10 research outputs found

    Brain Tumor Vascular Network Segmentation from Micro-Tomography

    Get PDF
    Micro-tomography produces high resolution images of bio- logical structures such as vascular networks. In this paper, we present a new approach for segmenting vascular network into pathological and normal regions from considering their micro-vessel 3D structure only. We deïŹne and use a condi- tional random ïŹeld for segmenting the output of a watershed algorithm. The tumoral and normal classes are thus character- ized by their respective distribution of watershed region size interpreted as local vascular territories

    Vascular network segmentation: an unsupervised approach

    Get PDF
    Micro-tomography produces high resolution images of biological structures such as vascular networks. In this paper, we present a new approach for segmenting vascular network into pathological and normal regions from considering their micro-vessel 3D structure only. We consider a partition of the volume obtained by a watershed algorithm based on the distance from the nearest vessel. Each territory is characterized by its volume and the local vascular density. The volume and density maps are first regularized by minimizing the total variation. Then, a new approach is proposed to segment the volume from the two previous restored images based on hypothesis testing. Results are presented on 3D micro-tomographic images of the brain micro-vascular network

    Chalcone JAI-51 improves efficacy of synchrotron microbeam radiation therapy of brain tumors.

    Get PDF
    International audienceMicrobeam radiation therapy (MRT), a preclinical form of radiosurgery, uses spatially fractionated micrometre-wide synchrotron-generated X-ray beams. As MRT alone is predominantly palliative for animal tumors, the effects of the combination of MRT and a newly synthesized chemotherapeutic agent JAI-51 on 9L gliosarcomas have been evaluated. Fourteen days (D14) after implantation (D0), intracerebral 9LGS-bearing rats received either MRT, JAI-51 or both treatments. JAI-51, alone or immediately after MRT, was administered three times per week. Animals were kept up to ∌20 weeks after irradiation or sacrificed at D16 or D28 after treatment for cell cycle analysis. MRT plus JAI-51 increased significantly the lifespan compared with MRT alone (p = 0.0367). JAI-51 treatment alone had no effect on rat survival. MRT alone or associated with JAI-51 induced a cell cycle blockade in G2/M (p 8c). The combination of MRT and JAI-51 increases the survival of 9LGS-bearing rats by inducing endoreduplication of DNA and tumor cell death; further, it slowed the onset of tumor growth resumption two weeks after treatment

    Aberrant neuronal connectivity in the cortex drives generation of seizures in rat Absence Epilepsy

    No full text
    International audienceAbsence epilepsy belongs to genetic epilepsies and is characterized by recurrent generalized seizures that are concomitant with alterations of consciousness and associated with cognitive comorbidities. Little is known about the mechanisms leading to occurrence of epileptic seizures (i.e. epileptogenesis) and, in particular, it remains an open question as to whether neuronal hypersynchronization, a key feature in seizure initiation, could result from aberrant structural connectivity within neuronal networks endowing them with epileptic properties. In the present study, we addressed this question using a genetic model of absence epilepsy in the rat where seizures initiate in the whisker primary somatosensory cortex (wS1). We hypothesized that alterations in structural connectivity of neuronal networks within wS1 contribute to pathological neuronal synchronization responsible for seizures. First, we used rabies virus-mediated retrograde synaptic tracing and showed that cortical neurons located in both upper- and deep-layers of wS1 displayed aberrant and significantly increased connectivity in the genetic model of absence epilepsy, as highlighted by a higher number of presynaptic partners. Next, we showed at the functional level that disrupting these aberrant wS1 neuronal networks with synchrotron X-ray-mediated cortical microtransections drastically decreased both the synchronization and seizure power of wS1 neurons, as revealed by in vivo local field potential recordings with multichannel probes. Taken together, our data provide for the first time strong evidence that increased structural connectivity patterns of cortical neurons represent critical pathological substrates for increased neuronal synchronization and generation of absence seizures

    Permeability of Brain Tumor Vessels Induced by Uniform or Spatially Microfractionated Synchrotron Radiation Therapies.

    No full text
    PURPOSE To compare the blood-brain barrier permeability changes induced by synchrotron microbeam radiation therapy (MRT, which relies on spatial fractionation of the incident x-ray beam into parallel micron-wide beams) with changes induced by a spatially uniform synchrotron x-ray radiation therapy. METHODS AND MATERIALS Male rats bearing malignant intracranial F98 gliomas were randomized into 3 groups: untreated, exposed to MRT (peak and valley dose: 241 and 10.5 Gy, respectively), or exposed to broad beam irradiation (BB) delivered at comparable doses (ie, equivalent to MRT valley dose); both applied by 2 arrays, intersecting orthogonally the tumor region. Vessel permeability was monitored in vivo by magnetic resonance imaging 1 day before (T-1) and 1, 2, 7, and 14 days after treatment start. To determine whether physiologic parameters influence vascular permeability, we evaluated vessel integrity in the tumor area with different values for cerebral blood flow, blood volume, edema, and tissue oxygenation. RESULTS Microbeam radiation therapy does not modify the vascular permeability of normal brain tissue. Microbeam radiation therapy-induced increase of tumor vascular permeability was detectable from T2 with a maximum at T7 after exposure, whereas BB enhanced vessel permeability only at T7. At this stage MRT was more efficient at increasing tumor vessel permeability (BB vs untreated: +19.1%; P=.0467; MRT vs untreated: +44.8%; P<.0001), and its effects lasted until T14 (MRT vs BB, +22.6%; P=.0199). We also showed that MRT was more efficient at targeting highly oxygenated (high blood volume and flow) and more proliferative parts of the tumor than BB. CONCLUSIONS Microbeam radiation therapy-induced increased tumor vascular permeability is: (1) significantly greater; (2) earlier and more prolonged than that induced by BB irradiation, especially in highly proliferative tumor areas; and (3) targets all tumor areas discriminated by physiologic characteristics, including those not damaged by homogeneous irradiation

    Monocrystalline diamond detector for online monitoring during synchrotron microbeam radiotherapy

    No full text
    International audienceMicrobeam radiation therapy (MRT) is a radiotherapy technique combining spatial fractionation of the dose distribution on a micrometric scale, X-rays in the 50–500 keV range and dose rates up to 16 × 103 Gy s−1. Nowadays, in vivo dosimetry remains a challenge due to the ultra-high radiation fluxes involved and the need for high-spatial-resolution detectors. The aim here was to develop a striped diamond portal detector enabling online microbeam monitoring during synchrotron MRT treatments. The detector, a 550 ”m bulk monocrystalline diamond, is an eight-strip device, of height 3 mm, width 178 ”m and with 60 ”m spaced strips, surrounded by a guard ring. An eight-channel ASIC circuit for charge integration and digitization has been designed and tested. Characterization tests were performed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility (ESRF). The detector measured direct and attenuated microbeams as well as interbeam fluxes with a precision level of 1%. Tests on phantoms (RW3 and anthropomorphic head phantoms) were performed and compared with simulations. Synchrotron radiation measurements were performed on an RW3 phantom for strips facing a microbeam and for strips facing an interbeam area. A 2% difference between experiments and simulations was found. In more complex geometries, a preliminary study showed that the absolute differences between simulated and recorded transmitted beams were within 2%. Obtained results showed the feasibility of performing MRT portal monitoring using a microstriped diamond detector. Online dosimetric measurements are currently ongoing during clinical veterinary trials at ESRF, and the next 153-strip detector prototype, covering the entire irradiation field, is being finalized at our institution.</jats:p
    corecore