48 research outputs found

    Prevalence of Salmonella Typhi, Staphylococcus aureus and intestinal parasites among male food handlers in Laghouat Province, Algeria

    Get PDF
    Background: Food-borne diseases are a global public health problem, most especially in developing countries. Food handlers with a low level of  personal hygiene may be colonized or infected by a wide range of enteric pathogenic micro-organisms including intestinal parasites and bacteria.  The aim of this study is to determine the prevalence of Salmonella Typhi, Staphylococcus aureus and intestinal parasites among male food handlers  in Laghouat province, southern Algeria. Methodology: In this cross-sectional study, stool samples and fingernail samples of both hands were collected from 155 randomly selected male  food handlers. Stool specimens were examined by direct wet mount, formalinether concentration, xenic invitro culture and staining methods for  parasitological identification. For bacterial isolation, standard culture media including Hektoen agar, Salmonella-Shigella (SS), Mannitol salt, and  Blood agar plates were used. Conventional biochemical tests were used for identification of S. Typhi and S. aureus. Antimicrobial susceptibility test  (AST) was performed for bacterial isolates by the Kirby-Bauer disk diffusion method. Data analysis was done using Minitab version 19 software, and  Pearson’s Chi-square test was used to determine association between categorical variables. P value < 0.05 was considered statistically significant.   Results: The overall prevalence rate of intestinal parasites among the study subjects was 40% (62/155). Blastocystis spp was the most frequent  parasite isolated (16.8%), followed by Giardia intestinalis (8.4%), Entamoeba histolytica/dispar (7.7%), Entamoeba coli (3.2%), Trichomonas intestinalis  (2.6%) and Endolimax nana (1.3%). Stool cultures revealed 4 (2.6%) positive samples for S. Typhi, and S. aureus was isolated from fingernail contents  of 23 (14.8%) subjects. All S. Typhi isolates were sensitive to imipenem and ciprofloxacin while S. aureus isolates show high sensitivity to  pristinamycin. Hand washing with soap, finger nail status and clinical manifestations were significantly associated with intestinal parasitic infections,  while clinical manifestation was the only factor associated with S. aureus infection. Conclusion: The present study indicates a high prevalence of pathogenic micro-organisms among male food handlers which highlight the important role of food handlers in the spread and transmission of foodborne infections, and thus requires more attention

    An improved sliding mode control for reduction of harmonic currents in grid system connected with a wind turbine equipped by a doubly-fed induction generator

    Get PDF
    Introduction. The implementation of renewable energy resources into the electrical grid has increased significantly in recent years. Wind power is one of the existing resources. Presently, power electronics has become an indispensable tool in wind power plants. Problem. However the associated control usually has an impact on increasing the harmonic distortion, especially on the output voltage. Goal. This paper proposes a new sliding mode control strategy, applied on a rotor-side of a doubly-fed induction generator. The main goal is to meet the electrical power requirements, while responding to the power quality issues. Methodology. The wind energy conversion system must be able to not only track the maximum power point of the wind energy, but also to mitigate the harmonic currents caused by the non-linear loads. To achieve this goal, the power converters are driven by the proposed sliding mode control strategy. The corresponding two gains of the sliding surface are well selected using a particle swarm optimization algorithm. The particle swarm optimization algorithm solves a constrained optimization problem whose fitness function is a prior formulated as the sum of two mean square error criterions. The first criterion presents the tracking dynamic of the reference active power while the second one presents the tracking dynamic of the reference reactive power. The novelty lies in the implementation of the particle swarm optimization algorithm in conventional sliding mode control strategy, in which the proposed-improved sliding mode control strategy is developed. The wind energy conversion system control uses the principal of the vector oriented control to decouple the control of the active power from that of the reactive power. Results. The improved sliding mode control strategy is applied to control separately theses powers in the presence of non-linear loads. The energy assessment of this strategy is analysed using the wind energy conversion system model based on SimPower software. Originality. The obtained simulation results confirm the superiority of the proposed-improved sliding mode control strategy in terms of reference tracking dynamics and suppression of harmonic currents.Вступ. Використання відновлюваних джерел енергії в електричній мережі останніми роками значно зросло. Енергія вітру – один із існуючих ресурсів. Нині силова електроніка стала незамінним інструментом вітряних електростанцій. Проблема. Проте, відповідне управління зазвичай має вплив на збільшення гармонійних спотворень, особливо у вихідній напрузі. Мета. У цій статті пропонується нова стратегія управління ковзним режимом, що застосовується на боці ротора асинхронного генератора з подвійним живленням. Основна мета – задовольнити вимоги до електроенергії, вирішуючи відповідні проблеми з якістю електроенергії. Методологія. Система перетворення енергії вітру повинна мати можливість не тільки відстежувати точку максимальної потужності вітру, але й пом'якшувати гармонійні струми, викликані нелінійними навантаженнями. Для досягнення цієї мети силові перетворювачі керуються запропонованою стратегією управління ковзним режимом. Відповідні два коефіцієнти посилення поверхні ковзання добре вибираються з використанням алгоритму оптимізації рою частинок. Алгоритм оптимізації рою частинок вирішує задачу оптимізації з обмеженнями, функція придатності якої заздалегідь сформульована як сума двох критеріїв середньоквадратичної похибки. Перший критерій репрезентує динаміку відстеження еталонної активної потужності, а другий – динаміку відстеження еталонної реактивної потужності. Новизна полягає в реалізації алгоритму оптимізації рою частинок у традиційній стратегії управління ковзним режимом, в якій розроблена запропонована покращена стратегія управління ковзним режимом. Управління системою перетворення енергії вітру використовує принцип векторно-орієнтованого управління, щоб відокремити управління активною потужністю від управління реактивною потужністю. Результати. Удосконалена стратегія управління ковзним режимом застосовується для роздільного управління цими потужностями за наявності нелінійних навантажень. Енергетична оцінка цієї стратегії аналізується за допомогою моделі системи перетворення енергії вітру на основі програмного забезпечення SimPower. Оригінальність. Отримані результати моделювання підтверджують перевагу запропонованої удосконаленої стратегії управління ковзним режимом з точки зору еталонної динаміки стеження та придушення гармонійних струмів

