86 research outputs found

    CEOs from Orthopaedic Centers Worldwide Meet to Discuss Common Challenges: 2010 Annual Meeting of the International Society of Orthopaedic Centers

    Get PDF
    The International Society of Orthopaedic Centers was formed in 2006 as a think tank that would bring together thought leaders in orthopaedic surgery from major orthopaedic academic centers around the world. The Society’s mission is to share knowledge and strategies, improve patient care, and foster clinical, educational, and scientific collaboration. As the Society’s agendas developed, the members recognized that many of their aims intersected with those of hospital leadership. Thus, CEOs from member centers were invited to join their physician colleagues at the 2010 meeting in Bologna, Italy in order to explore solutions to administrative challenges related to patient care, volume growth, and costs. This paper describes the dialogue that took place at the meeting

    Healing of surgical site after total hip and knee replacements show similar telethermographic patterns

    Get PDF
    BACKGROUND: Isolated reports indicate the efficacy of infrared thermography for monitoring wound healing and septic complications, but no long-term analysis has ever been performed on this, and there are no data on the telethermographic patterns of surgical site healing after uncomplicated total hip prosthesis and after knee prosthesis. MATERIALS AND METHODS: In this prospective, observational, nonrandomized cohort study, two groups with forty consecutive patients each, who were operated on respectively for total hip and for total knee replacements, underwent telethermographic examination of the operated and contralateral joints prior to and at fixed intervals for up to 1\ua0year after uncomplicated surgery. A digital, portable telethermocamera and dedicated software were used for data acquisition and processing. RESULTS: No thermographic difference was observed preoperatively between the affected side and the contralateral side in both groups. After the intervention, a steep increase in the temperature of the operated joint was recorded after total hip replacement and after knee replacement, with a peak mean differential temperature measured three days postoperatively between the operated and unoperated joint of 3.1\ua0\ub1\ua00.8\ub0C after total hip replacement, and 3.4\ua0\ub1\ua00.7\ub0C after total knee replacement. Thereafter, the mean differential temperature declined slowly to 0.7\ua0\ub1\ua01.1\ub0C and to 0.5\ua0\ub1\ua01.3\ub0C at 60\ua0days, and to 0.0\ua0\ub1\ua01.0\ub0C and -0.1\ua0\ub1\ua01.1\ub0C 90\ua0days post-operatively, respectively. No further changes were observed for up to 1\ua0year after surgery. Results were similar when comparing the average telethermographic values of an elliptical area where the main axis corresponded to the surgical wound. CONCLUSIONS: The surgical sites after uncomplicated total hip or total knee replacement show similar telethermographic patterns for up to 1\ua0year from surgery, and can easily be monitored using a portable, digital, telethermocamera

    Mobile laminar air flow screen for additional operating room ventilation: reduction of intraoperative bacterial contamination during total knee arthroplasty

    Get PDF
    Background Surgical site infections are important complications in orthopedic surgery. A mobile laminar air flow (LAF) screen could represent a useful addition to an operating room (OR) with conventional turbulent air ventilation (12.5 air changes/h), as it could decrease the bacterial count near the operating field. The purpose of this study was to evaluate LAF efficacy at reducing bacterial contamination in the surgical area during 34 total knee arthroplasties (TKAs). Materials and methods The additional unit was used in 17 operations; the LAF was positioned beside the operating table between two of the surgeons, with the air flow directed towards the surgical area (wound). The whole team wore conventional OR clothing and the correct hygiene procedures and rituals were used. Bacterial air contamination (CFU/m3) was evaluated in the wound area in 17 operations with the LAF unit and 17 without the LAF unit. Results The LAF unit reduced the mean bacterial count in the wound area from 23.5 CFU/m3 without the LAF to 3.5 CFU/m3 with the LAF (P<0.0001), which is below the suggested limit for anORwith ultraclean laminar ventilation. There were no significant differences in the mean bacterial count in the instrument table area: 28.6 CFU/m3 were recorded with the LAF (N = 6) unit and 30.8 CFU/m3 (N = 6) without the LAF unit (P = 0.631). During six operations with LAF and six without LAF, particle counts were performed and the number of 0.5 lm particles was analyzed. The particle counts decreased significantly when the LAF unit was used (P = 0.003). Conclusion When a mobile LAF unit was added to the standard OR ventilation, bacterial contamination of the wound area significantly decreased to below the accepted level for an ultraclean OR, preventing SSI infections

    Optimization of wear loss in silicon nitride (Si3N4)–hexagonal boron nitride (hBN) composite using DoE–Taguchi method

    Get PDF
    Introduction The contacting surfaces subjected to progressive loss of material known as ‘wear,’ which is unavoidable between contacting surfaces. Similar kind of phenomenon observed in the human body in various joints where sliding/rolling contact takes place in contacting parts, leading to loss of material. This is a serious issue related to replaced joint or artificial joint. Case description Out of the various material combinations proposed for artificial joint or joint replacement Si3N4 against Al2O3 is one of in ceramic on ceramic category. Minimizing the wear loss of Si3N4 is a prime requirement to avoid aseptic loosening of artificial joint and extending life of joint. Discussion and evaluation In this paper, an attempt has been made to investigate the wear loss behavior of Si3N4–hBN composite and evaluate the effect of hBN addition in Si3N4 to minimize the wear loss. DoE–Taguchi technique is used to plan and analyze experiments. Conclusion Analysis of experimental results proposes 15 N load and 8 % of hBN addition in Si3N4 is optimum to minimize wear loss against alumina

    Minimally Invasive Surgical Approaches and Traditional Total Hip Arthroplasty: A Meta-Analysis of Radiological and Complications Outcomes

    Get PDF
    BACKGROUND: Minimally invasive total hip arthroplasty (MITHA) remains considerably controversial. Limited visibility and prosthesis malposition increase the risk of post-surgical complications compared to those of the traditional method. METHODS: A meta-analysis was undertaken of all published databases up to May 2011. The studies were divided into four subgroups according to the surgical approach taken. The radiological outcomes and complications of minimally invasive surgery were compared to traditional total hip arthroplasty (TTHA) using risk ratio, mean difference, and standardized mean difference statistics. RESULTS: In five studies involving the posterolateral approach, no significant differences were found between the MITHA groups and the TTHA groups in the acetabular cup abduction angle (p = 0.41), acetabular anteversion (p = 0.96), and femoral prosthesis position (p = 0.83). However, the femoral offset was significantly increased (WMD = 3.00; 95% CI, 0.40-5.60; p = 0.02). Additionally, there were no significant differences among the complications in both the groups (dislocations, nerve injury, infection, deep vein thrombosis, proximal femoral fracture) and revision rate (p>0.05). In three studies involving the posterior approach, there were no significant differences in radiological outcomes or all other complications between MITHA or TTHA groups (p>0.05). Three studies involved anterolateral approach, while 2 studies used the lateral approach. However, the information from imaging and complications was not adequate for statistical analysis. CONCLUSIONS: Posterior MITHA seems to be a safe surgical procedure, without the increased risk of post-operative complication rates and component malposition rates. The posterolateral approach THA may lead to increased femoral offset. The current data are not enough to reach a positive conclusion that lateral and anterolateral approaches will result in increased risks of adverse effects and complications at the prosthesis site
    corecore