126 research outputs found

    Counterion Effects on Nano-confined Metal-Drug-DNA Complexes

    Full text link
    We have explored morphology of DNA molecules bound with Cu-complexes of piroxicam molecules, a non-steroidal anti-inflammatory drug (NSAID), under one-dimensional confinement of thin films and have studied the effect of counterions present in a buffer. X-ray reflectivity at and away from the Cu K absorption edge and atomic force microscopy studies reveal that confinement segregates the drug molecules preferentially in a top layer of the DNA film, and counterions enhance this segregation

    Lamellar-lamellar phase separation in phospholipid/salt/water system(Poster session 1, New Frontiers in Colloidal Physics : A Bridge between Micro- and Macroscopic Concepts in Soft Matter)

    Get PDF
    この論文は国立情報学研究所の電子図書館事業により電子化されました。リン脂質と一価塩を一定の割合で混合して形成したマルチラメラベシクルにおいて観測されるラメラーラメラ相分離(別の面間隔を持つ2種類のラメラ構造が共存する)の要因を明らかにするため、DPPCとNaClの混合系でのそれぞれのラメラ相の面間隔の温度変化に対する応答を、X線小角散乱をもちいて観測した。その結果、この相分離は一価塩濃度の濃いラメラ相と薄いラメラ相に相分離することにより引き起こされることが示唆された

    Tuning Neutron Resonance Spin-Echo Spectrometers with Pulsed Beams

    Get PDF
    The neutron spin-echo spectroscopy technique involving pulsed beams can be used to effectively access a wide range of space-time correlations of condensed matter. In this study, the features of this technique, in particular, the modulation of the intensity with zero effort (MIEZE) by using pulsed beams, which is based on the quantum-state manipulation of the neutron spin and energy, are comprehensively examined. A formulation of the MIEZE combined with the time of flight method (TOF MIEZE) is established by considering the characteristics of the pulsed neutron beams. Moreover, a parameter, namely, the detuning parameter, is introduced as a measure of the magnitude of detuning from the optimized instrumental state, known as the spin-echo condition. The phase and frequency shifts of the neutron intensity signals resulting from the TOF MIEZE under various configurations are investigated systematically. It is found that the detuning parameter equals the derivative of phase with respect to the TOF, whose zero-point corresponds to the spin-echo condition. The theoretical predictions on phase and frequency shifts by the established formulation are well validated by the experiments using an intense pulsed neutron source. The detuning parameter helps clarify the principle of the TOF MIEZE technique and can provide practical guidance regarding the implementation and optimization of spectrometers

    Gravitational time delay of light for various models of modified gravity

    Get PDF
    We reexamined the gravitational time delay of light, allowing for various models of modified gravity. We clarify the dependence of the time delay (and induced frequency shift) on modified gravity models and investigate how to distinguish those models, when light propagates in static spherically symmetric spacetimes. Thus experiments by radio signal from spacecrafts at very different distances from Sun and future space-borne laser interferometric detectors could be a probe of modified gravity in the solar system.Comment: 10 pages, 2 figures; title, abstract and text improved; accepted for publication in Phys. Lett.

    Development of Computer Control System for Neutron Spin Echo Spectrometer

    Get PDF
    We have developed a computer control system for a neutron spin echo spectrometer (NSE) which has been constructed at C_ cold neutron guide port of JRR-3M, JAERI. This system controls the current of coils, the measurements by counters and the pulse-motor-drivers using a personal computer. The current of the coils is controlled using GP-IB or the D/A converters equipped in the I/O box connected to the personal computer. The current can be inverted using a current invertor controlled by the computer. The computer gets the data from a He^3 detector or one dimensional position sensitive detector (1DPSD) and saves them into hard- or floppy- disks, prints out them or transfers to another computer connected through RS-232C which analyzes the data. The computer programs for this system called NSEC are made of an assembly of the several simple programs (command) which can be rearranged easily. An NSE mesurement can be carried out automatically using the Batch files composed of the commands. This system is very convenient for NSE measurements

    Increased predominance of the matured ventricular subtype in embryonic stem cell-derived cardiomyocytes in vivo

