94 research outputs found

    Poor results of drilling in early stages of juxta-articular osteonecrosis in 12 joints affected by Gaucher disease

    Get PDF
    Background and purpose Gaucher disease is heterogeneous. One of the most devastating complications is bone involvement, ranging from mild osteopenia to osteonecrosis, but no markers have been discovered to predict onset and/or progression. We describe our experience in a large referral center using drilling for juxta-articular osteonecrosis in young patients with Gaucher disease

    Are component positioning and prosthesis size associated with hip resurfacing failure?

    Get PDF
    BACKGROUND: Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. METHODS: We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months). Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. RESULTS: Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters). CONCLUSIONS: These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve

    Sex differences in the morphological failure patterns following hip resurfacing arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Metal-on-metal hybrid hip resurfacing arthroplasty (with a cementless acetabular component and a cemented femoral component) is offered as an alternative to traditional total hip arthroplasty for the young and active adult with advanced osteoarthritis. Although it has been suggested that women are less appropriate candidates for metal-on-metal arthroplasty, the mechanisms of prosthesis failure has not been fully explained. While specific failure patterns, particularly osteonecrosis and delayed type hypersensitivity reactions have been suggested to be specifically linked to the sex of the patient, we wished to examine the potential influence of sex, clinical diagnosis, age of the patient and the size of the femoral component on morphological failure patterns in a large cohort of retrieved specimens following aseptic failure of hip resurfacing arthroplasty.</p> <p>Methods</p> <p>Femoral remnants retrieved from 173 hips with known patient's sex were morphologically analyzed for the cause of failure. The results were compared with the control group of the remaining 31 failures from patients of unknown sex. The odds ratios (OR) and 95% confidence intervals (CI) of the following morphologically defined variables were calculated using logistic regression analysis: periprosthetic fractures (n = 133), osteonecrosis (n = 151), the presence of excessive intraosseous lymphocyte infiltration (n = 11), and interface hyperosteoidosis (n = 30). Logistic regression analysis was performed both unadjusted and after adjustment for sex, age, the size of the femoral component, and preoperative clinical diagnosis.</p> <p>Results</p> <p>Femoral remnants from female patients had a smaller OR for fracture (adjusted OR: 0.29, 95% CI 0.11, 0.80, <it>P </it>for difference = 0.02) and for the presence of osteonecrosis (adjusted OR: 0.16, 95% CI 0.04, 0.63, <it>P </it>for difference = 0.01). However, women had a higher OR for both the presence of excessive intraosseous lymphocyte infiltration (adjusted OR: 10.22, 95% CI 0.79, 132.57, <it>P </it>for difference = 0.08) and interface hyperosteoidosis (adjusted OR: 4.19, 95% CI 1.14, 15.38, <it>P </it>for difference = 0.03).</p> <p>Conclusions</p> <p>Within the limitations of this study, we demonstrated substantial sex differences in distinct failure patterns of metal-on-metal hip resurfacing. Recognition of pathogenically distinct failure modes will enable further stratification of risk factors for certain failure mechanisms and thus affect future therapeutic options for selected patient groups.</p

    A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS). Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre.</p> <p>Methods</p> <p>A custom made neck jig device is presented as well as the results of a pilot study.</p> <p>The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned.</p> <p>Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation.</p> <p>Results</p> <p>The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife contact with femoral head, positive. There were no guide failures. The jig unique position and the number of steps required to put the guide in place were rated 1, while the complexity to put the guide into place was rated 1-2. In all five cases the guide wire was accurately positioned. Maximum angular deviation was 2.9° and maximum distance between insertion points was 2.1 mm.</p> <p>Conclusions</p> <p>Pilot testing of a custom made jig for use during SRA indicated that the device was (1) successfully applied and user friendly and (2) allowed for accurate guide wire placement according to the preoperative plan.</p

    Seroprevalence and distribution of arboviral infections among rural Kenyan adults: A cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Arthorpod-borne viruses (arboviruses) cause wide-spread morbidity in sub-Saharan Africa, but little research has documented the burden and distribution of these pathogens.</p> <p>Methods</p> <p>Using a population-based, cross-sectional study design, we administered a detailed questionnaire and used ELISA to test the blood of 1,141 healthy Kenyan adults from three districts for the presence of anti-viral Immunoglobulin G (IgG) antibodies to the following viruses: dengue (DENV), West Nile (WNV), yellow fever (YFV), Chikungunya (CHIKV), and Rift Valley fever (RVFV).</p> <p>Results</p> <p>Of these, 14.4% were positive for DENV, 9.5% were WNV positive, 9.2% were YFV positive, 34.0% were positive for CHIKV and 0.7% were RVFV positive. In total, 46.6% had antibodies to at least one of these arboviruses.</p> <p>Conclusions</p> <p>For all arboviruses, district of residence was strongly associated with seropositivity. Seroprevalence to YFV, DENV and WNV increased with age, while there was no correlation between age and seropositivity for CHIKV, suggesting that much of the seropositivity to CHIKV is due to sporadic epidemics. Paradoxically, literacy was associated with increased seropositivity of CHIKV and DENV.</p

