119 research outputs found
Automated analysis of digital fundus autofluorescence images of geographic atrophy in advanced age-related macular degeneration using confocal scanning laser ophthalmoscopy (cSLO)
BACKGROUND: Fundus autofluorescence (AF) imaging using confocal scanning laser ophthalmoscopy (cSLO) provides an accurate delineation of areas of geographic atrophy (GA). Automated computer-assisted methods for detecting and removing interfering vessels are needed to support the GA quantification process in longitudinal studies and in reading centres. METHODS: A test tool was implemented that uses region-growing techniques to segment GA areas. An algorithm for illuminating shadows can be used to process low-quality images. Agreement between observers and between three different methods was evaluated by two independent readers in a pilot study. Agreement and objectivity were assessed using the Bland-Altman approach. RESULTS: The new method (C) identifies vascular structures that interfere with the delineation of GA. Results are comparable to those of two commonly used procedures (A, B), with a mean difference between C and A of -0.67 mm(2 )(95% CI [-0.99, -0.36]), between B and A of -0.81 mm(2), (95% CI [-1.08, -0.53]), and between C and B of 0.15 mm(2 )(95% CI [-0.12, 0.41]). Objectivity of a method is quantified by the mean difference between observers: A 0.30 mm(2 )(95% CI [0.02, 0.57]), B -0.11 mm(2 )(95% CI [-0.28, 0.10]), and C 0.12 mm(2 )(95% CI [0.02, 0.22]). CONCLUSION: The novel procedure is comparable with regard to objectivity and inter-reader agreement to established methods of quantifying GA. It considerably speeds up the lengthy measurement process in AF with well defined GA zones
Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report
This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability
Recommended from our members
Relative ellipsoid zone reflectivity and its association with disease severity in age-related macular degeneration: a MACUSTAR study report
Quantification of the relative ellipsoid zone reflectivity (rEZR) might be a structural surrogate parameter for an early disease progression in the context of age-related macular degeneration (AMD). Within the European multicenter, cross-sectional MACUSTAR study, we have devised an automatic approach to determine the mean rEZR [arbitrary units, AU] at two independent visits in SD-OCT volume scans in study participants. Linear mixed-effects models were applied to analyze the association of AMD stage and AMD associated high-risk features including presence of pigmentary abnormalities, reticular pseudodrusen (RPD), volume of the retinal-pigment-epithelial-drusenoid-complex (RPEDC) with the rEZR. Intra-class correlation coefficients (ICC) were determined for rEZR reliability analysis. Within the overall study cohort (301 participants), we could observe decreased rEZR values (coefficient estimate ± standard error) of - 8.05 ± 2.44 AU (p = 0.0011) in the intermediate and of - 22.35 ± 3.28 AU (p < 0.0001) in the late AMD group. RPD presence was significantly associated with the rEZR in iAMD eyes (- 6.49 ± 3.14 AU; p = 0.0403), while there was a good ICC of 0.846 (95% confidence interval: 0.809; 0.876) in the overall study cohort. This study showed an association of rEZR with increasing disease severity and the presence of iAMD high-risk features. Further studies are necessary to evaluate the rEZR's value as a novel biomarker for AMD and disease progression
Recommended from our members
Clinical study protocol for a low-interventional study in intermediate age-related macular degeneration developing novel clinical endpoints for interventional clinical trials with a regulatory and patient access intention-MACUSTAR.
BACKGROUND: There is an unmet need for treatment options in intermediate age-related macular degeneration (iAMD). However, for any new interventions to be tested in clinical trials, novel currently unavailable clinical endpoints need to be developed. Thus, the MACUSTAR study aims to develop and evaluate functional, structural, and patient-reported candidate endpoints for use in future iAMD trials.
METHODS: The protocol describes a low-interventional clinical multicenter study employing a novel two-part design. The cross-sectional part (total duration, 1 month) and the longitudinal part (total duration, 36 months) include participants with iAMD and control groups with early/late/no AMD. The cross-sectional part's primary objective is a technical evaluation of functional, structural, and patient-reported candidate outcomes. The longitudinal part's primary objective is to assess the prognostic power of changes in functional, structural, and patient-reported outcomes for progression from iAMD to late AMD. All data will be used to support a biomarker qualification procedure by regulatory authorities.
