181 research outputs found

    Vitamin D Receptor Activation Mitigates the Impact of Uremia on Endothelial Function in the 5/6 Nephrectomized Rats

    Get PDF
    Endothelial dysfunction increases cardiovascular disease risk in chronic kidney disease (CKD). This study investigates whether VDR activation affects endothelial function in CKD. The 5/6 nephrectomized (NX) rats with experimental chronic renal insufficiency were treated with or without paricalcitol, a VDR activator. Thoracic aortic rings were precontracted with phenylephrine and then treated with acetylcholine or sodium nitroprusside. Uremia significantly affected aortic relaxation (−50.0 ± 7.4% in NX rats versus −96.2 ± 5.3% in SHAM at 30 ΌM acetylcholine). The endothelial-dependent relaxation was improved to –58.2 ± 6.0%, –77.5 ± 7.3%, and –90.5 ± 4.0% in NX rats treated with paricalcitol at 0.021, 0.042, and 0.083 Όg/kg for two weeks, respectively, while paricalcitol at 0.042 Όg/kg did not affect blood pressure and heart rate. Parathyroid hormone (PTH) suppression alone did not improve endothelial function since cinacalcet suppressed PTH without affecting endothelial-dependent vasorelaxation. N-omega-nitro-L-arginine methyl ester completely abolished the effect of paricalcitol on improving endothelial function. These results demonstrate that VDR activation improves endothelial function in CKD

    Models and experimental results from the wide aperture Nb-Ti magnets for the LHC upgrade

    Full text link
    MQXC is a Nb-Ti quadrupole designed to meet the accelerator quality requirements needed for the phase-1 LHC upgrade, now superseded by the high luminosity upgrade foreseen in 2021. The 2-m-long model magnet was tested at room temperature and 1.9 K. The technology developed for this magnet is relevant for other magnets currently under development for the high-luminosity upgrade, namely D1 (at KEK) and the large aperture twin quadrupole Q4 (at CEA). In this paper we present MQXC test results, some of the specialized heat extraction features, spot heaters, temperature sensor mounting and voltage tap development for the special open cable insulation. We look at some problem solving with noisy signals, give an overview of electrical testing, look at how we calculate the coil resistance during at quench and show that the heaters are not working We describe the quench signals and its timing, the development of the quench heaters and give an explanation of an Excel quench calculation and its comparison including the good agreement with the MQXC test results. We propose an improvement to the magnet circuit design to reduce voltage to ground values by factor 2. The program is then used to predict quench Hot-Spot and Voltages values for the D1 dipole and the Q4 quadrupole.Comment: 8 pages, Contribution to WAMSDO 2013: Workshop on Accelerator Magnet, Superconductor, Design and Optimization; 15 - 16 Jan 2013, CERN, Geneva, Switzerlan

    Transvenous Lead Extraction in Patients with Cardiac Implantable Device: The Impact of Systemic and Local Infection on Clinical Outcomes. An ESC‐EHRA ELECTRa (European Lead Extraction Controlled) Registry Substudy

    Get PDF
    Background: Infections of cardiac implantable devices (CIEDI) have poor outcomes despite improvement in lead extraction (TLE) procedures. Methods: To explore the influence of CIEDI on the outcomes of TLE and the differences between patients with systemic (Sy) vs. local (Lo) CIEDI, we performed a sub‐analysis of the EORP ELECTRa (European Lead Extraction ConTRolled) Registry. Results: Among 3555 patients enrolled by 73 centers in 19 Countries, the indication for TLE was CIEDI in 1850: 1170 with Lo‐CIEDI and 680 with Sy‐CIEDI. Patients with CIEDI had a worse in‐hospital prognosis in terms of major complications (3.57% vs. 1.71%; p = 0.0007) and mortality (2.27% vs. 0.49%; p < 0.0001). Sy‐CIEDI was an independent predictor of in‐hospital death (H.R. 2.14; 95%CI 1.06–4.33. p = 0.0345). Patients with Sy‐CIEDI more frequently had an initial CIED implant and a higher prevalence of comorbidities, while subjects with Lo‐CIEDI had a higher prevalence of previous CIED procedures. Time from signs of CIEDI and TLE was longer for Lo‐CIEDI despite a shorter pre‐TLE antibiotic treatment. Conclusions: Patients with CIEDI have a worse in‐hospital prognosis after TLE, especially for patients with Sy‐CIEDI. These results raise the suspicion that in a relevant group of patients CIEDI can be systemic from the beginning without progression from Lo‐CIEDI. Future research is needed to characterize this subgroup of patients

    Multicenter Study of High-Dose Daptomycin for Treatment of Enterococcal Infections

