3,741 research outputs found

    A Hybrid Screen-Printed Strip for Enhanced Electroanalysis towards Lead and Cadmium in Multi-Matrices

    Get PDF
    Although heavy metals represent a major treat for ecosystem and human health, reference methods for their monitoring are characterized by time-consuming procedures, skilled personel and sophisticated equipment (e.g. ICP-MS, AAS). The development of portable solutions is required, particularly improving interventions and reducing complexity. To this regards, an electrochemical strip for the determination of lead and cadmium in clinical, environmental and food matrices have been developed. The Bismuth film-based flexible device has been optimized and it has been able to detect cadmium and lead, respectively, down to the detection limit of 1.3 and 2 ppb. The use of Whatman No.1 chromatographic paper has allowed to improve the sensitivity towards the detection of heavy metals, because of the porosity that allowed to pre-concentrate species. This led to an improvement in the sensitivity, with a detection limit of 0.3 and 0.5 ppb, respectively, to cadmium and lead, and offers the possibility to tune the sensitivity according to needs, e.g., improving the number of pre-concentration steps. Subsequently, the application of the electrochemical sensor in drinking water, mussel and blood serum was evaluated, demonstrating how these hybrid polyester-paper electrochemical strips can significantly lower the time and costs for on-site measurements, through analytical methods of simple use. The accuracy has been evaluated by comparison with ICP-MS measurements, giving satisfactory results

    Optical Absorption and Scattering Phenomena in 'Jubileum' Plums in Relation to Their Colour Properties

    Get PDF
    Absorption and scattering of laser light pulse passing through the fruit determine among others, the optical properties of the product. Efforts have been made in the recent past to utilize innovative techniques such as time-resolved reflectance spectroscopy (TRS) to study the quality aspects of different fruit such as nectarines. These optical properties have been well related to firmness, sugars, acids and other quality attributes. TRS measurements were performed on ‘Jubileum’ plums at two different wavelengths: 670 nm and 758 nm. The fruit were harvested in Norway and brought to Italy under protected conditions. After sorting the fruit by size, TRS measurements were made and the fruit were randomized for different examinations of quality aspects. It was observed that the absorption coefficient (”a) increased for both wavelengths as ripening progressed towards the melting stage of the fruit. The ”a values at 670 nm were higher than those at 758 nm. The higher rate in the ”a was distinguishable from the third day onwards as the fruit ripened. Similarly, it was interesting to note that the internal colour measured after destructing the fruit related well with the TRS absorption coefficient (”a), i.e., a decrease in the CIE L* (towards darker region) and b* (towards blue) value along with an increase in a* (towards red) from third day of storag

    The spatio-temporal mapping of epileptic networks: Combination of EEG–fMRI and EEG source imaging

    Get PDF
    Simultaneous EEG–fMRI acquisitions in patients with epilepsy often reveal distributed patterns of Blood Oxygen Level Dependant (BOLD) change correlated with epileptiform discharges. We investigated if electrical source imaging (ESI) performed on the interictal epileptiform discharges (IED) acquired during fMRI acquisition could be used to study the dynamics of the networks identified by the BOLD effect, thereby avoiding the limitations of combining results from separate recordings. Nine selected patients (13 IED types identified) with focal epilepsy underwent EEG–fMRI. Statistical analysis was performed using SPM5 to create BOLD maps. ESI was performed on the IED recorded during fMRI acquisition using a realistic head model (SMAC) and a distributed linear inverse solution (LAURA). ESI could not be performed in one case. In 10/12 remaining studies, ESI at IED onset (ESIo) was anatomically close to one BOLD cluster. Interestingly, ESIo was closest to the positive BOLD cluster with maximal statistical significance in only 4/12 cases and closest to negative BOLD responses in 4/12 cases. Very small BOLD clusters could also have clinical relevance in some cases. ESI at later time frame (ESIp) showed propagation to remote sources co-localised with other BOLD clusters in half of cases. In concordant cases, the distance between maxima of ESI and the closest EEG–fMRI cluster was less than 33 mm, in agreement with previous studies. We conclude that simultaneous ESI and EEG–fMRI analysis may be able to distinguish areas of BOLD response related to initiation of IED from propagation areas. This combination provides new opportunities for investigating epileptic networks

    Assembling photoactive materials from polycyclic aromatic hydrocarbons (PAHs): room temperature phosphorescence and excimer-emission in co-crystals with 1,4-diiodotetrafluorobenzene

