13,516 research outputs found

    Catching NGC4051 in the low state with XMM-Newton

    Full text link
    The Narrow Line Seyfert 1 galaxy NGC4051 shows unusual low flux states, lasting several months, when the 2-10 keV X-ray spectrum becomes unusually hard (photon index<1) while the spectrum at lower X-ray energies is dominated by a large soft excess. A Chandra TOO of the low state has shown that the soft excess and hard components are variable and well-correlated. The variability of the hard component rules out an origin in a distant reflector. Here we present results from a recent XMM-Newton TOO of NGC4051 in the low state, which allows a much more detailed examination of the nature of the hard and soft spectral components in the low state. We demonstrate that the spectral shape in the low state is consistent with the extrapolation of the spectral pivoting observed at higher fluxes. The XMM-Newton data also reveals the warm absorbing gas in emission, as the drop in the primary continuum flux unmasks prominent emission lines from a range of ion species.Comment: 4 pages, 4 figures. Proc. of the meeting: "The Restless High-Energy Universe" (Amsterdam, The Netherlands), E.P.J. van den Heuvel, J.J.M. in 't Zand, and R.A.M.J. Wijers Ed

    Predicting sustainable arsenic mitigation using machine learning techniques.

    Full text link
    This study evaluates state-of-the-art machine learning models in predicting the most sustainable arsenic mitigation preference. A Gaussian distribution-based Naïve Bayes (NB) classifier scored the highest Area Under the Curve (AUC) of the Receiver Operating Characteristic curve (0.82), followed by Nu Support Vector Classification (0.80), and K-Neighbors (0.79). Ensemble classifiers scored higher than 70% AUC, with Random Forest being the top performer (0.77), and Decision Tree model ranked fourth with an AUC of 0.77. The multilayer perceptron model also achieved high performance (AUC=0.75). Most linear classifiers underperformed, with the Ridge classifier at the top (AUC=0.73) and perceptron at the bottom (AUC=0.57). A Bernoulli distribution-based Naïve Bayes classifier was the poorest model (AUC=0.50). The Gaussian NB was also the most robust ML model with the slightest variation of Kappa score on training (0.58) and test data (0.64). The results suggest that nonlinear or ensemble classifiers could more accurately understand the complex relationships of socio-environmental data and help develop accurate and robust prediction models of sustainable arsenic mitigation. Furthermore, Gaussian NB is the best option when data is scarce

    von Willebrand factor/ADAMTS13 ratio at presentation of acute ischemic brain injury is predictive of outcome

    Get PDF
    Acute ischemic stroke (IS) and transient ischemic attack (TIA) are associated with raised von Willebrand factor (VWF) and decreased ADAMTS13 activity (ADAMTS13Ac). Their impact on mortality and morbidity is unclear. We conducted a prospective investigation of the VWF-ADAMTS13 axis in 292 adults (acute IS, n = 103; TIA, n = 80; controls, n = 109) serially from presentation until >6 weeks. The National Institutes of Health Stroke Score (NIHSS) and modified Rankin scale (mRS) were used to assess stroke severity. Presenting median VWF antigen (VWF:Ag)/ADAMTS13Ac ratios were: IS, 2.42 (range, 0.78-9.53); TIA, 1.89 (range, 0.41-8.14); and controls, 1.69 (range, 0.25-15.63). Longitudinally, the median VWF:Ag/ADAMTS13Ac ratio decreased (IS, 2.42 to 1.66; P = .0008; TIA, 1.89 to 0.65; P 2.6 predicted mortality (odds ratio, 6.33; range, 2.22-18.1). Those with a VWF:Ag/ADAMTS13Ac ratio in the highest quartile (>3.091) had 31% increased risk mortality. VWF:Ag/ADAMTS13Ac ratio at presentation of ischemic brain injury was associated with higher mRS (P = .021) and NIHSS scores (P = .029) at follow-up. Thrombolysis resulted in prompt reduction of the VWF:Ag/ADAMTS13Ac ratio and significant improvement in mRS on follow-up. A raised VWF:Ag/ADAMTS13Ac ratio at presentation of acute IS or TIA is associated with increased mortality and poorer functional outcome. A ratio of 2.6 seems to differentiate outcome. Prompt reduction in the ratio in thrombolysed patients was associated with decreased mortality and morbidity. The VWF:Ag/ADAMTS13Ac ratio is a biomarker for the acute impact of an ischemic event and longer-term outcome

    Behaviour of Magnetic Tubes in Neutron Star's Interior

    Full text link
    It is found from Maxwell's equations that the magnetic field lines are good analogues of relativistic strings. It is shown that the super-conducting current in the neutron star's interior causes local rotation of magnetic flux tubes carrying quantized flux.Comment: 6 pages, no figure

    Trajectory mapping: A tool for validation of trace gas observations

    Get PDF
    We investigate the effectiveness of trajectory mapping(TM) as a data validation tool. TM combines a dynamical model of the atmosphere with trace gas observations to provide more statistically robust estimates of instrument performance over much broader geographic areas than traditional techniques are able to provide. We present four detailed case studies selected so that the traditional techniques are expected to work well. In each case the TM results are equivalent to or improve upon the measurement comparisons performed with traditional approaches. The TM results are statistically more robust than those achieved using traditional approaches since the TM comparisons occur over a much larger range of geophysical variability. In the first case study we compare ozone data from the Halogen Occultation Experiment (HALOE) with Microwave Limb Sounder(MLS). TM comparisons appear to introduce little to no error as compared to the traditional approach. In the second case study we compare ozone data from HALOE with that from the Stratospheric Aerosol and Gas Experiment TT(SAGE TT). TM results in differences of less than 5% as compared to the traditional approach at altitudes between 18 and 25 km and less than 10% at altitudes between 25 and 40 km.In the third case study we show that ozone profiles generated from HALOE data using TM compare well with profiles from five European ozonesondes. In the fourth case study we evaluate the precision of MLS H20 using TM and find typical precision uncertainties of 3-7% at most latitudes and altitudes. The TM results agree well with previous estimates but are the result of a global analysis of the data rather than an analysis in the limited latitude bands in which traditional approaches work. Finally, sensitivity studies using the MLS H20 data show the following: (1) a combination of forward and backward trajectory calculations minimize uncertainties in isentropic TM; (2) although the uncertainty of the technique increases with trajectory duration,TM calculations of up to 14 days can provide reliable information for use in data validation studies; (3) a correlation coincidence criterion of 400 km produces the best TM results under most circumstances; (4) TM performs well compared to (and sometimes better than) traditional approaches at all latitudes and in most seasons and; (5) TM introduces no statistically significant biases at altitudes between 22 and 40 km

    Grand Challenges in Global Health: The Ethical, Social and Cultural Program

    Get PDF
    The Grand Challenges initiative has 44 projects worldwide aimed at addressing diseases of the poor. What are the ethical, social, and cultural issues that the initiative faces
    corecore