710 research outputs found

    Effect of Impurity Scattering on the Nonlinear Microwave Response in High-Tc Superconductors

    Get PDF
    We theoretically investigate intermodulation distortion in high-Tc superconductors. We study the effect of nonmagnetic impurities on the real and imaginary parts of nonlinear conductivity. The nonlinear conductivity is proportional to the inverse of temperature owing to the dependence of the damping effect on energy, which arises from the phase shift deviating from the unitary limit. It is shown that the final-states interaction makes the real part predominant over the imaginary part. These effects have not been included in previous theories based on the two-fluid model, enabling a consistent explanation for the experiments with the rf and dc fields

    Seismic reflection imaging of mixing processes in Fram Strait

    Get PDF
    The West Spitsbergen Current, which flows northward along the western Svalbard continental slope, transports warm and saline Atlantic water (AW) into the Arctic Ocean. A combined analysis of high-resolution seismic images and hydrographic sections across this current has uncovered the oceanographic processes involved in horizontal and vertical mixing of AW. At the shelf break, where a strong horizontal temperature gradient exists east of the warmest AW, isopycnal interleaving of warm AW and surrounding colder waters is observed. Strong seismic reflections characterize these interleaving features, with a negative polarity reflection arising from an interface of warm water overlying colder water. A seismic-derived sound speed image reveals the extent and lateral continuity of such interleaving layers. There is evidence of obliquely aligned internal waves emanating from the slope at 450–500 m. They follow the predicted trajectory of internal S2 tidal waves and can promote vertical mixing between Atlantic and Arctic-origin waters

    On-Loom, Real-Time, Noncontact Detection of Fabric Defects by Ultrasonic Imaging

    Get PDF
    The textile industries of developed nations, such as the United States and the countries of western Europe, are now facing enormous competition from imported fabrics important that the textile manufactures, as well as the machine manufactures, to manufacture a machine with high output, less waste, and individual-machine automation. One of the most labor-intensive tasks in textile production is the inspection and identification of fabric defects. Although visual inspection can identify most defects, an automated or semiautomated inspection system will be more reliable, eliminate potential human errors, improve quality control, reduce waste and energy consumption, and lower operating costs. Currently, an optic/visual system is commercially available, but it is an off-loom system and is very expensive. Other techniques, for example, ultrasonic, millimeter wave, capacitance, and photo-diode, have been studied. At Argonne National Laboratory (ANL), we developed a nonvisual, noncontact fabric-inspection system that can detects defects in real-time on the loom[1]. The system is compact, rugged, and low cost, requires minimal maintenance, is not sensitive to fabric color and vibration, and can easily be adapted to current loom configurations. Unlike other available techniques, the ANL ultrasonic system is not affected by vibration generated by the weaving machine

    Proteome Profiling of Breast Tumors by Gel Electrophoresis and Nanoscale Electrospray Ionization Mass Spectrometry

    Get PDF
    We have conducted proteome-wide analysis of fresh surgery specimens derived from breast cancer patients, using an approach that integrates size-based intact protein fractionation, nanoscale liquid separation of peptides, electrospray ion trap mass spectrometry, and bioinformatics. Through this approach, we have acquired a large amount of peptide fragmentation spectra from size-resolved fractions of the proteomes of several breast tumors, tissue peripheral to the tumor, and samples from patients undergoing noncancer surgery. Label-free quantitation was used to generate protein abundance maps for each proteome and perform comparative analyses. The mass spectrometry data revealed distinct qualitative and quantitative patterns distinguishing the tumors from healthy tissue as well as differences between metastatic and non-metastatic human breast cancers including many established and potential novel candidate protein biomarkers. Selected proteins were evaluated by Western blotting using tumors grouped according to histological grade, size, and receptor expression but differing in nodal status. Immunohistochemical analysis of a wide panel of breast tumors was conducted to assess expression in different types of breast cancers and the cellular distribution of the candidate proteins. These experiments provided further insights and an independent validation of the data obtained by mass spectrometry and revealed the potential of this approach for establishing multimodal markers for early metastasis, therapy outcomes, prognosis, and diagnosis in the future. © 2008 American Chemical Society

    Two-Proton Correlations from 14.6A GeV/c Si+Pb and 11.5A GeV/c Au+Au Central Collisions

