741 research outputs found

    The adaptation of a 360° camera utilising an alternate light source (ALS) for the detection of biological fluids at crime scenes.

    Get PDF
    One of the most important and commonly encountered evidence types that can be recovered at crime scenes are biological fluids. Due to the ephemeral nature of biological fluids and the valuable DNA that they can contain, it is fundamental that these are documented extensively and recovered rapidly. Locating and identifying biological fluids can prove a challenging task but can aid in reconstructing a sequence of events. Alternate light sources (ALS) offer powerful non-invasive methods for locating and enhancing biological fluids utilising different wavelengths of light. Current methods for locating biological fluids using ALS's may be time consuming, as they often require close range searching of potentially large crime scenes. Subsequent documentation using digital cameras and alternate light sources can increase the investigation time and due to the cameras low dynamic range, photographs can appear under or over exposed. This study presents a technique, which allows the simultaneous detection and visualisation of semen and saliva utilising a SceneCam 360° camera (Spheron VR AG), which was adapted to integrate a blue Crime Lite XL (Foster+Freeman). This technique was investigated using different volumes of semen and saliva, on porous and non-porous substrates, and the ability to detect these at incremental distances from the substrate. Substrate type and colour had a significant effect on the detection of the biological fluid, with limited fluid detection on darker substrates. The unique real-time High Dynamic range (HDR) ability of the SceneCam significantly enhanced the detection of biological fluids where background fluorescence masked target fluorescence. These preliminary results are presented as a proof of concept for combining 360° photography using HDR and an ALS for the detection of biological stains, within a scene, in real time, whilst conveying spatial relationships of staining to other evidence. This technique presents the opportunity to presumptively screen a crime scene for biological fluids and will facilitate simultaneous location and visualisation of biological evidence

    Simultaneous detection and image capture of biological evidence using a combined 360<sup>°</sup>camera system with single wavelength laser illumination

    Get PDF
    The Chartered Society of Forensic Sciences Forensic investigators frequently utilise light sources to detect and presumptively identify biological evidence. The instrumentation typically deploys single or multiple wavelength exposures at various intensities, which interact with constituents of biological material, initiating fluorescence or improving contrast between the material and substrate. Documentation using sketches and/or photographic approaches follows detection, which are essential for scene reconstruction. Recent research has demonstrated the simultaneous detection and capture of biological evidence using a 360° camera system combined with an alternate light source exhibiting broad wavelength ranges of light. Single wavelength light sources reportedly offer enhanced sensitivity, due to the increased light intensity and narrower bandwidth of light, although their combined use with a 360° camera system has not yet been explored. Samples of human blood, semen, saliva, and latent fingermarks were deposited on to a variety of substrates. A 360° camera system combined with a laser light source was used to detect and capture the samples. Ten participants were asked to detect the samples on images of the substrates without ground truth knowledge. It was possible to detect and capture biological evidence, although success varied according to substrate colour and light intensity. Advantageously, presumptive screening for biological fluids and the simultaneous location and visualisation of such evidence as part of a 360° panorama of the scene for contextual purposes was permitted. There was no fluorescent response from the fingermarks, although the oblique lighting effects appeared sufficient to aid mark detection in some circumstances. The use of single wavelength illumination clearly facilitates identification of a range of forensically important material. When coupled with a 360-degree camera, this allows for simultaneous identification and recording of such evidence in the context of the whole environment. © 201

    Measurement of blood pressure in the leg - a statement on behalf of the British and Irish Hypertension Society

    Get PDF
    This is the final version. Available on open access from Springer Nature via the DOI in this recordAnkle blood pressure (BP) measurement is necessary for the diagnosis of hypertension where measurements are not possible due to medical conditions or limb deformities. Based on a recent review of the evidence, we recommend an ankle BP threshold of ≥155/90 mmHg to define high blood pressure in patients who do not have vascular disease. We recommend that ankle BP readings are taken with the subject lying down, using a validated automated device with the cuff placed around the ankle/lower calf.Wellcome TrustRoyal SocietyNational Institute for Health Research (NIHR

    Validation of the Kinetik Blood Pressure Monitor-Series 1 for use in adults at home and in clinical settings, according to the 2002 European Society of Hypertension International Protocol on the validation of blood pressure devices

