13 research outputs found

    Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study

    Get PDF
    Abstract: Absolute quantification of radiotracer distribution using SPECT/CT imaging is of great importance for dosimetry aimed at personalized radionuclide precision treatment. However, its accuracy depends on many factors. Using phantom measurements, this multi-vendor and multi-center study evaluates the quantitative accuracy and inter-system variability of various SPECT/CT systems as well as the effect of patient size, processing software and reconstruction algorithms on recovery coefficients (RC). Methods: Five SPECT/CT systems were included: Discovery™ NM/CT 670 Pro (GE Healthcare), Precedence™ 6 (Philips Healthcare), Symbia Intevo™, and Symbia™ T16 (twice) (Siemens Healthineers). Three phantoms were used based on the NEMA IEC body phantom without lung insert simulating body mass indexes (BMI) of 25, 28, and 47 kg/m2. Six spheres (0.5–26.5 mL) and background were filled with 0.1 and 0.01 MBq/mL 99mTc-pertechnetate, respectively. Volumes of interest (VOI) of spheres were obtained by a region growing technique using a 50% threshold of the maximum voxel value corrected for background activity. RC, defined as imaged activity concentration divided by actual activity concentration, were determined for maximum (RCmax) and mean voxel value (RCmean) in the VOI for each sphere diameter. Inter-system variability was expressed as median absolute deviation (MAD) of RC. Acquisition settings were standardized. Images were reconstructed using vendor-specific 3D iterative reconstruction algorithms with institute-specific settings used in clinical practice and processed using a standardized, in-house developed processing tool based on the SimpleITK framework. Additionally, all data were reconstructed with a vendor-neutral reconstruction algorithm (Hybrid Recon™; Hermes Medical Solutions). Results: RC decreased with decreasing sphere diameter for each system. Inter-system variability (MAD) was 16 and 17% for RCmean and RCmax, respectively. Standardized reconstruction decreased this variability to 4 and 5%. High BMI hampers quantification of small lesions (< 10 ml). Conclusion: Absolute SPECT quantification in a multi-center and multi-vendor setting is feasible, especially when reconstruction protocols are standardized, paving the way for a standard for absolute quantitative SPECT

    Variability in lutetium-177 SPECT quantification between different state-of-the-art SPECT/CT systems

    Get PDF
    Background: Quantitative SPECT imaging in targeted radionuclide therapy with lutetium-177 holds great potential for individualized treatment based on dose assessment. The establishment of dose-effect relations requires a standardized method for SPECT quantification. The purpose of this multi-center study is to evaluate quantitative accuracy and inter-system variations of different SPECT/CT systems with corresponding commercially available quantitative reconstruction algorithms. This is an important step towards a vendor-independent standard for quantitative lutetium-177 SPECT. Methods: Four state-of-the-art SPECT/CT systems were included: Discovery™ NM/CT 670Pro (GE Healthcare), Symbia Intevo™, and two Symbia™ T16 (Siemens Healthineers). Quantitative accuracy and inter-system variations were evaluated by repeatedly scanning a cylindrical phantom with 6 spherical inserts (0.5 – 113 ml). A sphere-to-background activity concentration ratio of 10:1 was used. Acquisition settings were standardized: medium energy collimator, body contour trajectory, photon energy window of 208 keV (± 10%), adjacent 20% lower scatter window, 2 × 64 projections, 128 × 128 matrix size, and 40 s projection time. Reconstructions were performed using GE Evolution with Q.Metrix™, Siemens xSPECT Quant™, Siemens Broad Quantification™ or Siemens Flash3D™ algorithms using vendor recommended settings. In addition, projection data were reconstructed using Hermes SUV SPECT™ with standardized reconstruction settings to obtain a vendor-neutral quantitative reconstruction for all systems. Volumes of interest (VOI) for the spheres were obtained by applying a 50% threshold of the sphere maximum voxel value corrected for background activity. For each sphere, the mean and maximum recovery coefficient (RCmean and RCmax) of three repeated measurements was calculated, defined as the imaged activity concentration divided by the actual activity concentration. Inter-system variations were defined as the range of RC over all systems. Re

