7 research outputs found

    Implementation of field detection devices for antimalarial quality screening in Lao PDR-A cost-effectiveness analysis

    No full text
    Substandard and falsified (SF) antimalarials have devastating consequences including increased morbidity, mortality and economic losses. Portable medicine quality screening devices are increasingly available, but whether their use for the detection of SF antimalarials is cost-effective is not known. We evaluated the cost-effectiveness of introducing such devices in post-market surveillance in pharmacies in Laos, conservatively focusing on their outcome in detecting SF artemisinin-based combination therapies (ACTs). We simulated the deployment of six portable screening devices: two handheld near-infrared [MicroPHAZIR RX, NIR-S-G1], two handheld Raman [Progeny, TruScan RM]; one portable mid-infrared [4500a FTIR] spectrometers, and single-use disposable paper analytical devices [PADs]. We considered two scenarios with high and low levels of SF ACTs. Different sampling strategies in which medicine inspectors would test 1, 2, or 3 sample(s) of each brand of ACT were evaluated. Costs of inspection including device procurement, inspector time, reagents, reference testing, and replacement with genuine ACTs were estimated. Outcomes were measured as disability adjusted life years (DALYs) and incremental cost-effectiveness ratios were estimated for each device compared with a baseline of visual inspections alone. In the scenario with high levels of SF ACTs, all devices were cost-effective with a 1-sample strategy. In the scenario of low levels of SF ACTs, only four devices (MicroPHAZIR RX, 4500a FTIR, NIR-S-G1, and PADs) were cost-effective with a 1-sample strategy. In the multi-way comparative analysis, in both scenarios the NIR-S-G1 testing 2 samples was the most cost-effective option. Routine inspection of ACT quality using portable screening devices is likely to be cost-effective in the Laos context. This work should encourage policy-makers or regulators to further investigate investment in portable screening devices to detect SF medicines and reduce their associated undesired health and economic burdens

    Evaluation of portable devices for medicine quality screening: Lessons learnt, recommendations for implementation, and future priorities

    No full text
    CĂ©line Caillet and co-authors discuss a Collection on use of portable devices for the evaluation of medicine quality and legitimacy

    A comparative field evaluation of six medicine quality screening devices in Laos

    No full text
    Background Medicine quality screening devices hold great promise for post-market surveillance (PMS). However, there is little independent evidence on their field utility and usability to inform policy decisions. This pilot study in the Lao PDR tested six devices’ utility and usability in detecting substandard and falsified (SF) medicines. Methodology/principal findings Observational time and motion studies of the inspections by 16 Lao medicine inspectors of 1) the stock of an Evaluation Pharmacy (EP), constructed to resemble a Lao pharmacy, and 2) a sample set of medicines (SSM); were conducted without and with six devices: four handheld spectrometers (two near infrared: MicroPHAZIR RX, NIR-S-G1 & two Raman: Progeny, Truscan RM); one portable mid-infrared spectrometer (4500a), and single-use paper analytical devices (PAD). User experiences were documented by interviews and focus group discussions. Significantly more samples were wrongly categorised as pass/fail with the PAD compared to the other devices in EP inspections (p<0.05). The numbers of samples wrongly classified in EP inspections were significantly lower than in initial visual inspections without devices for 3/6 devices (NIR-S-G1, MicroPHAZIR RX, 4500a). The NIR-S-G1 had the fastest testing time per sample (median 93.5 sec, p<0.001). The time spent on EP visual inspection was significantly shorter when using a device than for inspections without devices, except with the 4500a, risking missing visual clues of samples being SF. The main user errors were the selection of wrong spectrometer reference libraries and wrong user interpretation of PAD results. Limitations included repeated inspections of the EP by the same inspectors with different devices and the small sample size of SF medicines. Conclusions/significance This pilot study suggests policy makers wishing to implement portable screening devices in PMS should be aware that overconfidence in devices may cause harm by reducing inspectors’ investment in visual inspection. It also provides insight into the advantages/limitations of diverse screening devices in the hands of end-users