    Vernonia cinerea Less. supplementation and strenuous exercise reduce smoking rate: relation to oxidative stress status and beta-endorphin release in active smokers

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>The aim of this study was to evaluate the effects of <it>Vernonia cinerea </it>Less. (VC) supplementation and exercise on oxidative stress biomarkers, beta-endorphin release, and the rate of cigarette smoking.</p> <p>Methods</p> <p>Volunteer smokers were randomly divided into four groups: group 1: VC supplement; group 2: exercise with VC supplement; group 3: exercise; and group 4: control. VC was prepared by wash and dry techniques and taken orally before smoking, matching the frequency of strenuous exercise (three times weekly). Before and after a two month period, exhaled carbon monoxide (CO), blood oxidative stress (malondialdehyde [MDA], nitric oxide [NOx], protein hydroperoxide [PrOOH] and total antioxidant capacity [TAC]), beta-endorphin and smoking rate were measured, and statistically analyzed.</p> <p>Results</p> <p>In Group 1, MDA, PrOOH, and NOx significantly decreased, whereas TAC increased (p < 0.05). In Group 2, MDA and PrOOH decreased (p < 0.05), with no other changes noted (p > 0.05). In Group 3, MDA, PrOOH, NOx, TAC, and beta-endorphin levels increased significantly (p < 0.05). Group 4 showed no change in oxidative stress variables or beta-endorphine levels (p > 0.05). All groups had lower levels of CO after the intervention. The smoking rate for light cigarette decreased in group 2(62.7%), 1(59.52%), 3 (53.57%) and 4(14.04%), whereas in self-rolled cigarettes it decreased in group 1 (54.47%), 3 (42.30%), 2 (40%) and 4 (9.2%).</p> <p>Conclusion</p> <p>Supplementation with <it>Vernonia cinerea </it>Less and exercise provided benefit related to reduced smoking rate, which may be related to oxidaive stress and beta-endorphine levels.</p

    Dutch guideline on total hip prosthesis

    Get PDF
    Contains fulltext : 97840.pdf (publisher's version ) (Open Access

    Physical and sports activity after hip arthroplasty

    Get PDF
    A artroplastia é utilizada para reconstrução da articulação do quadril, visando minimizar a dor e possibilitar o retorno às atividades de vida diária, esportivas e de lazer. O objetivo deste artigo é analisar na literatura as indicações e contraindicações referentes à prática de atividade física, esportiva e lazer após a artroplastia de quadril. Essa revisão aborda estudos publicados entre os anos de 1980 e 2009, obtidos por buscas em bancos de dados eletrônicos Medline, Scielo, Ovid, Infomaworld, Sciencedirect, Springerlink, Interscience, Sportdiscuss, Bireme, Informglobal, Opas, Ovid, Diseasedex, Eric, que totalizaram 39 artigos. Os artigos analisados apontam para a utilização de atividade física, esportiva e de lazer de baixo impacto. como a caminhada, natação, boliche, ciclismo, dentre outras. Outra indicação constatada na literatura é a utilização da atividade física e esportiva visando à manutenção do condicionamento físico, qualidade óssea e controle do peso corporal. Há ressalvas na literatura sobre a utilização de atividades de alto impacto, esporte com giro como o basquete e futebol ou com grande intensidade como tênis e a corrida, bem como os esportes de luta. As atividades físicas, esportivas e de lazer mais indicadas após uma atroplastia de quadril são as de baixo impacto como a hidroginástica, natação, caminhada, dentre outras. O início dessas atividades deve aguardar a liberação do médico, mas em média iniciam 60 dias após a cirurgia.Hip arthroplasty is used for reconstruction of the hip joint to reduce pain and to make the return to daily life, physical, sports and leisure activities possible. The objective of this article was to analyze in the literature the indications and counter-indications referring to practice of physical, sportive and leisure activities after hip arthroplasty. This revision approaches studies published between 1980 and 2009, obtained in searches in the Medline, Scielo, Ovid, Infomaworld, Sciencedirect, Springerlink, Interscience, Sportdiscuss, Bireme, Informglobal, Opas, Ovid, Diseasedex and Erics electronic databases with a total of 39 articles. The analyzed articles point to the use of physical, leisure and sports of low impact activities such as walking, swimming, bowling, cycling and others. Another indication evidenced in the literature is the use of physical and sportive activity aiming at the maintenance of physical fitness, bone quality and body weight control. The literature shows concerns with the use of activities of high impact or with great intensity like tennis and jogging, as well as fights
    corecore