    Get PDF
    Enterococci are among the leading pathogens isolated in hospital-acquired infections. Current antimicrobial options for vancomycin-resistant enterococci (VRE) are limited. Prior data suggests that daptomycin \u3e 6mg/kg/day may be used to treat enterococcal infections. We retrospectively evaluated the effectiveness and safety of high-dose daptomycin (HD-daptomycin) therapy (\u3e 6 mg/kg) in a multicenter cohort of adult patients with enterococcal infections to describe the characteristics and outcomes. Two-hundred and forty-five patients were evaluated. Enterococcus faecium was identified in 175 (71%), followed by 49 (20%) Enterococcus faecalis and 21 (9%) Enterococcus spp., overall 204 (83%) were VRE. Enterococcal infections included bacteremia (173, 71%), intra-abdominal (35, 14%) and bone/joint (25, 10%). The median dose and duration of HD-daptomycin was 8.2 mg/kg/day (IQR 7.7-9.7) and 10 days (IQR 6-15), respectively. Overall clinical success rate was 89% (193/218) and microbiological eradication was observed in 93% (177/191) of patients. The median time to clearance of blood cultures on HD-daptomycin was 3 days (IQR 2-5). Thirty-day all cause mortality rate was 27% and 5 (2%) patients developed daptomycin nonsusceptible enterococcal strains while on HD-daptomycin. Seven patients (3%) had creatine phosphokinase (CPK) elevation, yet no HD-daptomycin regimen was discontinued due to an elevated CPK and all patients were asymptomatic. Overall, there was a high frequency of clinical success and microbiological eradication in patients treated with HD-daptomycin for enterococcal infections, even in patients with complicated and difficult to treat infections. No adverse event-related discontinuation of HD-daptomycin was noted. HD-daptomycin may be an option for the treatment of enterococcal infections

    Insertion Magnets

    Full text link
    Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temperature and density. To sustain and extend its discovery potential, the LHC will need a major upgrade in the 2020s. This will increase its luminosity (rate of collisions) by a factor of five beyond the original design value and the integrated luminosity (total collisions created) by a factor ten. The LHC is already a highly complex and exquisitely optimised machine so this upgrade must be carefully conceived and will require about ten years to implement. The new configuration, known as High Luminosity LHC (HL-LHC), will rely on a number of key innovations that push accelerator technology beyond its present limits. Among these are cutting-edge 11-12 tesla superconducting magnets, compact superconducting cavities for beam rotation with ultra-precise phase control, new technology and physical processes for beam collimation and 300 metre-long high-power superconducting links with negligible energy dissipation. The present document describes the technologies and components that will be used to realise the project and is intended to serve as the basis for the detailed engineering design of HL-LHC.Comment: 19 pages, Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Repor

    Simple Nudges for Better Password Creation

    Get PDF
    Recent security breaches have highlighted the consequences of reusing passwords across online accounts. Recent guidance on password policies by the UK government recommend an emphasis on password length over an extended character set for generating secure but memorable passwords without cognitive overload. This paper explores the role of three nudges in creating website-specific passwords: financial incentive (present vs absent), length instruction (long password vs no instruction) and stimulus (picture present vs not present). Mechanical Turk workers were asked to create a password in one of these conditions and the resulting passwords were evaluated based on character length, resistance to automated guessing attacks, and time taken to create the password. We found that users created longer passwords when asked to do so or when given a financial incentive and these longer passwords were harder to guess than passwords created with no instruction. Using a picture nudge to support password creation did not lead to passwords that were either longer or more resistant to attacks but did lead to account-specific passwords

    Key Role of Mfd in the Development of Fluoroquinolone Resistance in Campylobacter jejuni

    Get PDF
    Campylobacter jejuni is a major food-borne pathogen and a common causative agent of human enterocolitis. Fluoroquinolones are a key class of antibiotics prescribed for clinical treatment of enteric infections including campylobacteriosis, but fluoroquinolone-resistant Campylobacter readily emerges under the antibiotic selection pressure. To understand the mechanisms involved in the development of fluoroquinolone-resistant Campylobacter, we compared the gene expression profiles of C. jejuni in the presence and absence of ciprofloxacin using DNA microarray. Our analysis revealed that multiple genes showed significant changes in expression in the presence of a suprainhibitory concentration of ciprofloxacin. Most importantly, ciprofloxacin induced the expression of mfd, which encodes a transcription-repair coupling factor involved in strand-specific DNA repair. Mutation of the mfd gene resulted in an approximately 100-fold reduction in the rate of spontaneous mutation to ciprofloxacin resistance, while overexpression of mfd elevated the mutation frequency. In addition, loss of mfd in C. jejuni significantly reduced the development of fluoroquinolone-resistant Campylobacter in culture media or chickens treated with fluoroquinolones. These findings indicate that Mfd is important for the development of fluoroquinolone resistance in Campylobacter, reveal a previously unrecognized function of Mfd in promoting mutation frequencies, and identify a potential molecular target for reducing the emergence of fluoroquinolone-resistant Campylobacter

    HE-LHC: The High-Energy Large Hadron Collider – Future Circular Collider Conceptual Design Report Volume 4

    Get PDF
    In response to the 2013 Update of the European Strategy for Particle Physics (EPPSU), the Future Circular Collider (FCC) study was launched as a world-wide international collaboration hosted by CERN. The FCC study covered an energy-frontier hadron collider (FCC-hh), a highest-luminosity high-energy lepton collider (FCC-ee), the corresponding 100 km tunnel infrastructure, as well as the physics opportunities of these two colliders, and a high-energy LHC, based on FCC-hh technology. This document constitutes the third volume of the FCC Conceptual Design Report, devoted to the hadron collider FCC-hh. It summarizes the FCC-hh physics discovery opportunities, presents the FCC-hh accelerator design, performance reach, and staged operation plan, discusses the underlying technologies, the civil engineering and technical infrastructure, and also sketches a possible implementation. Combining ingredients from the Large Hadron Collider (LHC), the high-luminosity LHC upgrade and adding novel technologies and approaches, the FCC-hh design aims at significantly extending the energy frontier to 100 TeV. Its unprecedented centre-of-mass collision energy will make the FCC-hh a unique instrument to explore physics beyond the Standard Model, offering great direct sensitivity to new physics and discoveries
    • 

    corecore