77 research outputs found
Recommended from our members
Environmental Tobacco Smoke Exposure in Relation to Family Characteristics, Stressors and Chemical Co-Exposures in California Girls.
Childhood environmental tobacco smoke (ETS) exposure is a risk factor for adverse health outcomes and may disproportionately burden lower socioeconomic status groups, exacerbating health disparities. We explored associations of demographic factors, stressful life events, and chemical co-exposures, with cotinine levels, among girls in the CYGNET Study. Data were collected from families of girls aged 6-8 years old in Northern California, through clinic exams, questionnaires and biospecimens (n = 421). Linear regression and factor analysis were conducted to explore predictors of urinary cotinine and co-exposure body burdens, respectively. In unadjusted models, geometric mean cotinine concentrations were higher among Black (0.59 ug/g creatinine) than non-Hispanic white (0.27), Asian (0.32), or Hispanic (0.34) participants. Following adjustment, living in a rented home, lower primary caregiver education, and lack of two biologic parents in the home were associated with higher cotinine concentrations. Girls who experienced parental separation or unemployment in the family had higher unadjusted cotinine concentrations. Higher cotinine was also associated with higher polybrominated diphenyl ether and metals concentrations. Our findings have environmental justice implications as Black and socio-economically disadvantaged young girls experienced higher ETS exposure, also associated with higher exposure to other chemicals. Efforts to reduce ETS and co-exposures should account for other disparity-related factors
Uncertainty Compensation in Human Attention: Evidence from Response Times and Fixation Durations
BACKGROUND: Uncertainty and predictability have remained at the center of the study of human attention. Yet, studies have only examined whether response times (RT) or fixations were longer or shorter under levels of stimulus uncertainty. To date, no study has examined patterns of stimuli and responses through a unifying framework of uncertainty. METHODOLOGY/PRINCIPAL FINDINGS: We asked 29 college students to generate repeated responses to a continuous series of visual stimuli presented on a computer monitor. Subjects produced these responses by pressing on a keypad as soon a target was detected (regardless of position) while the durations of their visual fixations were recorded. We manipulated the level of stimulus uncertainty in space and time by changing the number of potential stimulus locations and time intervals between stimulus presentations. To allow the analyses to be conducted using uncertainty as common description of stimulus and response we calculated the entropy of the RT and fixation durations. We tested the hypothesis of uncertainty compensation across space and time by fitting the RT and fixation duration entropy values to a quadratic surface. The quadratic surface accounted for 80% of the variance in the entropy values of both RT and fixation durations. RT entropy increased as a function of spatial and temporal uncertainty of the stimulus, alongside a symmetric, compensatory decrease in the entropy of fixation durations as the level of spatial and temporal uncertainty of the stimuli was increased. CONCLUSIONS/SIGNIFICANCE: Our results demonstrate that greater uncertainty in the stimulus leads to greater uncertainty in the response, and that the effects of spatial and temporal uncertainties are compensatory. We also observed compensatory relationship across the entropies of fixation duration and RT, suggesting that a more predictable visual search strategy leads to more uncertain response patterns and vice versa
Evidence for the different physiological significance of the 6- and 2-minute walk tests in multiple sclerosis
<p>Abstract</p> <p>Background</p> <p>Researchers have recently advocated for the 2-minute walk (2MW) as an alternative for the 6-minute walk (6MW) to assess long distance ambulation in persons with multiple sclerosis (MS). This recommendation has not been based on physiological considerations such as the rate of oxygen consumption (V·O<sub>2</sub>) over the 6MW range.</p> <p>Objective</p> <p>This study examined the pattern of change in V·O<sub>2 </sub>over the range of the 6MW in a large sample of persons with MS who varied as a function of disability status.</p> <p>Method</p> <p>Ninety-five persons with clinically-definite MS underwent a neurological examination for generating an Expanded Disability Status Scale (EDSS) score, and then completion of the 6MW protocol while wearing a portable metabolic unit and an accelerometer.</p> <p>Results</p> <p>There was a time main effect on V·O<sub>2 </sub>during the 6MW (<it>p </it>= .0001) such that V·O<sub>2 </sub>increased significantly every 30 seconds over the first 3 minutes of the 6MW, and then remained stable over the second 3 minutes of the 6MW. This occurred despite no change in cadence across the 6MW (<it>p </it>= .84).</p> <p>Conclusions</p> <p>The pattern of change in V·O<sub>2 </sub>indicates that there are different metabolic systems providing energy for ambulation during the 6MW in MS subjects and steady state aerobic metabolism is reached during the last 3 minutes of the 6MW. By extension, the first 3 minutes would represent a test of mixed aerobic and anaerobic work, whereas the second 3 minutes would represent a test of aerobic work during walking.</p
Instrumented gait analysis: a measure of gait improvement by a wheeled walker in hospitalized geriatric patients
Background
In an increasing aging society, reduced mobility is one of the most important factors limiting activities of daily living and overall quality of life. The ability to walk independently contributes to the mobility, but is increasingly restricted by numerous diseases that impair gait and balance. The aim of this cross-sectional observation study was to examine whether spatio-temporal gait parameters derived from mobile instrumented gait analysis can be used to measure the gait stabilizing effects of a wheeled walker (WW) and whether these gait parameters may serve as surrogate marker in hospitalized patients with multifactorial gait and balance impairment.
