapping the optical absorption of a substrate-transferred crystalline AlGaAs coating at 1.5 ”m

    Get PDF
    The sensitivity of 2nd and 3rd generations of interferometric gravitational wave detectors will be limited by thermal noise of the test-mass mirrors and highly reflective coatings. Recently developed crystalline coatings show a promising thermal noise reduction compared to presently used amorphous coatings. However, stringent requirements apply to the optical properties of the coatings as well. We have mapped the optical absorption of a crystalline AlGaAs coating which is optimized for high reflectivity for a wavelength of 1064nm. The absorption was measured at 1550nm where the coating stack transmits approximately 70% of the laser light. The measured absorption was lower than (30.2 +/- 11.1)ppm which is equivalent to (3.6 +/- 1.3)ppm for a coating stack that is highly reflective at 1530nm. While this is a very promising low absorption result for alternative low--loss coating materials, further work will be necessary to reach the requirements of <1ppm for future gravitational wave detectors. Jessica Steinlechner, Iain W Martin, Angus Bell, Garrett Cole, Jim Hough, Steven Penn, Sheila Rowan, Sebastian Steinlechne

    Ion-beam sputtered amorphous silicon films for cryogenic precision measurement systems

    Get PDF
    Thermal noise resulting from the mechanical loss of multilayer dielectric coatings is expected to impose a limit to the sensitivities of precision measurement systems used in fundamental and applied science. In the case of gravitational wave astronomy, future interferometric gravitational wave detectors are likely to operate at cryogenic temperatures to reduce such thermal noise and ameliorate thermal loading effects, with the desirable thermomechanical properties of silicon making it an attractive mirror substrate choice for this purpose. For use in such a precision instrument, appropriate coatings of low thermal noise are essential. Amorphous silicon (a−Si) deposited by e-beam and other techniques has been shown to have low mechanical loss. However, to date, the levels of mechanical and optical loss for a−Si when deposited by ion-beam sputtering (the technique required to produce amorphous mirrors of the specification for gravitational wave detector mirrors) are unknown. In this paper results from measurements of the mechanical loss of a series of IBS a−Si films are presented which show that reductions are possible in coating thermal noise of a factor of 1.5 at 120 K and 2.1 at 20 K over the current best IBS coatings (alternating stacks of silica and titania-doped tantala), with further reductions feasible under appropriate heat treatments

    Family satisfaction with critical care in the UK: a multicentre cohort study.

    Get PDF
    OBJECTIVE: To assess family satisfaction with intensive care units (ICUs) in the UK using the Family Satisfaction in the Intensive Care Unit 24-item (FS-ICU-24) questionnaire, and to investigate how characteristics of patients and their family members impact on family satisfaction. DESIGN: Prospective cohort study nested within a national clinical audit database. SETTING: Stratified, random sample of 20 adult general ICUs participating in the Intensive Care National Audit & Research Centre Case Mix Programme. PARTICIPANTS: Family members of patients staying at least 24 hours in ICU were recruited between May 2013 and June 2014. INTERVENTIONS: Consenting family members were sent a postal questionnaire 3 weeks after the patient died or was discharged from ICU. Up to four family members were recruited per patient. MAIN OUTCOME MEASURES: Family satisfaction was measured using the FS-ICU-24 questionnaire. MAIN RESULTS: A total of 12 346 family members of 6380 patients were recruited and 7173 (58%) family members of 4615 patients returned a completed questionnaire. Overall and domain-specific family satisfaction scores were high (mean overall family satisfaction 80, satisfaction with care 83, satisfaction with information 76 and satisfaction with decision-making 73 out of 100) but varied significantly across adult general ICUs studied and by whether the patient survived ICU. For family members of ICU survivors, characteristics of both the family member (age, ethnicity, relationship to patient (next-of-kin and/or lived with patient) and visit frequency) and the patient (acute severity of illness and receipt of invasive mechanical ventilation) were significant determinants of family satisfaction, whereas, for family members of ICU non-survivors, only patient characteristics (age, acute severity of illness and duration of stay) were significant. CONCLUSIONS: Overall family satisfaction in UK adult general ICUs was high but varied significantly. Adjustment for differences in family member/patient characteristics is important to avoid falsely identifying ICUs as statistical outliers. TRIAL REGISTRATION NUMBER: ISRCTN47363549

