173 research outputs found
Source-receptor matrix calculation with a Source-receptor matrix calculation with a backward mode
International audienceThe possibility to calculate linear-source receptor relationships for the transport of atmospheric trace substances with a Lagrangian particle dispersion model (LPDM) running in backward mode is shown and presented with many tests and examples. The derivation includes the action of sources and of any first-order processes (transformation with prescribed rates, dry and wet deposition, radioactive decay, ...). The backward mode is computationally advantageous if the number of receptors is less than the number of sources considered. The combination of an LPDM with the backward (adjoint) methodology is especially attractive for the application to point measurements, which can be handled without artificial numerical diffusion. Practical hints are provided for source-receptor calculations with different settings, both in forward and backward mode. The equivalence of forward and backward calculations is shown in simple tests for release and sampling of particles, pure wet deposition, pure convective redistribution and realistic transport over a short distance. Furthermore, an application example explaining measurements of Cs-137 in Stockholm as transport from areas contaminated heavily in the Chernobyl disaster is included
Source-receptor matrix calculation with a Lagrangian particle dispersion model in backward mode
International audienceThe possibility to calculate linear-source receptor relationships for the transport of atmospheric trace substances with a Lagrangian particle dispersion model (LPDM) running in backward mode is shown and presented with many tests and examples. This mode requires only minor modifications of the forward LPDM. The derivation includes the action of sources and of any first-order processes (transformation with prescribed rates, dry and wet deposition, radioactive decay, etc.). The backward mode is computationally advantageous if the number of receptors is less than the number of sources considered. The combination of an LPDM with the backward (adjoint) methodology is especially attractive for the application to point measurements, which can be handled without artificial numerical diffusion. Practical hints are provided for source-receptor calculations with different settings, both in forward and backward mode. The equivalence of forward and backward calculations is shown in simple tests for release and sampling of particles, pure wet deposition, pure convective redistribution and realistic transport over a short distance. Furthermore, an application example explaining measurements of Cs-137 in Stockholm as transport from areas contaminated heavily in the Chernobyl disaster is included
Technical note: The Lagrangian particle dispersion model FLEXPART version 6.2
International audienceThe Lagrangian particle dispersion model FLEXPART was originally (about 8 years ago) designed for calculating the long-range and mesoscale dispersion of air pollutants from point sources, such as after an accident in a nuclear power plant. In the meantime FLEXPART has evolved into a comprehensive tool for atmospheric transport modeling and analysis. Its application fields were extended from air pollution studies to other topics where atmospheric transport plays a role (e.g., exchange between the stratosphere and troposphere, or the global water cycle). It has evolved into a true community model that is now being used by at least 25 groups from 14 different countries and is seeing both operational and research applications. A user manual has been kept actual over the years and was distributed over an internet page along with the model's source code. In this note we provide a citeable technical description of FLEXPART's latest version (6.2)
Cryptotomography: reconstructing 3D Fourier intensities from randomly oriented single-shot diffraction patterns
We reconstructed the 3D Fourier intensity distribution of mono-disperse
prolate nano-particles using single-shot 2D coherent diffraction patterns
collected at DESY's FLASH facility when a bright, coherent, ultrafast X-ray
pulse intercepted individual particles of random, unmeasured orientations. This
first experimental demonstration of cryptotomography extended the
Expansion-Maximization-Compression (EMC) framework to accommodate unmeasured
fluctuations in photon fluence and loss of data due to saturation or background
scatter. This work is an important step towards realizing single-shot
diffraction imaging of single biomolecules.Comment: 4 pages, 4 figure
Recommended from our members
United States Bureau of Mines Bulletin 88
From Introduction: "This report treats of method of preventing some of the waste of the natural gas incidental to oil mining. This method, the condensation of gasoline from natural gas, offers to the oil operator and others a profitable means of utilizing some of the oil-well gas now being wasted.