    Population pharmacokinetic dosimetry model using imaging data to assess variability in pharmacokinetics of 177 Lu-PSMA-617 in prostate cancer patients

    Get PDF
    Studies to evaluate and optimize [177 Lu]Lu-PSMA treatment focus primarily on individual patient data. A population pharmacokinetic (PK) dosimetry model was developed to explore the potential of using imaging data as input for population PK models and to characterize variability in organ and tumor uptake of [177 Lu]Lu-PSMA-617 in patients with low volume metastatic prostate cancer. Simulations were performed to identify the effect of dose adjustments on absorbed doses in salivary glands and tumors. A six-compartment population PK model was developed, consisting of blood, salivary gland, kidneys, liver, tumor, and a lumped compartment representing other tissue (compartment 1-6, respectively), based on data from 10 patients who received [177 Lu]Lu-PSMA-617 (2 cycles, ~ 3 and ~ 6 GBq). Data consisted of radioactivity levels (decay corrected) in blood and tissues (9 blood samples and 5 single photon emission computed tomography/computed tomography scans). Observations in all compartments were adequately captured by individual model predictions. Uptake into salivary glands was saturable with an estimated maximum binding capacity (Bmax ) of 40.4 MBq (relative standard error 12.3%) with interindividual variability (IIV) of 59.3% (percent coefficient of variation [CV%]). IIV on other PK parameters was relatively minor. Tumor volume was included as a structural effect on the tumor uptake rate constant (k15 ), where a two-fold increase in tumor volume resulted in a 1.63-fold increase in k15 . In addition, interoccasion variability on k15 improved the model fit (43.5% [CV%]). Simulations showed a reduced absorbed dose per unit administered activity for salivary glands after increasing radioactivity dosing from 3 to 6 GBq (0.685 Gy/GBq vs. 0.421 Gy/GBq, respectively). All in all, population PK modeling could help to improve future radioligand therapy research

    PSMA-RLT in Patients with Metastatic Hormone-Sensitive Prostate Cancer : A Retrospective Study

    Get PDF
    Background: Prostate-specific membrane antigen (PSMA)-directed radioligand therapy (RLT) is a novel treatment for patients with castration-resistant prostate cancer (CRPC). Given the mode of action, patients in an earlier disease stage, such as hormone-sensitive prostate cancer (HSPC), are also likely to benefit from [177Lu]Lu-PSMA- (177Lu-PSMA) or [225Ac]Ac-PSMA-radioligand treatment (225Ac-PSMA). In this retrospective study, we analyzed the safety and efficacy of PSMARLT in early-stage and hormone-sensitive metastatic prostate cancer patients. Methods: A retrospective study was performed in patients who received 177Lu-PSMA and/or 225Ac-PSMA with early-stage metastatic prostate cancer. The primary outcome parameter evaluated in this study was the progression-free survival (PFS) after PSMA-RLT and toxicity according to the Common Terminology Criteria for Adverse Events. Secondary outcome parameters were prostate-specific antigen (PSA) response and the date of onset of CRPC state. Results: In total, 20 patients were included of which 18 patients received 177Lu-PSMA radioligand and two patients received tandem treatment with both 177Lu-PSMA and 225Ac-PSMA radioligands. Patients received a median of 2 treatment cycles (range 1–6) and a median activity of 6.2 GBq 177Lu-PSMA per cycle (interquartile range (IQR) 5.2–7.4 GBq). PSMA-RLT was overall well-tolerated. The most common grade 1–2 side effects were xerostomia (n = 6) and fatigue (n = 8), which were only temporarily reported. One patient that received 225Ac-PSMA developed grade 3–4 bone marrow toxicity. The median PFS was 12 months (95% confidence interval (CI), 4.09–19.9 months). Seventeen (85%) patients had a ≥50% PSA response following PSMA-RLT. One patient developed CRPC 9 months following PSMA-RLT. Conclusions: In this small cohort study, PSMA-RLT appeared safe and showed encouraging efficacy for (metastasized) early-stage and hormone-sensitive prostate cancer patients. Prospective studies are awaited and should include long-term follow-up