    Evaluation of pragmatic oxygenation measurement as a proxy for Covid-19 severity

    Get PDF
    Choosing optimal outcome measures maximizes statistical power, accelerates discovery and improves reliability in early-phase trials. We devised and evaluated a modification to a pragmatic measure of oxygenation function, the [Formula: see text] ratio. Because of the ceiling effect in oxyhaemoglobin saturation, [Formula: see text] ratio ceases to reflect pulmonary oxygenation function at high [Formula: see text] values. We found that the correlation of [Formula: see text] with the reference standard ([Formula: see text]/[Formula: see text] ratio) improves substantially when excluding [Formula: see text] and refer to this measure as [Formula: see text]. Using observational data from 39,765 hospitalised COVID-19 patients, we demonstrate that [Formula: see text] is predictive of mortality, and compare the sample sizes required for trials using four different outcome measures. We show that a significant difference in outcome could be detected with the smallest sample size using [Formula: see text]. We demonstrate that [Formula: see text] is an effective intermediate outcome measure in COVID-19. It is a non-invasive measurement, representative of disease severity and provides greater statistical power

    Evaluation of pragmatic oxygenation measurement as a proxy for Covid-19 severity

    Get PDF
    Choosing optimal outcome measures maximizes statistical power, accelerates discovery and improves reliability in early-phase trials. We devised and evaluated a modification to a pragmatic measure of oxygenation function, the [Formula: see text] ratio. Because of the ceiling effect in oxyhaemoglobin saturation, [Formula: see text] ratio ceases to reflect pulmonary oxygenation function at high [Formula: see text] values. We found that the correlation of [Formula: see text] with the reference standard ([Formula: see text]/[Formula: see text] ratio) improves substantially when excluding [Formula: see text] and refer to this measure as [Formula: see text]. Using observational data from 39,765 hospitalised COVID-19 patients, we demonstrate that [Formula: see text] is predictive of mortality, and compare the sample sizes required for trials using four different outcome measures. We show that a significant difference in outcome could be detected with the smallest sample size using [Formula: see text]. We demonstrate that [Formula: see text] is an effective intermediate outcome measure in COVID-19. It is a non-invasive measurement, representative of disease severity and provides greater statistical power

    Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    Get PDF
    The first science run of the LIGO and GEO gravitational wave detectors presented the opportunity to test methods of searching for gravitational waves from known pulsars. Here we present new direct upper limits on the strength of waves from the pulsar PSR J1939+2134 using two independent analysis methods, one in the frequency domain using frequentist statistics and one in the time domain using Bayesian inference. Both methods show that the strain amplitude at Earth from this pulsar is less than a few times 10−2210^{-22}.Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 200

    Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers

    Get PDF
    We study frequency dependent (FD) input-output schemes for signal-recycling interferometers, the baseline design of Advanced LIGO and the current configuration of GEO 600. Complementary to a recent proposal by Harms et al. to use FD input squeezing and ordinary homodyne detection, we explore a scheme which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are sub-optimal among all possible input-output schemes, provide a global noise suppression by the power squeeze factor, while being realizable by using detuned Fabry-Perot cavities as input/output filters. At high frequencies, the two schemes are shown to be equivalent, while at low frequencies our scheme gives better performance than that of Harms et al., and is nearly fully optimal. We then study the sensitivity improvement achievable by these schemes in Advanced LIGO era (with 30-m filter cavities and current estimates of filter-mirror losses and thermal noise), for neutron star binary inspirals, and for narrowband GW sources such as low-mass X-ray binaries and known radio pulsars. Optical losses are shown to be a major obstacle for the actual implementation of these techniques in Advanced LIGO. On time scales of third-generation interferometers, like EURO/LIGO-III (~2012), with kilometer-scale filter cavities, a signal-recycling interferometer with the FD readout scheme explored in this paper can have performances comparable to existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi
    • 

    corecore