1,394 research outputs found
The 10 Tesla muSR instrument: detector solutions
Solutions to the detector system of the High-Field muSR instrument at the
Paul Scherrer Institut (PSI) in Switzerland are presented. The strict technical
requirements are fulfilled through the application of Geiger-mode Avalanche
Photodiodes.Comment: 6 pages, 4 figure
A time-resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode
In this work we attempt to establish the best time resolution attainable with
a scintillation counter consisting of a plastic scintillator read out by a
Geiger-mode Avalanche Photodiode. The measured time resolution is inversely
proportional to the square root of the energy deposited in the scintillator,
and scales to 18ps (sigma) at 1MeV. This result competes with the best ones
reported for photomultiplier tubes.Comment: 8 pages, 8 figure
The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for SR measurements on a continuous-wave beam
We report on the design and commissioning of a new spectrometer for muon-spin
relaxation/rotation studies installed at the Swiss Muon Source (SS) of the
Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially
a new design and replaces the old general-purpose surface-muon instrument (GPS)
which has been for long the workhorse of the SR user facility at PSI. By
making use of muon and positron detectors made of plastic scintillators read
out by silicon photomultipliers (SiPMs), a time resolution of the complete
instrument of about 160 ps (standard deviation) could be achieved. In addition,
the absence of light guides, which are needed in traditionally built SR
instrument to deliver the scintillation light to photomultiplier tubes located
outside magnetic fields applied, allowed us to design a compact instrument with
a detector set covering an increased solid angle compared to the old GPS.Comment: 11 pages, 11 figure
Rotor blade construction for circulation control aircraft
A circulation control aircraft rotor blade having a spanwise Coanda surface 16 and a plurality of spanwise extending flexible composite material panels 18 cooperating with the surface to define slots for the discharge of compressed air from within the blade with each panel having first flexure means 60 associated with screw adjustments 36 for establishing a slot opening preload and second flexure means 62 associated with screw adjustments 38 for establishing a slot maximum opening
Seroprevalence and risk factors of infections with Neospora caninum and Toxoplasma gondii in hunting dogs from Campania region, southern Italy
Hunting dogs have probably a higher level of exposure to Neospora caninum Dubey, Carpenter, Speer, Topper et Uggla, 1988 and Toxoplasma gondii Nicolle et Manceaux, 1908 than other canine populations for their different lifestyle. The aim of our survey was to determine the seroprevalence of N. caninum and T. gondii in hunting dogs from southern Italy and assess risk factors related to these protozoan infections. Blood samples were collected from 398 hunting dogs (19 different breeds, aged from 5 month to 14 years). The sera were screened by indirect fluorescence antibody test; a titre ≥ 50 was considered positive. Antibodies to N. caninum and T. gondii were detected in 59 (15%) dogs with titres from 50 to 3 200 and in 94 (24%) dogs with titres from 50 to 1 600, respectively, with co-infection in 25 (6%) dogs. Statistical difference (p ≤ 0.05) was found only for infection with T. gondii between two age groups: ≥ 2-4 years (16%) and ≥ 4-7 years (33%); other observed characteristics were without statistical significance. Our results suggest that the hunting dogs could play an important role in the transmission cycle of N. caninum between wild animals and livestock. This is the first detection of antibodies to T. gondii in hunting dogs in Italy
Experimental determination of continuous cooling transformation diagram for high strength steel X155CrMoV12
The article is a result of investigations which deals with the phase transformations of tool steel X155CrMoV12. The experimental data obtained was used to evaluate the resulting Continuous Cooling Transform (CCT) diagram, which consists of seven dilation curves. All experimental samples from dilatometric analyzes were then subjected to microstructural analyzes and hardness measurements to characterize the microstructure and hardness for each heat treatment mode tested. Atomic Force Microscopy (AFM) microscopy was also used to study the carbides present in steels and their size and shape for all selected cooling modes
Dilatometric analysis of cooling curves for high strength steel X155CrMoV12
The article deals with phase transformations and austenitizing behavior of the X155CrMoV12 tool steel. Dilatation analyses of a series of samples were performed at various cooling rates, chosen in the range from 10 °C/s to 0,1°C/s. Acquired experimental data were used for evaluation of dilatometric curves in order to map the temperature ranges of phase transformations of the austenite to pearlite, bainite or martensite. All experimental samples from dilatometric analyses were then subjected to microstructural analyses and hardness measurements to characterize the microstructure and hardness for each tested heat treatment regime
A new technique for elucidating -decay schemes which involve daughter nuclei with very low energy excited states
A new technique of elucidating -decay schemes of isotopes with large
density of states at low excitation energies has been developed, in which a
Broad Energy Germanium (BEGe) detector is used in conjunction with coaxial
hyper-pure germanium detectors. The power of this technique has been
demonstrated on the example of 183Hg decay. Mass-separated samples of 183Hg
were produced by a deposition of the low-energy radioactive-ion beam delivered
by the ISOLDE facility at CERN. The excellent energy resolution of the BEGe
detector allowed rays energies to be determined with a precision of a
few tens of electronvolts, which was sufficient for the analysis of the
Rydberg-Ritz combinations in the level scheme. The timestamped structure of the
data was used for unambiguous separation of rays arising from the
decay of 183Hg from those due to the daughter decays
- …