    Laboratory evaluation of twelve portable devices for medicine quality screening

    No full text
    Background Post-market surveillance is a key regulatory function to prevent substandard and falsified (SF) medicines from being consumed by patients. Field deployable technologies offer the potential for rapid objective screening for SF medicines. Methods and findings We evaluated twelve devices: three near infrared spectrometers (MicroPHAZIR RX, NIR-S-G1, Neospectra 2.5), two Raman spectrometers (Progeny, TruScan RM), one mid-infrared spectrometer (4500a), one disposable colorimetric assay (Paper Analytical Devices, PAD), one disposable immunoassay (Rapid Diagnostic Test, RDT), one portable liquid chromatograph (C-Vue), one microfluidic system (PharmaChk), one mass spectrometer (QDa), and one thin layer chromatography kit (GPHF-Minilab). Each device was tested with a series of field collected medicines (FCM) along with simulated medicines (SIM) formulated in a laboratory. The FCM and SIM ranged from samples with good quality active pharmaceutical ingredient (API) concentrations, reduced concentrations of API (80% and 50% of the API), no API, and the wrong API. All the devices had high sensitivities (91.5 to 100.0%) detecting medicines with no API or the wrong API. However, the sensitivities of each device towards samples with 50% and 80% API varied greatly, from 0% to 100%. The infrared and Raman spectrometers had variable sensitivities for detecting samples with 50% and 80% API (from 5.6% to 50.0%). The devices with the ability to quantitate API (C-Vue, PharmaChk, QDa) had sensitivities ranging from 91.7% to 100% to detect all poor quality samples. The specificity was lower for the quantitative C-Vue, PharmaChk, & QDa (50.0% to 91.7%) than for all the other devices in this study (95.5% to 100%). Conclusions The twelve devices evaluated could detect medicines with the wrong or none of the APIs, consistent with falsified medicines, with high accuracy. However, API quantitation to detect formulations similar to those commonly found in substandards proved more difficult, requiring further technological innovation

    Association of circulating miR-223 and miR-16 with disease activity in patients with early rheumatoid arthritis

    Get PDF
    BACKGROUND: Identification of parameters for early diagnosis and treatment response would be beneficial for patients with early rheumatoid arthritis (ERA) to prevent ongoing joint damage. miRNAs have features of potential biomarkers, and an altered expression of miRNAs was shown in established rheumatoid arthritis (RA). OBJECTIVE: To analyse RA associated miRNAs in the sera of patients with ERA to find markers of early disease, clinical activity or predictors of disease outcome. METHODS: Total RNA was isolated from whole sera in ERA patients (prior to and after 3 and 12 months of therapy with disease modifying antirheumatic drugs), in patients with established RA and in healthy controls (HC) using phenol-chloroform extraction. Expression of miR-146a, miR-155, miR-223, miR-16, miR-203, miR-132 and miR-124a was analysed by TaqMan Real Time PCR. RESULTS: From all analysed miRNAs, levels of miR-146a, miR-155 and miR-16 were decreased in the sera of ERA patients in comparison with established RA. A change in circulating miR-16 in the first 3 months of therapy was associated with a decrease in DAS28 in long term follow-up in ERA (p=0.002). Levels of circulating miR-223 in treatment naĂŻve ERA correlated with C reactive protein (p=0.008), DAS28 (p=0.031) and change in DAS28 after 3 months (p=0.003) and 12 months (p=0.011) of follow-up. However, neither miR-16 nor miR-223 could distinguish ERA from HC. CONCLUSIONS: Differential expression of circulating miR-146a, miR-155 and miR-16 in the sera of ERA patients may characterise an early stage of the disease. We suggest miR-223 as a marker of disease activity and miR-16 and miR-223 as possible predictors for disease outcome in ERA