1,721 research outputs found
Global Environmental Change: What Can Health Care Providers and the Environmental Health Community Do About It Now?
The debate about whether global environmental change is real is now over; in its wake is the realization that it is happening more rapidly than predicted. These changes constitute a profound challenge to human health, both as a direct threat and as a promoter of other risks. We call on health care providers to inform themselves about these issues and to become agents of change in their communities. It is our responsibility as clinicians to educate patients and their communities on the connections between regressive policies, unsustainable behaviors, global environmental changes, and threats to health and security. We call on professional organizations to assist in educating their members about these issues, in helping clinicians practice behavior change with their patients, and in adding their voices to this issue in our statehouses and Congress. We call for the development of carbon- and other environmental-labeling of consumer products so individuals can make informed choices; we also call for the rapid implementation of policies that provide tangible economic incentives for choosing environmentally sustainable products and services. We urge the environmental health community to take up the challenge of developing a global environmental health index that will incorporate human health into available âplanetary healthâ metrics and that can be used as a policy tool to evaluate the impact of interventions and document spatial and temporal shifts in the healthfulness of local areas. Finally, we urge our political, business, public health, and academic leaders to heed these environmental warnings and quickly develop regulatory and policy solutions so that the health of populations and the integrity of their environments will be ensured for future generations
Interaction of Stress, Lead Burden, and Age on Cognition in Older Men: The VA Normative Aging Study
BACKGROUND. Low-level exposure to lead and to chronic stress may independently influence cognition. However, the modifying potential of psychosocial stress on the neurotoxicity of lead and their combined relationship to aging-associated decline have not been fully examined. OBJECTIVES. We examined the cross-sectional interaction between stress and lead exposure on Mini-Mental State Examination (MMSE) scores among 811 participants in the Normative Aging Study, a cohort of older U.S. men. METHODS. We used two self-reported measures of stress appraisal-a self-report of stress related to their most severe problem and the Perceived Stress Scale (PSS). Indices of lead exposure were blood lead and bone (tibia and patella) lead. RESULTS. Participants with higher self-reported stress had lower MMSE scores, which were adjusted for age, education, computer experience, English as a first language, smoking, and alcohol intake. In multivariable-adjusted tests for interaction, those with higher PSS scores had a 0.57-point lower (95% confidence interval, -0.90 to 0.24) MMSE score for a 2-fold increase in blood lead than did those with lower PSS scores. In addition, the combination of high PSS scores and high blood lead categories on one or both was associated with a 0.05-0.08 reduction on the MMSE for each year of age compared with those with low PSS score and blood lead level (p < 0.05). CONCLUSIONS. Psychological stress had an independent inverse association with cognition and also modified the relationship between lead exposure and cognitive performance among older men. Furthermore, high stress and lead together modified the association between age and cognition.National Institutes of Health (R01ES07821, R01HL080674, R01HL080674-02S1, R01ES013744, ES05257-06A1, P20MD000501, P42ES05947, ES03918-02); National Center for Research Resources General Clinical Research Center (M01RR02635); Leaves of Grass Foundation; United States Department of Veterans Affair
Recommended from our members
Maternal arsenic exposure and impaired glucose tolerance during pregnancy
Background: Accumulating evidence has shown an increased risk of type 2 diabetes in general populations exposed to arsenic, but little is known about exposures during pregnancy and the association with gestational diabetes (GD). Objectives: We studied 532 women living proximate to the Tar Creek Superfund Site to investigate whether arsenic exposure is associated with impaired glucose tolerance during pregnancy. Methods: Blood glucose was measured between 24 and 28 weeks gestation after a 1-hr oral glucose tolerance test (GTT) as part of routine prenatal care. Blood and hair were collected at delivery and analyzed for arsenic using inductively coupled plasma mass spectrometry with dynamic reaction cell. Results: Arsenic concentrations ranged from 0.2 to 24.1 ÎŒg/L (ppb) (mean ± SD, 1.7 ±1.5) and 1.1 to 724.4 ng/g (ppb) (mean ± SD, 27.4 ± 61.6) in blood and hair, respectively. One-hour glucose levels ranged from 40 to 284 mg/dL (mean ± SD, 108.7 ± 29.5); impaired glucose tolerance was observed in 11.9% of women when using standard screening criterion (> 140 mg/dL). Adjusting for age, Native-American race, prepregnancy body mass index, Medicaid use, and marital status, women in the highest quartile of blood arsenic exposure had 2.8 higher odds of impaired GTT than women in the lowest quartile of exposure (95% confidence interval, 1.1â6.9) (p-trend = 0.008). Conclusions: Among this population of pregnant women, arsenic exposure was associated with increased risk of impaired GTT at 24â28 weeks gestation and therefore may be associated with increased risk of GD
Detection of skewed X-chromosome inactivation in Fragile X syndrome and X chromosome aneuploidy using quantitative melt analysis.