    Tumoral Ki67 and PSMA Expression in Fresh Pre-PSMA-RLT Biopsies and Its Relation With PSMA-PET Imaging and Outcomes of PSMA-RLT in Patients With mCRPC

    Get PDF
    INTRODUCTION: Prostate specific membrane antigen (PSMA) directed radioligand therapy (RLT) is a novel therapy for metastatic castration-resistant prostate cancer (mCRPC) patients. However, it is still poorly understood why approximately 40% of the patients does not respond to PSMA-RLT. The aims of this study were to evaluate the pretreatment PSMA expression on immunohistochemistry (IHC) and PSMA uptake on PET/CT imaging in mCRPC patients who underwent PSMA-RLT. We correlated these parameters and a cell proliferation marker (Ki67) to the therapeutic efficacy of PSMA-RLT. PATIENTS AND METHODS: In this retrospective study, mCRPC patients who underwent PSMA-RLT were analyzed. Patients biopsies were scored for immunohistochemical Ki67 expression, PSMA staining intensity and percentage of cells with PSMA expression. Moreover, the PSMA tracer uptake of the tumor lesion(s) and healthy organs on PET/CT imaging was assessed. The primary outcome was to evaluate the association between histological PSMA protein expression of tumor in pre-PSMA-RLT biopsies and the PSMA uptake on PSMA PET/CT imaging of the biopsied lesion. Secondary outcomes were to assess the relationship between PSMA expression and Ki67 on IHC and the progression free survival (PFS) and overall survival (OS) following PSMA-RLT. RESULTS: In total, 22 mCRPC patients were included in this study. Nineteen (86%) patients showed a high and homogenous PSMA expression of >80% on IHC. Three (14%) patients had low PSMA expression on IHC. Although there was limited PSMA uptake on PET/CT imaging, these 3 patients had lower PSMA uptake on PET/CT imaging compared to the patients with high PSMA expression on IHC. Yet, no correlation was found between PSMA uptake on PET/CT imaging and PSMA expression on IHC (SUVmax: R2 = 0.046 and SUVavg: R2 = 0.036). The 3 patients had a shorter PFS compared to the patients with high PSMA expression on IHC (HR: 4.76, 95% CI: 1.14-19.99; P = .033). Patients with low Ki67 expression had a longer PFS and OS compared to patients with a high Ki67 expression (HR: 0.40, 95% CI: 0.15-1.06; P = .013) CONCLUSION: The PSMA uptake on PSMA-PET/CT generally followed the PSMA expression on IHC. However, heterogeneity may be missed on PSMA-PET/CT. Immunohistochemical PSMA and Ki67 expression in fresh tumor biopsies, may contribute to predict treatment efficacy of PSMA-RLT in mCRPC patients. This needs to be further explored in prospective cohorts

    An international multi-center investigation on the accuracy of radionuclide calibrators in nuclear medicine theragnostics

    Get PDF
    Background: Personalized molecular radiotherapy based on theragnostics requires accurate quantification of the amount of radiopharmaceutical activity administered to patients both in diagnostic and therapeutic applications. This international multi-center study aims to investigate the clinical measurement accuracy of radionuclide calibrators for 7 radionuclides used in theragnostics: 99mTc, 111In, 123I, 124I, 131I, 177Lu, and 90Y. Methods: In total, 32 radionuclide calibrators from 8 hospitals located in the Netherlands, Belgium, and Germany were tested. For each radio