    Get PDF
    The aim of this study was to assess the blood pressure (BP) measurement accuracy of the Kinetik Blood Pressure Monitor—Series 1 (BPM-1) for use in home or clinical settings according to the 2002 European Society of Hypertension International Protocol (ESH-IP). Forty-two participants were recruited to fulfil the required number of systolic and diastolic BP measurements according to the ESH-IP. Nine sequential same-arm BP readings were measured and analysed for each participant using the test device and observer mercury standard readings according to the 2002 ESH-IP. Forty one participants were used to obtain 33 sets of systolic and diastolic BP readings and were included in the analysis. Mean difference between the device measurements and the observer (mercury standard) measurements was 1.1 ± 7.2/1.1 ± 6.8 mmHg (mean ± standard deviation; systolic/diastolic). The number of systolic BP differences between the test and observer measurements that fell within 5, 10 and 15 mmHg was 65, 86 and 92. For diastolic readings, the number of test—observer measurement differences within 5, 10 and 15 mmHg was 77, 91 and 94. The number of participants with at least two out of three differences within 5 mmHg was 28 for systolic and 40 for diastolic BP readings. Three participants had no differences between the test and observer measurements within 5 mmHg in both the systolic and diastolic measurement categories. The Kinetik BPM-1 device fulfilled the requirements of the ESH-IP validation procedure and can be recommended for clinical use and self-measurement within the home

    What The Oregon Health Study Can Tell Us About Expanding Medicaid

    Get PDF
    The recently enacted Patient Protection and Affordable Care Act includes a major expansion of Medicaid to low-income adults in 2014. This paper describes the Oregon Health Study, a randomized controlled trial that will be able to shed some light on the likely effects of such expansions. In 2008, Oregon randomly drew names from a waiting list for its previously closed public insurance program. Our analysis of enrollment into this program found that people who signed up for the waiting list and enrolled in the Oregon Medicaid program were likely to have worse health than those who did not. However, actual enrollment was fairly low, partly because many applicants did not meet eligibility standards.United States. Dept. of Health and Human Services. Office of the Assistant Secretary for Planning and EvaluationCalifornia HealthCare FoundationJohn D. and Catherine T. MacArthur FoundationNational Institute on AgingRobert Wood Johnson FoundationAlfred P. Sloan FoundationUnited States. Social Security Administratio

    Innate immune signaling in hearts and buccal mucosa cells of patients with arrhythmogenic cardiomyopathy

    Get PDF
    Background: Nuclear factor κB (NF-κB) signaling in cardiac myocytes causes disease in a mouse model of arrhythmogenic cardiomyopathy (ACM) by mobilizing CCR2-expressing macrophages that promote myocardial injury and arrhythmias. Buccal mucosa cells exhibit pathologic features similar to those seen in cardiac myocytes in patients with ACM. Objectives: We sought to determine if persistent innate immune signaling via NF-κB occurs in cardiac myocytes in patients with ACM and if this is associated with myocardial infiltration of proinflammatory cells expressing CCR2. We also determined if buccal mucosa cells from young subjects with inherited disease alleles exhibit NF-κB signaling. Methods: We analyzed myocardium from ACM patients who died suddenly or required cardiac transplantation. We also analyzed buccal mucosa cells from young subjects with inherited disease alleles. The presence of immunoreactive signal for RelA/p65 in nuclei of cardiac myocytes and buccal cells was used as a reliable indicator of active NF-κB signaling. We also counted myocardial CCR2-expressing cells. Results: RelA/p65 signal was seen in numerous cardiac myocyte nuclei in 34 of 36 cases of ACM but not in 19 age-matched control individuals. Cells expressing CCR2 were increased in patient hearts in numbers directly correlated with the number of cardiac myocytes showing NF-κB signaling. NF-κB signaling was observed in buccal cells in young subjects with active disease. Conclusions: Patients with clinically active ACM exhibit persistent innate immune responses in cardiac myocytes and buccal mucosa cells, reflecting a local and systemic inflammatory process. Such individuals may benefit from anti-inflammatory therapy

    Analysis of buccal mucosa as a prognostic tool in children with arrhythmogenic cardiomyopathy