Methods
One hundred six patients (ages 68–95) wearing inertial sensor equipped shoes passed an instrumented walkway with and without gait support from a WW. The walkway assessed the risk of falling associated gait parameters velocity, swing time, stride length, stride time- and double support time variability. Inertial sensor-equipped shoes measured heel strike and toe off angles, and foot clearance.
Results
The use of a WW improved the risk of spatio-temporal parameters velocity, swing time, stride length and the sagittal plane associated parameters heel strike and toe off angles in all patients. First-time users (FTUs) showed similar gait parameter improvement patterns as frequent WW users (FUs). However, FUs with higher levels of gait impairment improved more in velocity, stride length and toe off angle compared to the FTUs.
Conclusion
The impact of a WW can be quantified objectively by instrumented gait assessment. Thus, objective gait parameters may serve as surrogate markers for the use of walking aids in patients with gait and balance impairments
Urinary concentrations of PAH and VOC metabolites in marijuana users
Background: Marijuana is seeing increased therapeutic use, and is the world\u27s third most-popular recreational drug following alcohol and tobacco. This widening use poses increased exposure to potentially toxic combustion by-products from marijuana smoke and the potential for public health concerns.
Objectives: To compare urinary metabolites of polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) among self-reported recent marijuana users and nonusers, while accounting for tobacco smoke exposure.
Methods: Measurements of PAH and VOC metabolites in urine samples were combined with questionnaire data collected from participants in the National Health and Nutrition Examination Surveys (NHANES) from 2005 to 2012 in order to categorize participants (≥18 years) into exclusive recent marijuana users and nonusers. Adjusted geometric means (GMs) of urinary concentrations were computed for these groups using multiple regression analyses to adjust for potential confounders.
Results: Adjusted GMs of many individual monohydroxy PAHs (OH-PAHs) were significantly higher in recent marijuana users than in nonusers (p\u3c0.05). Urinary thiocyanate (p\u3c0.001) and urinary concentrations of many VOC metabolites, including metabolites of acrylonitrile (p\u3c0.001) and acrylamide (p\u3c0.001), were significantly higher in recent marijuana users than in nonusers.
Conclusions: We found elevated levels of biomarkers for potentially harmful chemicals among self-identified, recent marijuana users compared with nonusers. These findings suggest that further studies are needed to evaluate the potential health risks to humans from the exposure to these agents when smoking marijuana
Differences in Exposure to Nicotine, Tobacco-Specific Nitrosamines, and Volatile Organic Compounds among Electronic Cigarette Users, Tobacco Smokers, and Dual Users from Three Countries
Country-level differences in nicotine vaping products used and biomarkers of exposure among long-term e-cigarette users and dual users remain understudied. This cross-sectional study was conducted in 2014 in the United States (n = 166), United Kingdom (n = 129), and Poland (n = 161). We compared patterns of tobacco product use and nicotine and toxicant exposure among cigarette-only smokers (n = 127); e-cigarette-only users (n = 124); dual users of tobacco cigarettes and e-cigarettes (n = 95); and non-users (control group, n = 110) across three countries using mixed-effects linear regression. Compared with cigarette smokers, e-cigarette-only users had lower levels of toxicant biomarkers, but higher levels of nicotine biomarkers. Dual users had higher levels of toxicant biomarkers than e-cigarette-only users but similar levels to cigarette-only smokers. E-cigarette users in Poland, who overwhelmingly used refillable tank devices, exhibited greater levels of nicotine, and toxicant biomarkers relative to e-cigarette users in US/UK. Despite smoking fewer cigarettes, dual users from Poland exhibited similar levels of nicotine biomarkers compared with UK dual users, but higher than US dual users. Country-level differences in e-cigarette devices used and smoking behaviors (e.g., intensity) may contribute to differences in biomarker levels among users of the same products residing in different countries
- …