    Population pharmacokinetic dosimetry model using imaging data to assess variability in pharmacokinetics of 177Lu‐PSMA‐617 in prostate cancer patients

    No full text
    Abstract Studies to evaluate and optimize [177Lu]Lu‐PSMA treatment focus primarily on individual patient data. A population pharmacokinetic (PK) dosimetry model was developed to explore the potential of using imaging data as input for population PK models and to characterize variability in organ and tumor uptake of [177Lu]Lu‐PSMA‐617 in patients with low volume metastatic prostate cancer. Simulations were performed to identify the effect of dose adjustments on absorbed doses in salivary glands and tumors. A six‐compartment population PK model was developed, consisting of blood, salivary gland, kidneys, liver, tumor, and a lumped compartment representing other tissue (compartment 1–6, respectively), based on data from 10 patients who received [177Lu]Lu‐PSMA‐617 (2 cycles, ~ 3 and ~ 6 GBq). Data consisted of radioactivity levels (decay corrected) in blood and tissues (9 blood samples and 5 single photon emission computed tomography/computed tomography scans). Observations in all compartments were adequately captured by individual model predictions. Uptake into salivary glands was saturable with an estimated maximum binding capacity (Bmax) of 40.4 MBq (relative standard error 12.3%) with interindividual variability (IIV) of 59.3% (percent coefficient of variation [CV%]). IIV on other PK parameters was relatively minor. Tumor volume was included as a structural effect on the tumor uptake rate constant (k15), where a two‐fold increase in tumor volume resulted in a 1.63‐fold increase in k15. In addition, interoccasion variability on k15 improved the model fit (43.5% [CV%]). Simulations showed a reduced absorbed dose per unit administered activity for salivary glands after increasing radioactivity dosing from 3 to 6 GBq (0.685 Gy/GBq vs. 0.421 Gy/GBq, respectively). All in all, population PK modeling could help to improve future radioligand therapy research

    Fibroblast activation protein-targeted radionuclide therapy: background, opportunities, and challenges of first (pre)clinical studies

    Get PDF
    INTRODUCTION: Fibroblast activation protein (FAP) is highly overexpressed in stromal tissue of various cancers. While FAP has been recognized as a potential diagnostic or therapeutic cancer target for decades, the surge of radiolabeled FAP-targeting molecules has the potential to revolutionize its perspective. It is presently hypothesized that FAP targeted radioligand therapy (TRT) may become a novel treatment for various types of cancer. To date, several preclinical and case series have been reported on FAP TRT using varying compounds and showing effective and tolerant results in advanced cancer patients. Here, we review the current (pre)clinical data on FAP TRT and discuss its perspective towards broader clinical implementation. METHODS: A PubMed search was performed to identify all FAP tracers used for TRT. Both preclinical and clinical studies were included if they reported on dosimetry, treatment response or adverse events. The last search was performed on July 22 2022. In addition, a database search was performed on clinical trial registries (date 15th of July 2022) to search for prospective trials on FAP TRT. RESULTS: In total, 35 papers were identified that were related to FAP TRT. This resulted in the inclusion of the following tracers for review: FAPI-04, FAPI-46, FAP-2286, SA.FAP, ND-bisFAPI, PNT6555, TEFAPI-06/07, FAPI-C12/C16, and FSDD. CONCLUSION: To date, data was reported on more than 100 patients that were treated with different FAP targeted radionuclide therapies such as [177Lu]Lu-FAPI-04, [90Y]Y-FAPI-46, [177Lu]Lu-FAP-2286, [177Lu]Lu-DOTA.SA.FAPI and [177Lu]Lu-DOTAGA.(SA.FAPi)2. In these studies, FAP targeted radionuclide therapy has resulted in objective responses in difficult to treat end stage cancer patients with manageable adverse events. Although no prospective data is yet available, these early data encourages further research