    Full text link
    Two-proton correlation functions have been measured in Si+Pb collisions at 14.6A GeV/c and Au+Au collisions at 11.5A GeV/c by the E814/E877 collaboration. Data are compared with predictions of the transport model RQMD and the source size is inferred from this comparison. Our analysis shows that, for both reactions, the characteristic size of the system at freeze-out exceeds the size of the projectile, suggesting that the fireball created in the collision has expanded. For Au+Au reactions, the observed centrality dependence of the two-proton correlation function implies that more central collisions lead to a larger source sizes.Comment: RevTex, 12 pages, 5 figure

    Solving parabolic equations on the unit sphere via Laplace transforms and radial basis functions

    Full text link
    We propose a method to construct numerical solutions of parabolic equations on the unit sphere. The time discretization uses Laplace transforms and quadrature. The spatial approximation of the solution employs radial basis functions restricted to the sphere. The method allows us to construct high accuracy numerical solutions in parallel. We establish L2L_2 error estimates for smooth and nonsmooth initial data, and describe some numerical experiments.Comment: 26 pages, 1 figur

    Particles at oil–air surfaces : powdered oil, liquid oil marbles, and oil foam

    Get PDF
    The type of material stabilized by four kinds of fluorinated particles (sericite and bentonite platelet clays and spherical zinc oxide) in air–oil mixtures has been investigated. It depends on the particle wettability and the degree of shear. Upon vigorous agitation, oil dispersions are formed in all the oils containing relatively large bentonite particles and in oils of relatively low surface tension (γla < 26 mN m⁻¹) like dodecane, 20 cS silicone, and cyclomethicone containing the other fluorinated particles. Particle-stabilized oil foams were obtained in oils having γla > 26 mN m⁻¹ where the advancing air–oil–solid contact angle θ lies between ca. 90° and 120°. Gentle shaking, however, gives oil-in-air liquid marbles with all the oil–particle systems except for cases where θ is <60°. For oils of tension >24 mN m⁻¹ with omniphobic zinc oxide and sericite particles for which advancing θ ≥ 90°, dry oil powders consisting of oil drops in air which do not leak oil could be made upon gentle agitation up to a critical oil:particle ratio (COPR). Above the COPR, catastrophic phase inversion of the dry oil powders to air-in-oil foams was observed. When sheared on a substrate, the dry oil powders containing at least 60 wt % of oil release the encapsulated oil, making these materials attractive formulations in the cosmetic and food industries

    Tear secretion dysfunction among women workers engaged in light-on tests in the TFT-LCD industry

    Get PDF
    BACKGROUND: The TFT-LCD (thin film transistor liquid crystal display) industry is rapidly growing in Taiwan and many other countries. A large number of workers, mainly women, are employed in the light-on test process to detect the defects of products. At the light-on test workstation, the operator is generally exposed to low humidity (in the clean room environment), flashing light, and low ambient illumination for long working hours. Many workers complained about eye discomfort, and therefore we conducted a study to evaluate the tear secretion function of light-on test workers of a TFT-LCD company. METHODS: We recruited workers engaged in light-on tests in the company during their periodical health examination. In addition to a questionnaire survey of demographic characteristics and ophthalmic symptoms, we evaluated the tear secretion function of both eyes of each participant using the Schirmer's lacrimal basal secretion test with anaesthesia. A participant with one or both eyes yielding abnormal test results was defined as a case of tear secretion dysfunction. RESULTS: During the study period, a total of 371 light-on test workers received the health examination at the clinic of the park, and 52 of them were excluded due to having ophthalmic diseases and other systemic diseases that may affect ophthalmic function. All the remaining 319 qualified workers agreed to participate in this study, and they were all females working by 4-shift rotations. The average age was 24.2 years old (standard deviation [SD] = 3.8), and the average employment duration was 13.6 months (SD = 5.7). Among the 11 ophthalmic symptoms evaluated, eye dryness was the most prevalent (prevalence = 43.3%). In addition, the prevalence of tear secretion dysfunction in at least one eye was 40.1% (128 cases), and contact lens users had an odds ratio of 1.73 (95% confidence interval = 1.02–2.94) in comparison with non-contact lens users. Comparing the Schirmer's test results of those who also participated in the screening in the previous year, we found 40 of the 156 participants (17.2%) with normal test results in the previous year turned abnormal in 2001. In contrast, only 21 of the 76 participants (9.1%) with abnormal test results in the previous year turned normal, and the difference was statistically significant (p = 0.02 for McNemar's test). CONCLUSION: The prevalence of tear secretion dysfunction in woman workers engaged in light-on tests is high and increases with a one-year duration of employment. The use of contact lens may further increase the risk
    corecore