516 research outputs found

    A low power photoemission source for electrons on liquid helium

    Full text link
    Electrons on the surface of liquid helium are a widely studied system that may also provide a promising method to implement a quantum computer. One experimental challenge in these studies is to generate electrons on the helium surface in a reliable manner without heating the cryo-system. An electron source relying on photoemission from a zinc film has been previously described using a high power continuous light source that heated the low temperature system. This work has been reproduced more compactly by using a low power pulsed lamp that avoids any heating. About 5e3 electrons are collected on 1 cm^2 of helium surface for every pulse of light. A time-resolved experiment suggests that electrons are either emitted over or tunnel through the 1eV barrier formed by the thin superfluid helium film on the zinc surface. No evidence of trapping or bubble formation is seen.Comment: 9 pages, 3 figures, submitted to J. Low Temp. Phy

    Lower fractional anisotropy without evidence for neuro-inflammation in patients with early-phase schizophrenia spectrum disorders

    Get PDF
    Various lines of research suggest immune dysregulation as a potential therapeutic target for negative and cognitive symptoms in schizophrenia spectrum disorders (SSD). Immune dysregulation would lead to higher extracellular free-water (EFW) in cerebral white matter (WM), which may partially underlie the frequently reported lower fractional anisotropy (FA) in SSD. We aim to investigate differences in EFW concentrations – a presumed proxy for neuro-inflammation – between early-phase SSD patients (n = 55) and healthy controls (HC; n = 37), and to explore immunological and cognitive correlates. To increase specificity for EFW, we study several complementary magnetic resonance imaging contrasts that are sensitive to EFW. FA, mean diffusivity (MD), magnetization transfer ratio (MTR), myelin water fraction (MWF) and quantitative T1 and T2 were calculated from diffusion-weighted imaging (DWI), magnetization transfer imaging (MTI) and multicomponent driven equilibrium single-pulse observation of T1/T2 (mcDESPOT). For each measure, WM skeletons were constructed with tract-based spatial statistics. Multivariate SSD-HC comparisons with WM skeletons and their average values (i.e. global WM) were not statistically significant. In voxel-wise analyses, FA was significantly lower in SSD in the genu of the corpus callosum and in the left superior longitudinal fasciculus (p < 0.04). Global WM measures did not correlate with immunological markers (i.e. IL1-RA, IL-6, IL-8, IL-10 and CRP) or cognition in HC and SSD after corrections for multiple comparisons. We confirmed lower FA in early-phase SSD patients. However, non–FA measures did not provide additional evidence for immune dysregulation or for higher EFW as the primary mechanism underlying the reported lower FA values in SSD

    Auditory hallucinations, top-down processing and language perception: a general population study

    Get PDF
    Background: Studies investigating the underlying mechanisms of hallucinations in patients with schizophrenia suggest that an imbalance in top-down expectations v. bottom-up processing underlies these errors in perception. This study evaluates this hypothesis by testing if individuals drawn from the general population who have had auditory hallucinations (AH) have more misperceptions in auditory language perception than those who have never hallucinated. Methods: We used an online survey to determine the presence of hallucinations. Participants filled out the Questionnaire for Psychotic Experiences and participated in an auditory verbal recognition task to assess both correct perceptions (hits) and misperceptions (false alarms). A hearing test was performed to screen for hearing problems. Results: A total of 5115 individuals from the general Dutch population participated in this study. Participants who reported AH in the week preceding the test had a higher false alarm rate in their auditory perception compared with those without such (recent) experiences. The more recent the AH were experienced, the more mistakes participants made. While the presence of verbal AH (AVH) was predictive for false alarm rate in auditory language perception, the presence of non-verbal or visual hallucinations were not. Conclusions: The presence of AVH predicted false alarm rate in auditory language perception, whereas the presence of non-verbal auditory or visual hallucinations was not, suggesting that enhanced top-down processing does not transfer across modalities. More false alarms were observed in participants who reported more recent AVHs. This is in line with models of enhanced influence of top-down expectations in persons who hallucinate.publishedVersio