    Get PDF
    Accumulating evidence suggests that human pluripotent stem cell-derived cardiomyocytes can affect “heart regeneration”, replacing injured cardiac scar tissue with concomitant electrical integration. However, electrically coupled graft cardiomyocytes were found to innately induce transient post-transplant ventricular tachycardia in recent large animal model transplantation studies. We hypothesised that these phenomena were derived from alterations in the grafted cardiomyocyte characteristics. In vitro experiments showed that human embryonic stem cell-derived cardiomyocytes (hESC-CMs) contain nodal-like cardiomyocytes that spontaneously contract faster than working-type cardiomyocytes. When transplanted into athymic rat hearts, proliferative capacity was lower for nodal-like than working-type cardiomyocytes with grafted cardiomyocytes eventually comprising only relatively matured ventricular cardiomyocytes. RNA-sequencing of engrafted hESC-CMs confirmed the increased expression of matured ventricular cardiomyocyte-related genes, and simultaneous decreased expression of nodal cardiomyocyte-related genes. Temporal engraftment of electrical excitable nodal-like cardiomyocytes may thus explain the transient incidence of post-transplant ventricular tachycardia, although further large animal model studies will be required to control post-transplant arrhythmia

    Multicenter, single-blind, randomized controlled study of the efficacy and safety of favipiravir and nafamostat mesilate in patients with COVID-19 pneumonia

    Get PDF
    Objectives: To evaluate the efficacy and safety of nafamostat combined with favipiravir for the treatment of COVID-19. Methods: We conducted a multicenter, randomized, single-blind, placebo-controlled, parallel assignment study in hospitalized patients with mild-to-moderate COVID-19 pneumonia. Patients were randomly assigned to receive favipiravir alone (n = 24) or nafamostat with favipiravir (n = 21). The outcomes included changes in the World Health Organization clinical progression scale score, time to improvement in body temperature, and improvement in oxygen saturation (SpO2). Results: There was no significant difference in the changes in the clinical progression scale between nafamostat with favipiravir and favipiravir alone groups (median, -0.444 vs -0.150, respectively; least-squares mean difference, -0.294; P = 0.364). The time to improvement in body temperature was significantly shorter in the combination group (5.0 days; 95% confidence interval, 4.0-7.0) than in the favipiravir group (9.0 days; 95% confidence interval, 7.0-18.0; P =0.009). The changes in SpO2 were greater in the combination group than in the favipiravir group (0.526% vs -1.304%, respectively; least-squares mean difference, 1.831; P = 0.022). No serious adverse events or deaths were reported, but phlebitis occurred in 57.1% of the patients in the combination group. Conclusion: Although our study showed no differences in clinical progression, earlier defervescence, and recovery of SpO2 were observed in the combination group

    Coincidence analysis to search for inspiraling compact binaries using TAMA300 and LISM data

    Get PDF
    Japanese laser interferometric gravitational wave detectors, TAMA300 and LISM, performed a coincident observation during 2001. We perform a coincidence analysis to search for inspiraling compact binaries. The length of data used for the coincidence analysis is 275 hours when both TAMA300 and LISM detectors are operated simultaneously. TAMA300 and LISM data are analyzed by matched filtering, and candidates for gravitational wave events are obtained. If there is a true gravitational wave signal, it should appear in both data of detectors with consistent waveforms characterized by masses of stars, amplitude of the signal, the coalescence time and so on. We introduce a set of coincidence conditions of the parameters, and search for coincident events. This procedure reduces the number of fake events considerably, by a factor 104\sim 10^{-4} compared with the number of fake events in single detector analysis. We find that the number of events after imposing the coincidence conditions is consistent with the number of accidental coincidences produced purely by noise. We thus find no evidence of gravitational wave signals. We obtain an upper limit of 0.046 /hours (CL =90= 90 %) to the Galactic event rate within 1kpc from the Earth. The method used in this paper can be applied straightforwardly to the case of coincidence observations with more than two detectors with arbitrary arm directions.Comment: 28 pages, 17 figures, Replaced with the version to be published in Physical Review
    corecore