UV/Optical Detections of Candidate Tidal Disruption Events by GALEX and CFHTLS
We present two luminous UV/optical flares from the nuclei of apparently
inactive early-type galaxies at z=0.37 and 0.33 that have the radiative
properties of a flare from the tidal disruption of a star. In this paper we
report the second candidate tidal disruption event discovery in the UV by the
GALEX Deep Imaging Survey, and present simultaneous optical light curves from
the CFHTLS Deep Imaging Survey for both UV flares. The first few months of the
UV/optical light curves are well fitted with the canonical t^(-5/3) power-law
decay predicted for emission from the fallback of debris from a tidally
disrupted star. Chandra ACIS X-ray observations during the flares detect soft
X-ray sources with T_bb= (2-5) x 10^5 K or Gamma > 3 and place limits on hard
X-ray emission from an underlying AGN down to L_X (2-10 keV) <~ 10^41 ergs/s.
Blackbody fits to the UV/optical spectral energy distributions of the flares
indicate peak flare luminosities of > 10^44-10^45 ergs/s. The temperature,
luminosity, and light curves of both flares are in excellent agreement with
emission from a tidally disrupted main sequence star onto a central black hole
of several times 10^7 msun. The observed detection rate of our search over ~
2.9 deg^2 of GALEX Deep Imaging Survey data spanning from 2003 to 2007 is
consistent with tidal disruption rates calculated from dynamical models, and we
use these models to make predictions for the detection rates of the next
generation of optical synoptic surveys.Comment: 28 pages, 27 figures, 11 tables, accepted to ApJ, final corrections
from proofs adde
Largest M Dwarf Flares from ASAS-SN
The All-sky Automated Survey for Supernovae (ASAS-SN) is the only project in existence to scan the entire sky in optical light approximately every day, reaching a depth of g ~ 18 mag. Over the course of its first 4 yr of transient alerts (2013–2016), ASAS-SN observed 53 events classified as likely M dwarf flares. We present follow-up photometry and spectroscopy of all 53 candidates, confirming flare events on 47 M dwarfs, one K dwarf, and one L dwarf. The remaining four objects include a previously identified T Tauri star, a young star with outbursts, and two objects too faint to confirm. A detailed examination of the 49 flare star light curves revealed an additional six flares on five stars, resulting in a total of 55 flares on 49 objects ranging in V-band contrast from ΔV = −1 to −10.2 mag. Using an empirical flare model to estimate the unobserved portions of the flare light curve, we obtain lower limits on the V-band energy emitted during each flare, spanning log(E_V/erg) = 32–35, which are among the most energetic flares detected on M dwarfs. The ASAS-SN M dwarf flare stars show a higher fraction of Hα emission, as well as stronger Hα emission, compared to M dwarfs selected without reference to activity, consistent with belonging to a population of more magnetically active stars. We also examined the distribution of tangential velocities, finding that the ASAS-SN flaring M dwarfs are likely to be members of the thin disk and are neither particularly young nor old
Experimental discrimination of ion stopping models near the Bragg peak in highly ionized matter
The energy deposition of ions in dense plasmas is a key process in inertial confinement fusion that determines the α-particle heating expected to trigger a burn wave in the hydrogen pellet and resulting in high thermonuclear gain. However, measurements of ion stopping in plasmas are scarce and mostly restricted to high ion velocities where theory agrees with the data. Here, we report experimental data at low projectile velocities near the Bragg peak, where the stopping force reaches its maximum. This parameter range features the largest theoretical uncertainties and conclusive data are missing until today. The precision of our measurements, combined with a reliable knowledge of the plasma parameters, allows to disprove several standard models for the stopping power for beam velocities typically encountered in inertial fusion. On the other hand, our data support theories that include a detailed treatment of strong ion-electron collisions
Triplet lifetime in gaseous argon
MiniCLEAN is a single-phase liquid argon dark matter experiment. During the
initial cooling phase, impurities within the cold gas (140 K) were monitored
by measuring the scintillation light triplet lifetime, and ultimately a triplet
lifetime of 3.480 0.001 (stat.) 0.064 (sys.) s was obtained,
indicating ultra-pure argon. This is the longest argon triplet time constant
ever reported. The effect of quenching of separate components of the
scintillation light is also investigated
- …