37 research outputs found

    A fast - Monte Carlo toolkit on GPU for treatment plan dose recalculation in proton therapy

    Get PDF
    In the context of the particle therapy a crucial role is played by Treatment Planning Systems (TPSs), tools aimed to compute and optimize the tratment plan. Nowadays one of the major issues related to the TPS in particle therapy is the large CPU time needed. We developed a software toolkit (FRED) for reducing dose recalculation time by exploiting Graphics Processing Units (GPU) hardware. Thanks to their high parallelization capability, GPUs significantly reduce the computation time, up to factor 100 respect to a standard CPU running software. The transport of proton beams in the patient is accurately described through Monte Carlo methods. Physical processes reproduced are: Multiple Coulomb Scattering, energy straggling and nuclear interactions of protons with the main nuclei composing the biological tissues. FRED toolkit does not rely on the water equivalent translation of tissues, but exploits the Computed Tomography anatomical information by reconstructing and simulating the atomic composition of each crossed tissue. FRED can be used as an efficient tool for dose recalculation, on the day of the treatment. In fact it can provide in about one minute on standard hardware the dose map obtained combining the treatment plan, earlier computed by the TPS, and the current patient anatomic arrangement

    Butyrylcholinesterase distribution in the mouse gastrointestinal tract: An immunohistochemical study

    Get PDF
    Butyrylcholinesterase (BChE) is a hydrolytic enzyme that together with acetylcholinesterase (AChE) belongs to the cholinesterase family. Whereas AChE has a well-established role in regulating cholinergic neurotransmission in central and peripheral synapses, the physiological role of BChE remains elusive. In this morphological immunohistochemical and double-label confocal microscopy study we investigated the distribution of BChE in the mouse gastrointestinal tract. BChE-positive cells were detected in the liver (both in hepatocytes and cholangiocytes), in the keratinised layers of the squamous epithelium of the oesophagus and forestomach, in the oxyntic mucosa of the stomach, in the mucus-secreting cells of duodenal Brunner glands and the small and large intestinal mucosa. Interestingly, BChE-positive cells were often detected close to gastrointestinal proliferative niches. In the oxyntic mucosa, the close proximity of ghrelin-producing and BChE-positive parietal cells suggests that BChE may be involved in ghrelin hydrolysation through paracrine action. To our knowledge, this is the first comprehensive morphological study performed to gain insight into the physiological role of BChE in the gastrointestinal tract

    A fast - Monte Carlo toolkit on GPU for treatment plan dose recalculation in proton therapy

    Get PDF
    In the context of the particle therapy a crucial role is played by Treatment Planning Systems (TPSs), tools aimed to compute and optimize the tratment plan. Nowadays one of the major issues related to the TPS in particle therapy is the large CPU time needed. We developed a software toolkit (FRED) for reducing dose recalculation time by exploiting Graphics Processing Units (GPU) hardware. Thanks to their high parallelization capability, GPUs significantly reduce the computation time, up to factor 100 respect to a standard CPU running software. The transport of proton beams in the patient is accurately described through Monte Carlo methods. Physical processes reproduced are: Multiple Coulomb Scattering, energy straggling and nuclear interactions of protons with the main nuclei composing the biological tissues. FRED toolkit does not rely on the water equivalent translation of tissues, but exploits the Computed Tomography anatomical information by reconstructing and simulating the atomic composition of each crossed tissue. FRED can be used as an efficient tool for dose recalculation, on the day of the treatment. In fact it can provide in about one minute on standard hardware the dose map obtained combining the treatment plan, earlier computed by the TPS, and the current patient anatomic arrangement

    Measurement of secondary particle production induced by particle therapy ion beams impinging on a PMMA target

    Get PDF
    Particle therapy is a technique that uses accelerated charged ions for cancer treatment and combines a high irradiation precision with a high biological effectiveness in killing tumor cells [1]. Informations about the secondary particles emitted in the interaction of an ion beam with the patient during a treatment can be of great interest in order to monitor the dose deposition. For this purpose an experiment at the HIT (Heidelberg Ion-Beam Therapy Center) beam facility has been performed in order to measure fluxes and emission profiles of secondary particles produced in the interaction of therapeutic beams with a PMMA target. In this contribution some preliminary results about the emission profiles and the energy spectra of the detected secondaries will be presente

    Measurement of charged particle yields from therapeutic beams in view of the design of an innovative hadrontherapy dose monitor

    Get PDF
    Particle Therapy (PT) is an emerging technique, which makes use of charged particles to efficiently cure different kinds of solid tumors. The high precision in the hadrons dose deposition requires an accurate monitoring to prevent the risk of under-dosage of the cancer region or of over-dosage of healthy tissues. Monitoring techniques are currently being developed and are based on the detection of particles produced by the beam interaction into the target, in particular: charged particles, result of target and/or projectile fragmentation, prompt photons coming from nucleus de-excitation and back-to-back γ s, produced in the positron annihilation from β + emitters created in the beam interaction with the target. It has been showed that the hadron beam dose release peak can be spatially correlated with the emission pattern of these secondary particles. Here we report about secondary particles production (charged fragments and prompt γ s) performed at different beam and energies that have a particular relevance for PT applications: 12C beam of 80 MeV/u at LNS, 12C beam 220 MeV/u at GSI, and 12C, 4He, 16O beams with energy in the 50–300 MeV/u range at HIT. Finally, a project for a multimodal dose-monitor device exploiting the prompt photons and charged particles emission will be presented

    Towards a Radio-guided Surgery with β\beta^{-} Decays: Uptake of a somatostatin analogue (DOTATOC) in Meningioma and High Grade Glioma

    Full text link
    A novel radio guided surgery (RGS) technique for cerebral tumors using β\beta^{-} radiation is being developed. Checking the availability of a radio-tracer that can deliver a β\beta^{-} emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.Comment: 21 pages, 5 figure

    Characterization of a detector for β− radio-guided surgery

    Get PDF
    This paper reports a new device for the radio-guided surgery technique exploiting β− emitters. A specific intraoperative β− detecting probe based on a low-density organic crystal, the diphenylbutadiene-doped para-therphenyl, coupled by optical fibres to a photomultiplier, was developed. A portable readout electronics was designed to provide the surgeons with multi real-time feedback. The aspects related to the applicability of the device, in particular the perception of the spatial resolution of the probe and the comprehension time necessary to the operator to interpret the system response were investigated. Preliminary promising results support the possibility of using this innovative probe in cancer surgery

    Smart Meter Awareness in Italy, Ancona

    No full text
    Smart meters, one of the crucial enablers of the smart-grid concept and cornerstones in smart planning for cities, offer the opportunity for consumers to address their energy consumption effectively through timely and accurate data on their energy usage. However, previous studies have shown that smart meters may not lead to the desired energy savings unless actively used by households. To this end, the research presented in this paper investigates the penetration of smart meters at community level and explores how such a metering system can help people to understand and manage their energy use better. It examines the awareness about smart meters, looks into their presence in current accommodation and focuses on the views people have about smart meters. For this purpose, a questionnaire was prepared and distributed to a group of individuals residing in the wide area of Ancona province in Italy. Although the deployment of modern second-generation smart meters started in 2017 replacing the outdated smart meters massively installed in the 2000s, the results show low-to-moderate levels of awareness of modern smart meters among the respondents and a low presence of second-generation metering devices in their current accommodation. However, the general view expressed by the participants about smart meters is positive. The findings demonstrate that respondents are in need not only of a gauge that measures energy consumption but also of a tool that assists them to manage effectively their energy use. © 2021, The Author(s)
    corecore