10 research outputs found

    The commissioning of the CUORE experiment: the mini-tower run

    Get PDF
    CUORE is a ton-scale experiment approaching the data taking phase in Gran Sasso National Laboratory. Its primary goal is to search for the neutrinoless double-beta decay in 130Te using 988 crystals of tellurim dioxide. The crystals are operated as bolometers at about 10 mK taking advantage of one of the largest dilution cryostat ever built. Concluded in March 2016, the cryostat commissioning consisted in a sequence of cool down runs each one integrating new parts of the apparatus. The last run was performed with the fully configured cryostat and the thermal load at 4 K reached the impressive mass of about 14 tons. During that run the base temperature of 6.3 mK was reached and maintained for more than 70 days. An array of 8 crystals, called mini-tower, was used to check bolometers operation, readout electronics and DAQ. Results will be presented in terms of cooling power, electronic noise, energy resolution and preliminary background measurements

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    CUORE: first results and prospects

    No full text
    International audienceCUORE is the first bolometric tonne-scale experiment aiming at the investigation of neutrinoless double-beta (0ν\nu2β\beta) decay of 130^{130}Te. The cryogenic commissioning followed by the detector installation and cool down took place during 2016. After the optimisation of all the detectors, the data-taking started in spring 2017. We report about the results of the first dataset acquired in May, which led to a limit on the 0ν\nu2β\beta half-life of 130^{130}Te of 6.6×\times1024^{24} yr. An upgrade of CUORE, named CUPID, is planned to improve the 0ν\nu2β\beta-decay sensitivity via passive and active background reduction and crystal enrichment. Some technologies for CUPID are currently under study and two of them are presented here, involving the detection of Cherenkov and scintillation light emitted by enriched 130^{130}TeO2_2 and Li2100^{100}_2MoO4_4 crystals respectively. This will allow us to reject the currently dominant a background

    Scapula fractures: interobserver reliability of classification and treatment

    Full text link
    OBJECTIVES:There is substantial variation in the classification and the management of scapula fractures. The first purpose of this study was to analyze the interobserver reliability of the OTA/AO and the New International Classification of scapula fractures. The second purpose was to assess the proportion of agreement among orthopaedic surgeons on operative or nonoperative treatment. DESIGN:: Web-based reliability study SETTING:: Independent orthopaedic surgeons from several countries were invited to classify scapular fractures in an online survey. PARTICIPANTS:One-hundred and three orthopaedic surgeons evaluated 35 movies of 3DCT-reconstruction of selected scapular fractures, representing a full spectrum of fracture patterns. MAIN OUTCOME MEASUREMENTS:Fleiss' kappa (κ) was used to assess the reliability of agreement between the surgeons. RESULTS:: The overall agreement on the OTA/AO Classification was moderate for the types (A, B, and C, κ = 0.54) with a 71% proportion of rater agreement (PA) as well as for the nine groups (A1 to C3, κ = 0.47) with a 57% PA. For the New International Classification, the agreement about the intra-articular extension of the fracture (Fossa (F), κ = 0.79) was substantial, the agreement about a fractured body (Body (B), κ = 0.57) or process was moderate (Process (P), κ = 0.53), however PAs were more than 81%. The agreement on the treatment recommendation was moderate (κ = 0.57) with a 73% PA. CONCLUSIONS:The New International Classification was more reliable. Body and process fractures generated more disagreement than intra-articular fractures and need further clear definitions

    Nutzenbewertung von Trainingsinterventionen für die Sturzprophylaxe bei älteren Menschen - eine systematische Übersicht auf der Grundlage systematischer Übersichten

    No full text

    Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function : Results From the FAITH Trial

    No full text

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar

    Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures

    No full text

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    corecore