    Get PDF
    Background The diagnosis of arrhythmogenic cardiomyopathy (ACM) is challenging especially in children at risk of adverse events. Analysis of cardiac myocyte junctional protein distribution may have diagnostic and prognostic implications, but its utility is limited by the need for a myocardial sample. We previously reported that buccal mucosa cells show junctional protein redistribution similar to that seen in cardiac myocytes of adult patients with ACM. Objectives We aimed to determine when junctional protein distribution abnormalities first occur in children with ACM variants and whether they correlate with progression of clinically apparent disease. Methods We analyzed buccal mucosa samples of children and adolescents with a family history of ACM (n = 13) and age-matched controls (n = 13). Samples were immunostained for plakoglobin, desmoplakin, plakophilin-1 and connexin43 and analyzed by confocal microscopy. All participants were swabbed at least twice with an average interval of 12–18 months between samplings. Results Junctional protein re-localization in buccal mucosa cells did not correlate with the presence of ACM-causing variants but instead occurred with clinical onset of disease. No changes in protein distribution were seen unless and until there was clinical evidence of disease. In addition, progressive shifts in the distribution of key proteins correlated with worsening of the disease phenotype. Finally, we observed restoration of junctional signal for Cx43 in patient with a favorable response to anti-arrhythmic therapy. Conclusions Due to ethical concerns about obtaining heart biopsies in children with no apparent disease, it has not been possible to analyze molecular changes in cardiac myocytes with the onset/progression of clinical disease. Using buccal smears as a surrogate for the myocardium may facilitate future studies of mechanisms and pathophysiological consequences of junctional protein redistribution in ACM. Buccal cells may also be a safe and inexpensive tool for risk stratification and potentially monitoring response to treatment in children bearing ACM variants

    Mitochondrial and nuclear genes suggest that stony corals are monophyletic but most families of stony corals are not (Order Scleractinia, Class Anthozoa, Phylum Cnidaria)

    Get PDF
    Modern hard corals (Class Hexacorallia; Order Scleractinia) are widely studied because of their fundamental role in reef building and their superb fossil record extending back to the Triassic. Nevertheless, interpretations of their evolutionary relationships have been in flux for over a decade. Recent analyses undermine the legitimacy of traditional suborders, families and genera, and suggest that a non-skeletal sister clade (Order Corallimorpharia) might be imbedded within the stony corals. However, these studies either sampled a relatively limited array of taxa or assembled trees from heterogeneous data sets. Here we provide a more comprehensive analysis of Scleractinia (127 species, 75 genera, 17 families) and various outgroups, based on two mitochondrial genes (cytochrome oxidase I, cytochrome b), with analyses of nuclear genes (ßtubulin, ribosomal DNA) of a subset of taxa to test unexpected relationships. Eleven of 16 families were found to be polyphyletic. Strikingly, over one third of all families as conventionally defined contain representatives from the highly divergent "robust" and "complex" clades. However, the recent suggestion that corallimorpharians are true corals that have lost their skeletons was not upheld. Relationships were supported not only by mitochondrial and nuclear genes, but also often by morphological characters which had been ignored or never noted previously. The concordance of molecular characters and more carefully examined morphological characters suggests a future of greater taxonomic stability, as well as the potential to trace the evolutionary history of this ecologically important group using fossils

    Generalizability of Blood Pressure Lowering Trials to Older Patients: Cross‐Sectional Analysis

    Get PDF
    BACKGROUND/OBJECTIVES: Randomized controlled trials are used to inform clinical guidelines on the management of hypertension in older adults, but it is unclear to what extent these trials represent the general population attending routine clinical practice. This study aimed to define the proportion and characteristics of patients eligible for hypertension trials conducted in older people. DESIGN: Cross‐sectional study. SETTING: A total of 24 general practices in England. PARTICIPANTS: Anonymized electronic health record data from all individuals aged 80 and older. MEASUREMENTS: Descriptive statistics were used to define the proportion and characteristics of patients eligible for two previous medication intensification trials (HYVET, SPRINT) and one medication reduction trial (OPTiMISE). A logistic regression model was constructed to estimate predictors of eligibility for each trial. RESULTS: Of 15,376 patients identified, 268 (1.7%; 95% confidence interval [CI] = 1.5–2.0%), 5,290 (34.4%; 95%CI = 33.7–35.2%), and 3,940 (25.6%; 95%CI = 24.9–26.3%) were eligible for the HYVET, SPRINT, and OPTiMISE trials, respectively. Between 5.6% and 30.7% of exclusions from each trial were due to eligibility criteria excluding those with high or uncontrolled blood pressure. Frailty (odds ratio [OR] = .44; 95%CI = .36–.54 [OPTiMISE]), cardiovascular polypharmacy (OR = .61; 95%CI = .55–.68 [SPRINT]) and multimorbidity (OR = .72; 95%CI = .64–.82 [SPRINT]) were associated with a lower likelihood of being eligible for one or more of the trials. CONCLUSION: A possible unintended consequence of blood pressure criteria used by trials attempting to answer different primary questions is that for many older patients, no trial evidence exists to inform treatment decisions in routine practice. Caution should be exercised when applying results from existing trials to patients with frailty or multimorbidity
    corecore