1,155 research outputs found

    A simple high-sensitivity technique for purity analysis of xenon gas

    Full text link
    We report on the development and performance of a high-sensitivity purity-analysis technique for gaseous xenon. The gas is sampled at macroscopic pressure from the system of interest using a UHV leak valve. The xenon present in the sample is removed with a liquid-nitrogen cold trap, and the remaining impurities are observed with a standard vacuum mass-spectroscopy device. Using calibrated samples of xenon gas spiked with known levels of impurities, we find that the minimum detectable levels of N2, O2, and methane are 1 ppb, 160 ppt, and 60 ppt respectively. This represents an improvement of about a factor of 10,000 compared to measurements performed without a coldtrap.Comment: 20 pages, 5 figure

    APPLICATION OF MODIFYING ALLOYING ALLOY CONTAINING NANOSIZED POWDERS OF ACTIVE ELEMENTS IN PRODUCTION OF HIGH-STRENGTH CAST IRON WITH GLOBULAR GRAPHITE

    Get PDF
    Scientific and practical interest is the application of alloying alloy-modifiers for secondary treatment of high-strength cast iron to stabilize the process of spheroidization graphite and achieving higher physical-mechanical properties of castings. The peculiarity of the high-strength cast irons manufacturing technology is their tendency to supercooling during solidification in the mold. This leads to the formation of shrinkage defects and structurally free cementite, especially in thin-walled sections of the finished castings. To minimize these effects in foundry practice during production of ductile iron the secondary inoculation is widely used. In this regard, the question of the choice of the additives with effective impact not only on the graphitization process but also on the formation of the metallic base of ductile iron is relevant. The aim of the present work is to study the peculiarities of structure formation in cast iron with nodular graphite when alloying alloy-modifier based on tin with additions of nanoparticles of titanium carbide, yttrium oxide and graphite nano-pipes is used for secondary treatment. Melting of iron in laboratory conditions was performed in crucible induction furnace IST-006 with an acid lining held. Spheroidizing treatment of melt was realized with magnesium containing alloying alloy FeSiMg7 by means of ladle method. Secondary treatment of high strength cast iron was carried out by addition of alloying alloy-modifier in an amount of 0.1% to the bottom of the pouring ladle. Cast samples for chemical composition analysis, study of microstructure, technological and mechanical properties of the resultant alloy were made. Studies have shown that the secondary treatment of high strength cast iron with developed modifier-alloying alloy results in formation of the perlite metallic base due to the tin impact and nodular graphite with regular shape under the influence of titanium carbide, yttrium oxide and graphite nano-pipes. The tendency of high strength cast iron to «white cast iron» formation has been minimized, and the mechanical properties of the alloy produced correspond to HSCI80

    Study of a zirconium getter for purification of xenon gas

    Full text link
    Oxygen, nitrogen and methane purification efficiencies for a common zirconium getter are measured in 1050 Torr of xenon gas. Starting with impurity concentrations near 10^{-6} g/g, the outlet impurity level is found to be less than 120*10^{-12} g/g for O2 and less than 950*10^{-12} g/g for N2. For methane we find residual contamination of the purified gas at concentrations varying over three orders of magnitude, depending on the purifier temperature and the gas flow rate. A slight reduction in the purifier's methane efficiency is observed after 13 mg of this impurity has been absorbed, which we attribute to partial exhaustion of the purifier's capacity for this species. We also find that the purifier's ability to absorb N2 and methane can be extinguished long before any decrease in O2 performance is observed, and slower flow rates should be employed for xenon purification due to the cooling effect that the heavy gas has on the getter.Comment: 14 pages, 5 figure

    A prototype vector magnetic field monitoring system for a neutron electric dipole moment experiment

    Get PDF
    We present results from a first demonstration of a magnetic field monitoring system for a neutron electric dipole moment experiment. The system is designed to reconstruct the vector components of the magnetic field in the interior measurement region solely from exterior measurements

    A Xenon Condenser with a Remote Liquid Storage Vessel

    Full text link
    We describe the design and operation of a system for xenon liquefaction in which the condenser is separated from the liquid storage vessel. The condenser is cooled by a pulse tube cryocooler, while the vessel is cooled only by the liquid xenon itself. This arrangement facilitates liquid particle detector research by allowing easy access to the upper and lower flanges of the vessel. We find that an external xenon gas pump is useful for increasing the rate at which cooling power is delivered to the vessel, and we present measurements of the power and efficiency of the apparatus.Comment: 22 pages, 7 figures Corrected typos in authors lis