    Fault diagnosis of power converters in a grid connected photovoltaic system using artificial neural networks

    Get PDF
    Introduction. The widespread use of photovoltaic systems in various applications has spotlighted the pressing requirement for reliability, efficiency and continuity of service. The main impediment to a more effective implementation has been the reliability of the power converters. Indeed, the presence of faults in power converters that can cause malfunctions in the photovoltaic system, which can reduce its performance. Novelty. This paper presents a technique for diagnosing open circuit failures in the switches (IGBTs) of power converters (DC-DC converters and three-phase inverters) in a grid-connected photovoltaic system. Purpose. To ensure supply continuity, a fault-diagnosis process is required throughout all phases of energy production, transfer, and conversion. Methods. The diagnostic approach is based on artificial neural networks and the extraction of features corresponding to the open circuit fault of the IGBT switch. This approach is based on the Clarke transformation of the three-phase currents of the inverter output as well as the calculation of the average value of these currents to determine the exact angle of the open circuit fault. Results. This method is able to effectively identify and localize single or multiple open circuit faults of the DC-DC converter IGBT switch or the three-phase inverter IGBT switches.Вступ. Широке використання фотоелектричних систем у різних застосуваннях висунуло на перший план нагальні вимоги до надійності, ефективності та безперервності обслуговування. Основною перешкодою для ефективнішого застосування була надійність силових перетворювачів. Справді, наявність несправностей у силових перетворювачах може спричинити збої в роботі фотоелектричної системи, що може знизити її продуктивність. Новизна. У цій статті представлена методика діагностики обриву кола в перемикачах (IGBT) силових перетворювачів (перетворювачів постійного струму та трифазних інверторів) у фотоелектричній системі, підключеній до мережі. Мета. Для забезпечення безперервності постачання потрібен процес діагностики несправностей на всіх етапах виробництва, передачі та перетворення енергії. Методи. Діагностичний підхід заснований на штучних нейронних мережах та вилучення ознак, що відповідають обриву кола IGBT-перемикача. Цей підхід ґрунтується на перетворенні Кларка трифазних струмів на виході інвертора, а т акож розрахунку середнього значення цих струмів для визначення точного кута обриву кола. Результати. Цей метод дозволяє ефективно ідентифікувати та локалізувати одиночні або множинні несправності розімкнутого кола IGBT-перемикача DC-DC перетворювача або IGBT-перемикача трифазного інвертора

    Fault diagnosis of power converters in a grid connected photovoltaic system using artificial neural networks

