23 research outputs found

    Imagined Self-Motion Differs from Perceived Self-Motion: Evidence from a Novel Continuous Pointing Method

    Get PDF
    Background The extent to which actual movements and imagined movements maintain a shared internal representation has been a matter of much scientific debate. Of the studies examining such questions, few have directly compared actual full-body movements to imagined movements through space. Here we used a novel continuous pointing method to a) provide a more detailed characterization of self-motion perception during actual walking and b) compare the pattern of responding during actual walking to that which occurs during imagined walking. Methodology/Principal Findings This continuous pointing method requires participants to view a target and continuously point towards it as they walk, or imagine walking past it along a straight, forward trajectory. By measuring changes in the pointing direction of the arm, we were able to determine participants' perceived/imagined location at each moment during the trajectory and, hence, perceived/imagined self-velocity during the entire movement. The specific pattern of pointing behaviour that was revealed during sighted walking was also observed during blind walking. Specifically, a peak in arm azimuth velocity was observed upon target passage and a strong correlation was observed between arm azimuth velocity and pointing elevation. Importantly, this characteristic pattern of pointing was not consistently observed during imagined self-motion. Conclusions/Significance Overall, the spatial updating processes that occur during actual self-motion were not evidenced during imagined movement. Because of the rich description of self-motion perception afforded by continuous pointing, this method is expected to have significant implications for several research areas, including those related to motor imagery and spatial cognition and to applied fields for which mental practice techniques are common (e.g. rehabilitation and athletics)

    SpikeInterface, a unified framework for spike sorting

    Get PDF
    Much development has been directed toward improving the performance and automation of spike sorting. This continuous development, while essential, has contributed to an over-saturation of new, incompatible tools that hinders rigorous benchmarking and complicates reproducible analysis. To address these limitations, we developed SpikeInterface, a Python framework designed to unify preexisting spike sorting technologies into a single codebase and to facilitate straightforward comparison and adoption of different approaches. With a few lines of code, researchers can reproducibly run, compare, and benchmark most modern spike sorting algorithms; pre-process, post-process, and visualize extracellular datasets; validate, curate, and export sorting outputs; and more. In this paper, we provide an overview of SpikeInterface and, with applications to real and simulated datasets, demonstrate how it can be utilized to reduce the burden of manual curation and to more comprehensively benchmark automated spike sorters.ISSN:2050-084

    Design and Fabrication of Ultralight Weight, Adjustable Multi-electrode Probes for Electrophysiological Recordings in Mice

    Get PDF
    The number of physiological investigations in the mouse, mus musculus, has experienced a recent surge, paralleling the growth in methods of genetic targeting for microcircuit dissection and disease modeling. The introduction of optogenetics, for example, has allowed for bidirectional manipulation of genetically-identified neurons, at an unprecedented temporal resolution. To capitalize on these tools and gain insight into dynamic interactions among brain microcircuits, it is essential that one has the ability to record from ensembles of neurons deep within the brain of this small rodent, in both head-fixed and freely behaving preparations. To record from deep structures and distinct cell layers requires a preparation that allows precise advancement of electrodes towards desired brain regions. To record neural ensembles, it is necessary that each electrode be independently movable, allowing the experimenter to resolve individual cells while leaving neighboring electrodes undisturbed. To do both in a freely behaving mouse requires an electrode drive that is lightweight, resilient, and highly customizable for targeting specific brain structures. A technique for designing and fabricating miniature, ultralight weight, microdrive electrode arrays that are individually customizable and easily assembled from commercially available parts is presented. These devices are easily scalable and can be customized to the structure being targeted; it has been used successfully to record from thalamic and cortical regions in a freely behaving animal during natural behavior.Simons FoundationNational Institute of Neurological Disorders and Stroke (U.S.) (NIH Pathway to Independence Career Award)National Institutes of Health (U.S.

    Neurodata Without Borders: Creating a Common Data Format for Neurophysiology

    Get PDF
    The Neurodata Without Borders (NWB) initiative promotes data standardization in neuroscience to increase research reproducibility and opportunities. In the first NWB pilot project, neurophysiologists and software developers produced a common data format for recordings and metadata of cellular electrophysiology and optical imaging experiments. The format specification, application programming interfaces, and sample datasets have been released

    Causal evidence for the behavioral impact of oscillations in neocortex and hippocampus

