    Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments

    Get PDF

    Laboratory Evaluation of Low-Cost Optical Particle Counters for Environmental and Occupational Exposures

    Get PDF
    Low-cost optical particle counters effectively measure particulate matter (PM) mass concentrations once calibrated. Sensor calibration can be established by deriving a linear regression model by performing side-by-side measurements with a reference instrument. However, calibration differences between environmental and occupational settings have not been demonstrated. This study evaluated four commercially available, low-cost PM sensors (OPC-N3, SPS30, AirBeam2, and PMS A003) in both settings. The mass concentrations of three aerosols (salt, Arizona road dust, and Poly-alpha-olefin-4 oil) were measured and compared with a reference instrument. OPC-N3 and SPS30 were highly correlated (r = 0.99) with the reference instrument for all aerosol types in environmental settings. In occupational settings, SPS30, AirBeam2, and PMS A003 exhibited high correlation (>0.96), but the OPC-N3 correlation varied (r = 0.88–1.00). Response significantly (p < 0.001) varied between environmental and occupational settings for most particle sizes and aerosol types. Biases varied by particle size and aerosol type. SPS30 and OPC-N3 exhibited low bias for environmental settings, but all of the sensors showed a high bias for occupational settings. For intra-instrumental precision, SPS30 exhibited high precision for salt for both settings compared to the other low-cost sensors and aerosol types. These findings suggest that SPS30 and OPC-N3 can provide a reasonable estimate of PM mass concentrations if calibrated differently for environmental and occupational settings using site-specific calibration factors

    GeoAirñ€”A Novel Portable, GPS-Enabled, Low-Cost Air-Pollution Sensor: Design Strategies to Facilitate Citizen Science Research and Geospatial Assessments of Personal Exposure

    Get PDF
    The rapid evolution of air sensor technologies has offered enormous opportunities for community-engaged research by enabling citizens to monitor the air quality at any time and location. However, many low-cost portable sensors do not provide sufficient accuracy or are designed only for technically capable individuals by requiring pairing with smartphone applications or other devices to view/store air quality data and collect location data. This paper describes important design considerations for portable devices to ensure effective citizen engagement and reliable data collection for the geospatial analysis of personal exposure. It proposes a new, standalone, portable air monitor, GeoAir, which integrates a particulate matter (PM) sensor, volatile organic compound (VOC) sensor, humidity and temperature sensor, LTE-M and GPS module, Wi-Fi, long-lasting battery, and display screen. The preliminary laboratory test results demonstrate that the PM sensor shows strong performance when compared to a reference instrument. The VOC sensor presents reasonable accuracy, while further assessments with other types of VOC are needed. The field deployment and geo-visualization of the field data illustrate that GeoAir collects fine-grained, georeferenced air pollution data. GeoAir can be used by all citizens regardless of their technical proficiency and is widely applicable in many fields, including environmental justice and health disparity research

    Sensor Selection to Improve Estimates of Particulate Matter Concentration from a Low-Cost Network

    Get PDF
    Deployment of low-cost sensors in the field is increasingly popular. However, each sensor requires on-site calibration to increase the accuracy of the measurements. We established a laboratory method, the Average Slope Method, to select sensors with similar response so that a single, on-site calibration for one sensor can be used for all other sensors. The laboratory method was performed with aerosolized salt. Based on linear regression, we calculated slopes for 100 particulate matter (PM) sensors, and 50% of the PM sensors fell within ±14% of the average slope. We then compared our Average Slope Method with an Individual Slope Method and concluded that our first method balanced convenience and precision for our application. Laboratory selection was tested in the field, where we deployed 40 PM sensors inside a heavy-manufacturing site at spatially optimal locations and performed a field calibration to calculate a slope for three PM sensors with a reference instrument at one location. The average slope was applied to all PM sensors for mass concentration calculations. The calculated percent differences in the field were similar to the laboratory results. Therefore, we established a method that reduces the time and cost associated with calibration of low-cost sensors in the field

    The High-Rise Resolution Carbon Geography of Peru

    Get PDF
    Vegetation is one of the most spatially and temporally dynamic reservoirs of carbon in the world. The amount of carbon stored in vegetation above ground in woody biomass is particularly variable, and is subject to rapid change via land uses that remove vegetation cover, causing carbon emissions. Reducing carbon emissions from deforestation and forest degradation, as well as from other non-forested ecosystems, is therefore a priority in both national and international strategies to conserve ecosystems and to reduce carbon dioxide build-up in the atmosphere.PerĂș harbors an enormous range of ecological conditions, from hot and humid lowland Amazonian forests to high-altitude Andean ecosystems and desert conditions on the Pacific coast. The diversity of environments in PerĂș greatly challenges efforts to measure, map and monitor carbon stocks throughout the country.We report the first high-resolution geographic study of aboveground carbon stocks throughout the more than 128 million hectares that comprise the country of PerĂș. This report communicates the development of our methodology and an extensive validation of the resulting high-resolution carbon map of PerĂș. It also provides the first quantitative analysis of the basic environmental factors determining the carbon geography of Peruvian ecosystems, political regions, and protected areas

    Assessment of PM2.5 Concentration at University Transit Bus Stops Using Low-Cost Aerosol Monitors by Student Commuters

    No full text
    Particulate matter of 2.5 ”m and smaller (PM2.5) is known to cause many respiratory health problems, such as asthma and heart disease. A primary source of PM2.5 is emissions from cars, trucks, and buses. Emissions from university transit bus systems could create zones of high PM2.5 concentration at their bus stops. This work recruited seven university students who regularly utilized the transit system to use a low-cost personal aerosol monitor (AirBeam) each time they arrived at a campus bus stop. Each participant measured PM2.5 concentrations every time they were at a transit-served bus stop over four weeks. PM2.5 concentration data from the AirBeam were compared with an ADR-1500 high-cost monitor and EPA PM2.5 reference measurements. This methodology allowed for identifying higher-than-average concentration zones at the transit bus stops compared to average measurements for the county. By increasing access to microenvironmental data, this project can contribute to public health efforts of personal protection and prevention by allowing individuals to measure and understand their exposure to PM2.5 at the bus stop. This work can also aid commuters, especially those with pre-existing conditions who use public transportation, in making more informed health decisions and better protecting themselves against new or worsening respiratory conditions