DISCUSSION: The MACUSTAR study characterizes and evaluates much needed novel functional, structural, and patient-reported endpoints for future clinical trials in iAMD and will improve our understanding of the natural history and prognostic markers of this condition. TRIAL REGISTRATION: ClinicalTrials.gov NCT03349801 . Registered on 22 November 2017
Recommended from our members
MACUSTAR: Development and Clinical Validation of Functional, Structural, and Patient-Reported Endpoints in Intermediate Age-Related Macular Degeneration
Purpose: Currently, no outcome measures are clinically validated and accepted as clinical endpoints by regulatory agencies for drug development in intermediate age-related macular degeneration (iAMD). The MACUSTAR Consortium, a public-private research group funded by the European Innovative Medicines Initiative intends to close this gap.
Procedures: Development of study protocol and statistical analysis plan including predictive modelling of multimodal endpoints based on a review of the literature and expert consensus.
Results: This observational study consists of a cross-sectional and a longitudinal part. Functional outcome measures assessed under low contrast and low luminance have the potential to detect progression of visual deficit within iAMD and to late AMD. Structural outcome measures will be multimodal and investigate topographical relationships with function. Current patient-reported outcome measures (PROMs) are not acceptable to regulators and may not capture the functional deficit specific to iAMD with needed precision, justifying development of novel PROMs for iAMD. The total sample size will be n = 750, consisting mainly of subjects with iAMD (n = 600).
Conclusions: As clinical endpoints currently accepted by regulators cannot detect functional loss or patient-relevant impact in iAMD, we will clinically validate novel candidate endpoints for iAMD
Development and validation of novel clinical endpoints in intermediate age-related macular degeneration in MACUSTAR
Background
Currently, no validated clinical endpoints for treatment studies exist for intermediate age-related macular degeneration (iAMD).
Objective
The European MACUSTAR study aims to develop and clinically validate adequate clinical endpoints for future treatment studies in iAMD and to identify early determinants of disease progression to late stage AMD.
Material and methods
The MACUSTAR study protocol was developed by an international consortium of researchers from academia, the pharmaceutical industry and medical device companies. The MACUSTAR project is funded by the Innovative Medicines Initiative 2 (IMI2) of the European Union.
Results
The MACUSTAR study consists of a cross-sectional and a longitudinal investigation. A total of 750 subjects with early, intermediate and late AMD as well as control subjects with no signs of AMD will be included with a follow-up period of 3 years. Overall, 20 European study centers are involved.
Conclusion
The MACUSTAR project will generate large high-quality datasets, which will allow clinical validation of novel endpoints for future interventional trials in iAMD. The aim is that these endpoints will be accepted as suitable for medication approval studies by the regulatory authorities and that understanding of the disease process will be improved
Recommended from our members
Use of composite endpoints in early and intermediate age-related macular degeneration clinical trials - state-of-the-art and future directions
The slow progression of early AMD stages to advanced AMD requires the use of surrogate endpoints in clinical trials. The use of combined endpoints may allow for shorter and smaller trials due to increased precision. We performed a literature search for the use of composite endpoints as primary outcome measures in clinical studies of early AMD stages. PubMed was searched for composite endpoints used in early/intermediate AMD studies published during the last 10 years. A total of 673 articles of interest were identified. After reviewing abstracts and applicable full-text articles, 33 articles were eligible and thus included in the qualitative synthesis. The main composite endpoint categories were: Combined structural and functional endpoints, combined structural endpoints, combined functional endpoints and combined multi-categorical endpoints. The majority of the studies included binary composite endpoints. There was a lack of sensitivity analyses of different endpoints against accepted outcomes (i.e. progression) in the literature. Various composite outcome measures have been used but there is a lack of standardization. To date no agreement on the optimal approach to implement combined endpoints in clinical studies of early stages of AMD exists and no surrogate endpoints have been accepted for AMD progression
Recommended from our members
Comparison of visual function in structurally defined sub-phenotypes of intermediate AMD: A MACUSTAR study report
Recommended from our members
Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991-0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757-0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD
- …