    No full text
    Thesis: Ph. D., Massachusetts Institute of Technology, Department of Brain and Cognitive Sciences, 2014.Cataloged from PDF version of thesis.Includes bibliographical references.Neuroscientists hold widely divergent opinions on the behavioral relevance of oscillatory brain states. Some consider them to be a side effect of anatomical connectivity, with little or no role in guiding action. Others view them as a fundamental feature of the network states that underlie perception and cognition. In this thesis, I take a systematic approach to studying two of the most prominent types of oscillations,'gamma rhythms in the neocortex (30-80 Hz) and theta rhythms in the hippocampus (4-12 Hz). In both cases, I use light-gated ion channels to manipulate spike activity on a cycle-by-cycle basis in awake, behaving mice. By rhythmically stimulating fast-spiking interneurons in somatosensory cortex, I can emulate the activity patterns that define gamma oscillations under natural conditions. Emulating gamma enhances the detection of threshold-level vibrissae deflections, analogous to the behavioral effects of shifting attention. By triggering stimulation of fast-spiking interneurons in the hippocampus on peaks and troughs of endogenous rhythms, I can reduce spike activity at specific phases of theta. In the context of a spatial navigation task, I find that the ability of inhibition to enhance decision-making accuracy depends on both the theta phase and the task segment in which it occurs. Both of these experiments provide novel causal evidence for the behavioral impact of oscillations, which offers a much more compelling argument for their utility than traditional correlative measures. Finally, I present a new platform for extracellular electrophysiology. This platform, called Open Ephys, makes the closed-loop experiments that are ideal for studying oscillations accessible to a wider audience.by Joshua H. Siegle.Ph. D

    The flexDrive: an ultra-light implant for optical control and highly parallel chronic recording of neuronal ensembles in freely moving mice

    Get PDF
    Electrophysiological recordings from ensembles of neurons in behaving mice are a central tool in the study of neural circuits. Despite the widespread use of chronic electrophysiology, the precise positioning of recording electrodes required for high-quality recordings remains a challenge, especially in behaving mice. The complexity of available drive mechanisms, combined with restrictions on implant weight tolerated by mice, limits current methods to recordings from no more than 4–8 electrodes in a single target area. We developed a highly miniaturized yet simple drive design that can be used to independently position 16 electrodes with up to 64 channels in a package that weighs ~2 g. This advance over current designs is achieved by a novel spring-based drive mechanism that reduces implant weight and complexity. The device is easy to build and accommodates arbitrary spatial arrangements of electrodes. Multiple optical fibers can be integrated into the recording array and independently manipulated in depth. Thus, our novel design enables precise optogenetic control and highly parallel chronic recordings of identified single neurons throughout neural circuits in mice.Brown University. Brain Science ProgramNational Institutes of Health (U.S.) (Grant 5R01NS045130-09

    Sharing neurophysiology data from the Allen Brain Observatory

    No full text
    Nullius in verba (‘trust no one’), chosen as the motto of the Royal Society in 1660, implies that independently verifiable observations—rather than authoritative claims—are a defining feature of empirical science. As the complexity of modern scientific instrumentation has made exact replications prohibitive, sharing data is now essential for ensuring the trustworthiness of one’s findings. While embraced in spirit by many, in practice open data sharing remains the exception in contemporary systems neuroscience. Here, we take stock of the Allen Brain Observatory, an effort to share data and metadata associated with surveys of neuronal activity in the visual system of laboratory mice. Data from these surveys have been used to produce new discoveries, to validate computational algorithms, and as a benchmark for comparison with other data, resulting in over 100 publications and preprints to date. We distill some of the lessons learned about open surveys and data reuse, including remaining barriers to data sharing and what might be done to address these

    Open Ephys: An open-source, plugin-based platform for multichannel electrophysiology

    No full text
    [Objective] Closed-loop experiments, in which causal interventions are conditioned on the state of the system under investigation, have become increasingly common in neuroscience. Such experiments can have a high degree of explanatory power, but they require a precise implementation that can be difficult to replicate across laboratories. We sought to overcome this limitation by building open-source software that makes it easier to develop and share algorithms for closed-loop control.[Approach] We created the Open Ephys GUI, an open-source platform for multichannel electrophysiology experiments. In addition to the standard 'open-loop' visualization and recording functionality, the GUI also includes modules for delivering feedback in response to events detected in the incoming data stream. Importantly, these modules can be built and shared as plugins, which makes it possible for users to extend the functionality of the GUI through a simple API, without having to understand the inner workings of the entire application.[Main results] In combination with low-cost, open-source hardware for amplifying and digitizing neural signals, the GUI has been used for closed-loop experiments that perturb the hippocampal theta rhythm in a phase-specific manner.[Significance] The Open Ephys GUI is the first widely used application for multichannel electrophysiology that leverages a plugin-based workflow. We hope that it will lower the barrier to entry for electrophysiologists who wish to incorporate real-time feedback into their research.Peer reviewe

    Difference between completing the imagined condition first versus last.

    No full text
    <p>Six of the participants completed the IM condition first, while another six completed it last. Here, the percentage of maximum angular velocity at each degree of arm azimuth is compared for participants who completed the IM condition first (magenta line) to the participants who completed it last (cyan line). Black lines represent SW and blue lines represent BW. A) For the elevated target trials, a significant difference was observed when comparing the IM first versus IM last trials for the 5 m path length but not for the 6 m path length. B) For the floor level targets there was no difference between IM first and IM last for either distance. The shaded areas represent plus and minus one standard error of the mean.</p
    corecore