    Interplay between geometry and flow distribution in an airway tree

    Full text link
    Uniform fluid flow distribution in a symmetric volume can be realized through a symmetric branched tree. It is shown here, however, that the flow partitioning can be highly sensitive to deviations from exact symmetry if inertial effects are present. This is found by direct numerical simulation of the Navier-Stokes equations in a 3D tree geometry. The flow asymmetry is quantified and found to depend on the Reynolds number. Moreover, for a given Reynolds number, we show that the flow distribution depends on the aspect ratio of the branching elements as well as their angular arrangement. Our results indicate that physiological variability should be severely restricted in order to ensure uniform fluid distribution in a tree. This study suggests that any non-uniformity in the air flow distribution in human lungs should be influenced by the respiratory conditions, rest or hard exercise

    The Critical Coupling Likelihood Method: A new approach for seamless integration of environmental and operating conditions of gravitational wave detectors into gravitational wave searches

    Get PDF
    Any search effort for gravitational waves (GW) using interferometric detectors like LIGO needs to be able to identify if and when noise is coupling into the detector's output signal. The Critical Coupling Likelihood (CCL) method has been developed to characterize potential noise coupling and in the future aid GW search efforts. By testing two hypotheses about pairs of channels, CCL is able to identify undesirable coupled instrumental noise from potential GW candidates. Our preliminary results show that CCL can associate up to ∌80\sim 80% of observed artifacts with SNR≄8SNR \geq 8, to local noise sources, while reducing the duty cycle of the instrument by â‰Č15\lesssim 15%. An approach like CCL will become increasingly important as GW research moves into the Advanced LIGO era, going from the first GW detection to GW astronomy.Comment: submitted CQ

    GEO 600 and the GEO-HF upgrade program: successes and challenges

    Get PDF
    The German-British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001. After GEO 600 participated in science runs with other first-generation detectors, a program known as GEO-HF began in 2009. The goal was to improve the detector sensitivity at high frequencies, around 1 kHz and above, with technologically advanced yet minimally invasive upgrades. Simultaneously, the detector would record science quality data in between commissioning activities. As of early 2014, all of the planned upgrades have been carried out and sensitivity improvements of up to a factor of four at the high-frequency end of the observation band have been achieved. Besides science data collection, an experimental program is ongoing with the goal to further improve the sensitivity and evaluate future detector technologies. We summarize the results of the GEO-HF program to date and discuss its successes and challenges

    Cost-benefit analysis for commissioning decisions in GEO600

    Get PDF
    Gravitational wave interferometers are complex instruments, requiring years of commissioning to achieve the required sensitivities for the detection of gravitational waves, of order 10^-21 in dimensionless detector strain, in the tens of Hz to several kHz frequency band. Investigations carried out by the GEO600 detector characterisation group have shown that detector characterisation techniques are useful when planning for commissioning work. At the time of writing, GEO600 is the only large scale laser interferometer currently in operation running with a high duty factor, 70%, limited chiefly by the time spent commissioning the detector. The number of observable gravitational wave sources scales as the product of the volume of space to which the detector is sensitive and the observation time, so the goal of commissioning is to improve the detector sensitivity with the least possible detector down time. We demonstrate a method for increasing the number of sources observable by such a detector, by assessing the severity of non-astrophysical noise contaminations to efficiently guide commissioning. This method will be particularly useful in the early stages and during the initial science runs of the aLIGO and adVirgo detectors, as they are brought up to design performance.Comment: 17 pages, 17 figures, 2 table

    Methods for Reducing False Alarms in Searches for Compact Binary Coalescences in LIGO Data

    Get PDF
    The LIGO detectors are sensitive to a variety of noise transients of non-astrophysical origin. Instrumental glitches and environmental disturbances increase the false alarm rate in the searches for gravitational waves. Using times already identified when the interferometers produced data of questionable quality, or when the channels that monitor the interferometer indicated non-stationarity, we have developed techniques to safely and effectively veto false triggers from the compact binary coalescences (CBCs) search pipeline
    • 

    corecore