25 research outputs found

    Corrosion behaviour of porous Ti intended for biomedical applications

    Get PDF
    Porous Ti implants are being developed inorder to reduce the biomechanical mismatch between theimplant and the bone, as well as increasing the osseointegrationby improving the bone in-growth. Most of the focusin the literature has been on the structural, biological andmechanical characterization of porous Ti whereas there islimited information on the electrochemical characterization.Therefore, the present work aims to study the corrosionbehaviour of porous Ti having 30 and 50 % ofnominal porosity, produced by powder metallurgy routeusing the space holder technique. The percentage, size anddistribution of the pores were determined by image analysis.Electrochemical tests consisting of potentiodynamicpolarization and electrochemical impedance spectroscopywere performed in 9 g/L NaCl solution at body temperature.Electrochemical studies revealed that samples presenteda less stable oxide film at increased porosity, morespecifically, the complex geometry and the interconnectivityof the pores resulted in formation of less protectiveoxide film in the pores.This study was supported by FCT with the reference project UID/EEA/04436/2013, by FEDER funds through the COMPETE 2020 – Programa Operacional Competitividade e Internacionalizac¸a˜o (POCI) with the reference project POCI-01-0145- FEDER-006941, Programa de Acc¸o˜es Universita´rias Integradas LusoFrancesas’ (PAUILF TC-12_14), and The Calouste Gulbenkian Foundation through ‘‘Programa de Mobilidade Acade´mica para Professores’’. The authors would also like to acknowledge Prof. Ana Senos (University of Aveiro) and Prof. Jose´ Carlos Teixeira (University of Minho) for the provision of the characterization facilities.info:eu-repo/semantics/publishedVersio

    Evaluation of the corrosion resistance of AISI 316 stainless steel filters

    No full text
    In this investigation, the corrosion resistance of AISI 316 SS filters prepared with powders in the size ranges 74-44 µm and 210-105 µm and compacted with pressures of 300 MPa and 400 MPa has been evaluated in naturally aerated 0.5 M H2SO4 solution at 25 °C. Weight loss of filters manufactured with compacting pressure of 400 MPa were significantly higher than that of filters compacted at 300 MPa. The filter compacted at 400 MPa had higher carbon and nitrogen contents compared to those compacted at 300 MPa. The former also had chromium rich precipitates and oxides in the grain boundaries. The pores in filters compacted at 400 MPa were smaller than in filters compacted at 300 MPa. Smaller pores favor the formation of concentration cells and consequently, increased crevice corrosion

    Performance of cryogenically treated tungsten carbide tools in milling operations

    No full text
    10.1007/s00170-005-0379-0International Journal of Advanced Manufacturing Technology327-8638-643IJAT
    corecore