    Get PDF
    Introduction. The widespread use of photovoltaic systems in various applications has spotlighted the pressing requirement for reliability, efficiency and continuity of service. The main impediment to a more effective implementation has been the reliability of the power converters. Indeed, the presence of faults in power converters that can cause malfunctions in the photovoltaic system, which can reduce its performance. Novelty. This paper presents a technique for diagnosing open circuit failures in the switches (IGBTs) of power converters (DC-DC converters and three-phase inverters) in a grid-connected photovoltaic system. Purpose. To ensure supply continuity, a fault-diagnosis process is required throughout all phases of energy production, transfer, and conversion. Methods. The diagnostic approach is based on artificial neural networks and the extraction of features corresponding to the open circuit fault of the IGBT switch. This approach is based on the Clarke transformation of the three-phase currents of the inverter output as well as the calculation of the average value of these currents to determine the exact angle of the open circuit fault. Results. This method is able to effectively identify and localize single or multiple open circuit faults of the DC-DC converter IGBT switch or the three-phase inverter IGBT switches

    QSAR studies of 1,2,5-thiadiazole derivatives analogues of aceclidine as potent M1 muscarinic agonists

    No full text
    International audienceIn the present study, Quantitative structure-activity relationship (QSAR) study have been performed on twenty molecules of 1,2,5-thiadiazole derivatives. The compounds studied are the analogues of aceclidine as potent M1 muscarinic agonists. A multiple linear regression (MLR) procedure was used to design the relationships between molecular descriptors and biological activity of the 1,2,5- thiadiazole derivatives. The predictivity of the model was estimated by cross-validation with the leave-one-outmethod. Our results suggest a QSAR model based on the following descriptors Log P , HE, Pol, MR, MV, and MW, SAG, and Etotal. High correlation between experimental and predicted activity values was observed, indicating the validation and the good quality of the established QSAR models. © 2018 American Scientific Publishers

    Ex vivo decontamination of yeast-colonized dentures by iodine–thiocyanate complexes

    No full text
    Sarra Sebaa,1,2 Maxime Faltot,1 Sandra De Breucker,3 Zahia Boucherit-Otmani,2 Françoise Bafort,4 Jean-Paul Perraudin,5 Philippe Courtois1 1Laboratory of Physiology and Pharmacology, Université Libre de Bruxelles, Brussels, Belgium; 2Laboratory of Antibiotics and Antifungals: Physico-Chemistry, Synthesis and Biological Activity, University of Tlemcen, Tlemcen, Algeria; 3Department of Geriatrics, CUB – Hôpital Erasme, Brussels, Belgium; 4Integrated and Urban Plant Pathology Laboratory, Liège University, Gembloux, Belgium; 5Taradon Laboratory, Tubize, Belgium Introduction: Under well-defined experimental conditions, and in the presence of hydrogen peroxide, lactoperoxidase produces stable iodine–thiocyanate complexes that have antimicrobial properties. A novel process was developed to short circuit the consumption of hydrogen peroxide by microbial catalases by producing iodine–thiocyanate complexes prior to contact with microorganisms, with the aim of being able to decontaminate the ex vivo dentures colonized by yeasts. Materials and methods: Teabags containing lactoperoxidase adsorbed on inert clay beads were immersed for 1 minute in phosphate buffer solution (0.1 M pH 7.4) containing 5.2 mM potassium iodide, 1.2 mM potassium thiocyanate, and 5.5 mM hydrogen peroxide. After removing the adsorbed lactoperoxidase, the stability and efficacy of iodine–thiocyanate complexes for Candida-colonized denture decontamination were verified. Investigations were performed in vitro on Candida albicans ATCC 10231 and on clinical isolates from 46 dentures. A Candida plate count was performed after a 24-hour incubation at 37°C on Sabouraud–chloramphenicol or CHROMagar solid media; then, the yeast growth was evaluated in Sabouraud broth by turbidimetry and biofilm biomass by crystal violet staining. Results: In vitro tests demonstrated the effectiveness of the oxidant solution in sterilizing a suspension of 106 Candida cells per milliliter after a 5-minute incubation. A single ex vivo immersion of contaminated dentures in a solution of iodine–thiocyanate complexes led to a decrease of at least 1 log unit in the number of colony-forming units in 58.3% of the tested dentures, while immersing in water alone had no effect on denture colonization (significant X2: p = 0.0006). Conclusion: These data suggest a promising new strategy for decontamination of dentures. Keywords: biofilm, Candida, hygiene, lactoperoxidase, oral cavit
    corecore