Methylation of the fragile X mental retardation 1 (FMR1) exon 1/intron 1 boundary positioned fragile X related epigenetic element 2 (FREE2), reveals skewed X-chromosome inactivation (XCI) in fragile X syndrome full mutation (FM: CGGÂ >Â 200) females. XCI skewing has been also linked to abnormal X-linked gene expression with the broader clinical impact for sex chromosome aneuploidies (SCAs). In this study, 10 FREE2 CpG sites were targeted using methylation specific quantitative melt analysis (MS-QMA), including 3 sites that could not be analysed with previously used EpiTYPER system. The method was applied for detection of skewed XCI in FM females and in different types of SCA. We tested venous blood and saliva DNA collected from 107 controls (CGGÂ <Â 40), and 148 FM and 90 SCA individuals. MS-QMA identified: (i) most SCAs if combined with a Y chromosome test; (ii) locus-specific XCI skewing towards the hypomethylated state in FM females; and (iii) skewed XCI towards the hypermethylated state in SCA with 3 or more X chromosomes, and in 5% of the 47,XXY individuals. MS-QMA output also showed significant correlation with the EpiTYPER reference method in FM males and females (PÂ <Â 0.0001) and SCAs (PÂ <Â 0.05). In conclusion, we demonstrate use of MS-QMA to quantify skewed XCI in two applications with diagnostic utility
A new bond fluctuation method for a polymer undergoing gel electrophoresis
We present a new computational methodology for the investigation of gel
electrophoresis of polyelectrolytes. We have developed the method initially to
incorporate sliding motion of tight parts of a polymer pulled by an electric
field into the bond fluctuation method (BFM). Such motion due to tensile force
over distances much larger than the persistent length is realized by non-local
movement of a slack monomer at an either end of the tight part. The latter
movement is introduced stochastically. This new BFM overcomes the well-known
difficulty in the conventional BFM that polymers are trapped by gel fibers in
relatively large fields. At the same time it also reproduces properly
equilibrium properties of a polymer in a vanishing filed limit. The new BFM
thus turns out an efficient computational method to study gel electrophoresis
in a wide range of the electric field strength.Comment: 15 pages, 11 figure
Iron Metabolism Genes, Low-Level Lead Exposure, and QT Interval
Background: Cumulative exposure to lead has been shown to be associated with depression of electrocardiographic conduction, such as QT interval (time from start of the Q wave to end of the T wave). Because iron can enhance the oxidative effects of lead, we examined whether polymorphisms in iron metabolism genes [hemochromatosis (), transferrin () C2, and heme oxygenase-1 ()] increase susceptibility to the effects of lead on QT interval in 613 community-dwelling older men. Methods: We used standard 12-lead electrocardiograms, K-shell X-ray fluorescence, and graphite furnace atomic absorption spectrometry to measure QT interval, bone lead, and blood lead levels, respectively. Results: A one-interquartile-range increase in tibia lead level (13 ÎŒg/g) was associated with a 11.35-msec [95% confidence interval (CI), 4.05â18.65 msec] and a 6.81-msec (95% CI, 1.67â11.95 msec) increase in the heart-rateâcorrected QT interval among persons carrying long alleles and at least one copy of an variant, respectively, but had no effect in persons with short and middle alleles and the wild-type HFE genotype. The lengthening of the heart-rateâcorrected QT interval with higher tibia lead and blood lead became more pronounced as the total number (0 vs. 1 vs. â„2) of gene variants increased (tibia, -trend = 0.01; blood, -trend = 0.04). This synergy seems to be driven by a joint effect between variant and L alleles. Conclusion: We found evidence that gene variants related to iron metabolism increase the impacts of low-level lead exposure on the prolonged QT interval. This is the first such report, so these results should be interpreted cautiously and need to be independently verified
Effect of Breast Milk Lead on Infant Blood Lead Levels at 1 Month of Age
Nursing infants may be exposed to lead from breast milk, but relatively few data exist with which to evaluate and quantify this relationship. This route of exposure constitutes a potential infant hazard from mothers with current ongoing exposure to lead as well as from mothers who have been exposed previously due to the redistribution of cumulative maternal bone lead stores. We studied the relationship between maternal breast milk lead and infant blood lead levels among 255 motherâinfant pairs exclusively or partially breast-feeding through 1 month of age in Mexico City. A rigorous, well-validated technique was used to collect, prepare, and analyze the samples of breast milk to minimize the potential for environmental contamination and maximize the percent recovery of lead. Umbilical cord and maternal blood lead were measured at delivery; 1 month after delivery (± 5 days) maternal blood, bone, and breast milk and infant blood lead levels were obtained. Levels of lead at 1 month postpartum were, for breast milk, 0.3â8.0 ÎŒg/L (mean ± SD, 1.5 ± 1.2); maternal blood lead, 2.9â29.9 ÎŒg/dL (mean ± SD, 9.4 ± 4.5); and infant blood lead, 1.0â23.1 ÎŒg/dL (mean ± SD, 5.5 ± 3.0). Infant blood lead at 1 month postpartum was significantly correlated with umbilical cord (Spearman correlation coefficient r(S) = 0.40, p < 0.0001) and maternal (r(S) = 0.42, p < 0.0001) blood lead at delivery and with maternal blood (r(S) = 0.67, p < 0.0001), patella (r(S) = 0.19, p = 0.004), and breast milk (r(S) = 0.32, p < 0.0001) lead at 1 month postpartum. Adjusting for cord blood lead, infant weight change, and reported breast-feeding status, a difference of approximately 2 ÎŒg/L (ppb; from the midpoint of the lowest quartile to the midpoint of the highest quartile) breast milk lead was associated with a 0.82 ÎŒg/dL increase in blood lead for breast-feeding infants at 1 month of age. Breast milk lead accounted for 12% of the variance of infant blood lead levels, whereas maternal blood lead accounted for 30%. Although these levels of lead in breast milk were low, they clearly have a strong influence on infant blood lead levels over and above the influence of maternal blood lead. Additional information on the lead content of dietary alternatives and interactions with other nutritional factors should be considered. However, because human milk is the best and most complete nutritional source for young infants, breast-feeding should be encouraged because the absolute values of the effects are small within this range of lead concentrations
- âŠ