    Get PDF
    Co-crystallization between the polycyclic aromatic hydrocarbons anthracene (A) and 9-methylanthracene (MA) with 1,4-diiodotetrafluorobenzene (I2F4) afforded three novel co-crystals, viz. A·(I2F4)2 and an unexpectedly complex system with two distinct compositions, namely MA·I2F4 and (MA)4·I2F4, which can be mechanochemically interconverted by a change in the stoichiometry of the reactive mixtures. Interestingly, all co-crystals are dual-emissive materials and exhibit different mechanisms of emission. A·(I2F4)2 and MA·I2F4 fluoresce from isolated molecules, whereas the luminescence of (MA)4·I2F4 is dominated by excimer emission. In all cases, phosphorescence at RT (RTP) is observed and interpreted as a direct consequence of the interactions between the iodine atoms of the I2F4 co-former and the π-electron density of the anthracene aromatic rings. Furthermore, [4 + 4] photoactivity within (MA)4·I2F4 was also investigated by means of FTIR/NMR spectroscopy and PXRD. The photophysical and photochemical behaviors of all solids are discussed and rationalized based on their structural features

    Two Dimensional Quantum Mechanical Modeling of Nanotransistors

    Full text link
    Quantization in the inversion layer and phase coherent transport are anticipated to have significant impact on device performance in 'ballistic' nanoscale transistors. While the role of some quantum effects have been analyzed qualitatively using simple one dimensional ballistic models, two dimensional (2D) quantum mechanical simulation is important for quantitative results. In this paper, we present a framework for 2D quantum mechanical simulation of a nanotransistor / Metal Oxide Field Effect Transistor (MOSFET). This framework consists of the non equilibrium Green's function equations solved self-consistently with Poisson's equation. Solution of this set of equations is computationally intensive. An efficient algorithm to calculate the quantum mechanical 2D electron density has been developed. The method presented is comprehensive in that treatment includes the three open boundary conditions, where the narrow channel region opens into physically broad source, drain and gate regions. Results are presented for (i) drain current versus drain and gate voltages, (ii) comparison to results from Medici, and (iii) gate tunneling current, using 2D potential profiles. Methods to reduce the gate leakage current are also discussed based on simulation results.Comment: 12 figures. Journal of Applied Physics (to appear

    Automated detection of lung nodules in low-dose computed tomography

    Get PDF
    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (~300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scanComment: 4 pages, 2 figures: Proceedings of the Computer Assisted Radiology and Surgery, 21th International Congress and Exhibition, Berlin, Volume 2, Supplement 1, June 2007, pp 357-35

    Experience of a tertiary referral center in managing bladder cancer in conjunction with neurogenic bladder

    Get PDF
    Study design: Case series. Objectives: The aim of this study was to present our experience with the management of bladder cancer (BCa) in individuals followed for neurogenic bladder (NB). Setting: An Italian tertiary referral center for NB. Methods: We retrospectively collected all pre-operative, intra-operative, and post-operative data of our NB cases with BCa, diagnosed from 2004 to 2019. Results: We included ten cases: eight with acquired spinal cord injury (SCI) and two with myelomeningocele (MMC). Considering individuals with acquired SCI, the median age at BCa diagnosis and time since SCI were 53 and 34 years, respectively. One out of seven cases had positive urine cytology. All cases underwent a radical cystectomy, diagnosing squamous cell carcinoma (SCC) and transitional cell carcinoma in 60 and 40% cases, respectively. Surgical-related complications occurred after 90% procedures. Three out of eight individuals with acquired SCI died 2, 12, and 80 months after the diagnosis. Both individuals with MMC presented no evidence of disease after 24 and 27 months. Conclusions: BCa in individuals with NB proved to be associated with a diagnosis at an advanced stage and a high rate of surgical complications. In this population we advocate annual genitourinary ultrasound exam and urine cytology, and cystoscopy in all cases of macrohematuria. Considering the low accuracy of urine cytology and the difficult-to-interpret inflamed bladder walls at cystoscopy in NB, a patient-tailored follow-up schedule based on specific risk factors (e.g., smoking status, indwelling urinary catheter) is mandatory to diagnose and treat BCa at an early stage

    Comparative life cycle assessment study on environmental impact of oil production from micro-algae and terrestrial oilseed crops

    Get PDF
    In this study the LCA methodology is applied in order to satisfy two goals: i) to evaluate the hot spots in site-specific production chain of biodiesel from terrestrial and micro-algae feedstock; ii) to compare quantitatively, utilizing primary data, the impacts of the first generation in respect to the third generation bio-fuels. Results show that micro-algae are neither competitive yet with traditional oil crops nor with fossil fuel. The use of renewable technologies as photovoltaics and biogas self production might increase the competitiveness of micro-algae oil. Further investigations are however necessary to optimize their production chain and to increase the added value of co-products
    • 