    Intra-therapeutic dosimetry of [Lu-177]Lu-PSMA-617 in low-volume hormone-sensitive metastatic prostate cancer patients and correlation with treatment outcome

    Get PDF
    Introduction While [Lu-177]Lu-PSMA radioligand therapy is currently only applied in end-stage metastatic castrate-resistant prostate cancer (mCRPC) patients, also low-volume hormone-sensitive metastatic prostate cancer (mHSPC) patients can benefit from it. However, there are toxicity concerns related to the sink effect in low-volume disease. This prospective study aims to determine the kinetics of [Lu-177]Lu-PSMA in mHSPC patients, analyzing the doses to organs at risk (salivary glands, kidneys, liver, and bone marrow) and tumor lesions 50% at the end of the study) was calculated and given as Spearman's r and p-values.Results Kinetics of [Lu-177]Lu-PSMA in mHSPC patients are comparable to those in mCRPC patients. Lesion absorbed dose was high (3.25 +/- 3.19 Gy/GBq) compared to organ absorbed dose (salivary glands: 0.39 +/- 0.17 Gy/GBq, kidneys: 0.49 +/- 0.11 Gy/GBq, liver: 0.09 +/- 0.01 Gy/GBq, bone marrow: 0.017 +/- 0.008 Gy/GBq). A statistically significant correlation was found between treatment response and absorbed index lesion dose (p = 0.047).Conclusions We successfully performed small lesion dosimetry and showed that the tumor sink effect in mHSPC patients is of less concern than was expected. Tumor-to-organ ratio of absorbed dose was high and tumor uptake correlates with PSA response. Additional treatment cycles are legitimate in terms of organ toxicity and could lead to better tumor response

    Towards standardization of absolute SPECT/CT quantification:a multi-center and multi-vendor phantom study

    No full text
    Absolute quantification of radiotracer distribution using SPECT/CT imaging is of great importance for dosimetry aimed at personalized radionuclide precision treatment. However, its accuracy depends on many factors. Using phantom measurements, this multi-vendor and multi-center study evaluates the quantitative accuracy and inter-system variability of various SPECT/CT systems as well as the effect of patient size, processing software and reconstruction algorithms on recovery coefficients (RC). Methods Five SPECT/CT systems were included: Discovery (TM) NM/CT 670 Pro (GE Healthcare), Precedence (TM) 6 (Philips Healthcare), Symbia Intevo (TM), and Symbia (TM) T16 (twice) (Siemens Healthineers). Three phantoms were used based on the NEMA IEC body phantom without lung insert simulating body mass indexes (BMI) of 25, 28, and 47 kg/m(2). Six spheres (0.5-26.5 mL) and background were filled with 0.1 and 0.01 MBq/mL Tc-99m-pertechnetate, respectively. Volumes of interest (VOI) of spheres were obtained by a region growing technique using a 50% threshold of the maximum voxel value corrected for background activity. RC, defined as imaged activity concentration divided by actual activity concentration, were determined for maximum (RCmax) and mean voxel value (RCmean) in the VOI for each sphere diameter. Inter-system variability was expressed as median absolute deviation (MAD) of RC. Acquisition settings were standardized. Images were reconstructed using vendor-specific 3D iterative reconstruction algorithms with institute-specific settings used in clinical practice and processed using a standardized, in-house developed processing tool based on the SimpleITK framework. Additionally, all data were reconstructed with a vendor-neutral reconstruction algorithm (Hybrid Recon (TM); Hermes Medical Solutions). Results RC decreased with decreasing sphere diameter for each system. Inter-system variability (MAD) was 16 and 17% for RCmean and RCmax, respectively. Standardized reconstruction decreased this variability to 4 and 5%. High BMI hampers quantification of small lesions (<10 ml). Conclusion Absolute SPECT quantification in a multi-center and multi-vendor setting is feasible, especially when reconstruction protocols are standardized, paving the way for a standard for absolute quantitative SPECT
    corecore