    Author Correction:Functional connectome differences in individuals with hallucinations across the psychosis continuum (Scientific Reports, (2021), 11, 1, (1108), 10.1038/s41598-020-80657-8)

    Get PDF
    The Supplementary Information published with this Article contained an error, where an old version of Figure S5 was used. This error has now been corrected in the Supplementary Information file that accompanies the original Article. The corrected Supplementary Information file is also linked to this correction notices.</p

    Author Correction:Functional connectome differences in individuals with hallucinations across the psychosis continuum (Scientific Reports, (2021), 11, 1, (1108), 10.1038/s41598-020-80657-8)

    Get PDF
    The Supplementary Information published with this Article contained an error, where an old version of Figure S5 was used. This error has now been corrected in the Supplementary Information file that accompanies the original Article. The corrected Supplementary Information file is also linked to this correction notices

    The (LATTICE) QCD Potential and Running Coupling: How to Accurately Interpolate between Multi-Loop QCD and the String Picture

    Full text link
    We present a simple parameterization of a running coupling constant, defined via the static potential, that interpolates between 2-loop QCD in the UV and the string prediction in the IR. Besides the usual \Lam-parameter and the string tension, the coupling depends on one dimensionless parameter, determining how fast the crossover from UV to IR behavior occurs (in principle we know how to take into account any number of loops by adding more parameters). Using a new Ansatz for the LATTICE potential in terms of the continuum coupling, we can fit quenched and unquenched Monte Carlo results for the potential down to ONE lattice spacing, and at the same time extract the running coupling to high precision. We compare our Ansatz with 1-loop results for the lattice potential, and use the coupling from our fits to quantitatively check the accuracy of 2-loop evolution, compare with the Lepage-Mackenzie estimate of the coupling extracted from the plaquette, and determine Sommer's scale r0r_0 much more accurately than previously possible. For pure SU(3) we find that the coupling scales on the percent level for β≥6\beta\geq 6.Comment: 47 pages, incl. 4 figures in LaTeX [Added remarks on correlated vs. uncorrelated fits in sect. 4; corrected misprints; updated references.

    D*-->Dpi and D*-->Dgamma decays: Axial coupling and Magnetic moment of D* meson

    Full text link
    The axial coupling and the magnetic moment of D*-meson or, more specifically, the couplings g(D*Dpi) and g(D*Dgamma), encode the non-perturbative QCD effects describing the decays D*-->Dpi and D*-->Dgamma. We compute these quantities by means of lattice QCD with Nf=2 dynamical quarks, by employing the Wilson ("clover") action. On our finer lattice (a=0.065 fm) we obtain: g(D*Dpi)=20 +/- 2, and g(D0*D0gamma)=[2.0 +/- 0.6]/GeV. This is the first determination of g(D0*D0gamma) on the lattice. We also provide a short phenomenological discussion and the comparison of our result with experiment and with the results quoted in the literature.Comment: 22 pages, 3 figure

    Scale-free static and dynamical correlations in melts of monodisperse and Flory-distributed homopolymers: A review of recent bond-fluctuation model studies

    Full text link
    It has been assumed until very recently that all long-range correlations are screened in three-dimensional melts of linear homopolymers on distances beyond the correlation length ξ\xi characterizing the decay of the density fluctuations. Summarizing simulation results obtained by means of a variant of the bond-fluctuation model with finite monomer excluded volume interactions and topology violating local and global Monte Carlo moves, we show that due to an interplay of the chain connectivity and the incompressibility constraint, both static and dynamical correlations arise on distances r≫ξr \gg \xi. These correlations are scale-free and, surprisingly, do not depend explicitly on the compressibility of the solution. Both monodisperse and (essentially) Flory-distributed equilibrium polymers are considered.Comment: 60 pages, 49 figure
    • …
    corecore