113 research outputs found
Functional imaging of plants: A nuclear magnetic resonance study of a cucumber plant
Functional magnetic resonance imaging was used to study transients of biophysical parameters in a cucumber plant in response to environmental changes. Detailed flow imaging experiments showed the location of xylem and phloem in the stem and the response of the following flow characteristics to the imposed environmental changes: the total amount of water, the amount of stationary and flowing water, the linear velocity of the flowing water, and the volume flow. The total measured volume flow through the plant stem was in good agreement with the independently measured water uptake by the roots. A separate analysis of the flow characteristics for two vascular bundles revealed that changes in volume flow of the xylem sap were accounted for by a change in linear-flow velocities in the xylem vessels. Multiple-spin echo experiments revealed two water fractions for different tissues in the plant stem; the spin-spin relaxation time of the larger fraction of parenchyma tissue in the center of the stem and the vascular tissue was down by 17% in the period after cooling the roots of the plant. This could point to an increased water permeability of the tonoplast membrane of the observed cells in this period of quick recovery from severe water los
Imaging Hyperpolarized Pyruvate and Lactate after Blood-Brain Barrier Disruption with Focused Ultrasound
Item does not contain fulltex
Recommended from our members
An 8-channel receive array for improved 31 P MRSI of the whole brain at 3T.
PURPOSE: To demonstrate a 1 H/31 P whole human brain volume coil configuration for 3 Tesla with separate 31 P transmit and receive components that maintains 1 H MRS performance and delivers optimal 31 P MRSI with 1 H decoupling. METHODS: We developed an 8-channel 31 P receive array coil covering the head to be used as an insert for a commercial double-tuned 1 H/31 P birdcage transmit-receive coil. This retains the possibility of using low-power rectangular pulses for 1 H-decoupled 3D 31 P MRSI (nominal resolution 17.6 cm3 ; acquisition duration 13 min) but increases the SNR with the receive sensitivity of 31 P surface coils. The performance of the combined coil setup was evaluated by measuring 1 H and 31 P SNR with and without the 31 P receive array and by assessing the effect of the receive array on the transmit efficiencies of the birdcage coil. RESULTS: Compared to the birdcage coil alone, the 31 P insert in combination with the birdcage achieved an average 31 P SNR gain of 1.4 ± 0.4 in a center partition of the brain. The insert did not cause losses in 1 H MRS performance and transmit efficiency, whereas for 31 P approximately 20% more power was needed to achieve the same γB1. CONCLUSION: The new coil configuration allows 1 H MRSI and optimal 1 H-decoupled 3D 31 P MRSI, with increased SNR of the human brain without patient repositioning, for clinical and research purposes at 3 Tesla.C. Rodgers is funded by the Wellcome Trust and the Royal Society (Grant Number 098436/Z/12/Z)
MRI of intact plants
Nuclear magnetic resonance imaging (MRI) is a non-destructive and non-invasive technique that can be used to acquire two- or even three-dimensional images of intact plants. The information within the images can be manipulated and used to study the dynamics of plant water relations and water transport in the stem, e.g., as a function of environmental (stress) conditions. Non-spatially resolved portable NMR is becoming available to study leaf water content and distribution of water in different (sub-cellular) compartments. These parameters directly relate to stomatal water conductance, CO2 uptake, and photosynthesis. MRI applied on plants is not a straight forward extension of the methods discussed for (bio)medical MRI. This educational review explains the basic physical principles of plant MRI, with a focus on the spatial resolution, factors that determine the spatial resolution, and its unique information for applications in plant water relations that directly relate to plant photosynthetic activity
In vivo clearance of 19F MRI imaging nanocarriers is strongly influenced by nanoparticle ultrastructure
Perfluorocarbons hold great promise both as imaging agents, particularly for (19)F MRI, and in therapy, such as oxygen delivery. (19)F MRI is unique in its ability to unambiguously track and quantify a tracer while maintaining anatomic context, and without the use of ionizing radiation. This is particularly well-suited for inflammation imaging and quantitative cell tracking. However, perfluorocarbons, which are best suited for imaging - like perfluoro-15-crown-5 ether (PFCE) - tend to have extremely long biological retention. Here, we showed that the use of a multi-core PLGA nanoparticle entrapping PFCE allows for a 15-fold reduction of half-life in vivo compared to what is reported in literature. This unexpected rapid decrease in (19)F signal was observed in liver, spleen and within the infarcted region after myocardial infarction and was confirmed by whole body NMR spectroscopy. We demonstrate that the fast clearance is due to disassembly of the ~200 nm nanoparticle into ~30 nm domains that remain soluble and are cleared quickly. We show here that the nanoparticle ultrastructure has a direct impact on in vivo clearance of its cargo i.e. allowing fast release of PFCE, and therefore also bringing the possibility of multifunctional nanoparticle-based imaging to translational imaging, therapy and diagnostics
Quantitative permeability imaging of plant tissues
A method for mapping tissue permeability based on time-dependent diffusion measurements is presented. A pulsed field gradient sequence to measure the diffusion encoding time dependence of the diffusion coefficients based on the detection of stimulated spin echoes to enable long diffusion times is combined with a turbo spin echo sequence for fast NMR imaging (MRI). A fitting function is suggested to describe the time dependence of the apparent diffusion constant in porous (bio-)materials, even if the time range of the apparent diffusion coefficient is limited due to relaxation of the magnetization. The method is demonstrated by characterizing anisotropic cell dimensions and permeability on a subpixel level of different tissues of a carrot (Daucus carota) taproot in the radial and axial directions
Outpatient follow-up after mild traumatic brain injury:Results of the UPFRONT-study
Objective: To investigate outpatient follow-up after mild traumatic brain injury (mTBI) by various medical specialists, for both hospitalized and non-hospitalized patients, and to study guideline adherence regarding hospital admission. Methods: Patients (n = 1151) with mTBI recruited from the emergency department received questionnaires 2 weeks (n = 879), 3 months (n = 780) and 6 months (n = 668) after injury comprising outpatient follow-up by various health care providers, and outcome defined by the Glasgow Outcome Scale Extended (GOS-E) after 6 months. Results: Hospitalized patients (60%) were older (46.6 ± 19.9 vs. 40.6 ± 18.5 years), more severely injured (GCS <15, 50% vs. 13%) with more Computed Tomography (CT) abnormalities on admission (21% vs. 2%) compared to non-hospitalized patients (p < 0.01) . Almost half of the patients visited a neurologist at the outpatient clinic within six months (60% of the hospitalized and 25% of the non-hospitalized patients (χ2 = 67.10, p < 0.01)), and approximately ten per cent consulted a psychiatrist/psychologist. Outcome was unfavourable (GOS-E <7) in 34% of hospitalized and 21% of non-hospitalized patients (χ2 = 11.89, p < 0.01). Conclusion: Two-thirds of all mTBI patients consult one or more specialists within six months after injury, with 30% having an unfavourable outcome. A quarter of non-hospitalized patients was seen at the outpatient neurology clinic, underling the importance of regular follow-up of mTBI patients irrespective of hospital admittance
Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies
Item does not contain fulltextOBJECTIVES: To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. METHODS: A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. RESULTS: The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. CONCLUSIONS: Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures.01 februari 201
- …