47 research outputs found

    Constraints on the injection energy of positrons in the Galactic centre region

    Get PDF
    Recent observations of the 511 keV positron-electron annihilation line in the Galactic centre region by the INTEGRAL/SPI spectrometer have stirred up new speculations about the origin of the large corresponding positron injection rate. Beyond astrophysical candidates, new mechanisms have been put forward. We focus on the annihilation of light dark matter particles and review the various gamma-ray radiation components related to such a source of mono-energetic positrons in addition to the 511 keV line itself. We study the influence of the degree of ionisation of the bulge on this radiation, and its possible effects on the observational constraints on the mass of the hypothetical light dark matter particle or the injection energy of a mono-energetic source of positrons in general.Comment: 4 pages, 7 figures, 1 table. Accepted for publication in the proceedings of the 6th INTEGRAL Workshop on the Obscured Universe (ESA SP-622). 2-8 July 2006, Moscow, Russi

    Soft gamma-ray galactic ridge emission as unveiled by SPI aboard INTEGRAL

    Get PDF
    The origin of the soft gamma-ray (200 keV - 1 MeV) galactic ridge emission is one of the long-standing mysteries in the field of high-energy astrophysics. Population studies at lower energies have shown that emission from accreting compact objects gradually recedes in this domain, leaving place to another source of gamma-ray emission that is characterised by a hard power-law spectrum extending from 100 keV up to 100 MeV The nature of this hard component has remained so far elusive, partly due to the lack of sufficiently sensitive imaging telescopes that would be able to unveil the spatial distribution of the emission. The SPI telescope aboard INTEGRAL allows now for the first time the simultaneous imaging of diffuse and point-like emission in the soft gamma-ray regime. We present here all-sky images of the soft gamma-ray continuum emission that clearly reveal the morphology of the different emission components. We discuss the implications of our results on the nature of underlying emission processes and we put our results in perspective of GLAST studies of diffuse galactic continuum emission

    Imaging the Gamma-Ray Sky with SPI aboard INTEGRAL

    Get PDF
    The spectrometer SPI on INTEGRAL allows for the first time simultaneous imaging of diffuse and point-like emission in the hard X-ray and soft gamma-ray regime. To fully exploit the capabilities of the instrument, we implemented the MREM image deconvolution algorithm, initially developed for COMPTEL data analysis, to SPI data analysis. We present the performances of the algorithm by means of simulations and apply it to data accumulated during the first 2 mission years of INTEGRAL. Skymaps are presented for the 1809 keV gamma-ray line, attributed to the radioactive decay of 26Al, and for continuum energy bands, covering the range 20 keV - 3 MeV. The 1809 keV map indicates that emission is clearly detected by SPI from the inner Galactic radian and from the Cygnus region. The continuum maps reveal the transition between a point-source dominated hard X-ray sky to a diffuse emission dominated soft gamma-ray sky. From the skymaps, we extract a Galactic ridge emission spectrum that matches well SPI results obtained by model fitting. By comparing our spectrum with the cumulative flux measured by IBIS from point sources, we find indications for the existence of an unresolved or diffuse emission component above ~100 keV.Comment: 12 pages, 7 figure

    In situ three-dimensional monitoring of collagen fibrillogenesis using SHG microscopy.

    Get PDF
    International audienceWe implemented in situ time-lapse Second Harmonic Generation (SHG) microscopy to monitor the three-dimensional (3D) self-assembly of collagen in solution. As a proof of concept, we tuned the kinetics of fibril formation by varying the pH and measured the subsequent exponential increase of fibril volume density in SHG images. We obtained significantly different time constants at pH = 6.5 ± 0.3 and at pH = 7.5 ± 0.3. Moreover, we showed that we could focus on the growth of a single isolated collagen fibril because SHG microscopy is sensitive to well-organized fibrils with diameter below the optical resolution. This work illustrates the potential of SHG microscopy for the rational design and characterization of collagen-based biomaterials

    Study of SVOM/ECLAIRs inhomogeneities in the detection plane below 8 keV and their mitigation for the trigger performances

    Full text link
    The Space-based multi-band astronomical Variable Objects Monitor (SVOM) is a Chinese-French mission dedicated to the study of the transient sky. It is scheduled to start operations in 2024. ECLAIRs is a coded-mask telescope with a large field of view. It is designed to detect and localize gamma-ray bursts (GRBs) in the energy range from 4 keV up to 120 keV. In 2021, the ECLAIRs telescope underwent various calibration campaigns in vacuum test-chambers to evaluate its performance. Between 4 and 8 keV, the counting response of the detection plane shows inhomogeneities between pixels from different production batches. The efficiency inhomogeneity is caused by low-efficiency pixels (LEPs) from one of the two batches, together with high-threshold pixels (HTPs) whose threshold was raised to avoid cross-talk effects. In addition, some unexpected noise was found in the detection plane regions close to the heat pipes. We study the impact of these inhomogeneities and of the heat-pipe noise at low energies on the ECLAIRs onboard triggers. We propose different strategies in order to mitigate these impacts and to improve the onboard trigger performance. We analyzed the data from the calibration campaigns and performed simulations with the ground model of the ECLAIRs trigger software in order to design and evaluate the different strategies. Most of the impact of HTPs can be corrected for by excluding HTPs from the trigger processing. To correct for the impact of LEPs, an efficiency correction in the shadowgram seems to be a good solution. An effective solution for the heat-pipe noise is selecting the noisy pixels and ignoring their data in the 4--8 keV band during the data analysis.Comment: Accepted for publication in Astronomy&Astrophysics Accepted for publication in Astronomy&Astrophysics Accepted for publication in Astronom

    Fibrillogenesis from nanosurfaces: multiphoton imaging and stereological analysis of collagen 3D self-assembly dynamics

    No full text
    International audienceThe assembly of proteins into fibrillar structures is an important process that concerns different biological contexts, including molecular medicine and functional biomaterials. Engineering of hybrid biomaterials can advantageously provide synergetic interactions of the biopolymers with an inorganic component to ensure specific supramolecular organization and dynamics. To this aim, we designed hybrid systems associating collagen and surface-functionalized silica particles and we built a new strategy to investigate fibrillogenesis processes in such multicomponents systems, working at the crossroads of chemistry, physics and mathematics. The self-assembly process was investigated by bimodal multiphoton imaging coupling second harmonic generation (SHG) and 2 photon excited fluorescence (2PEF). The in-depth spatial characterization of the system was further achieved using the three-dimensional analysis of the SHG/2PEF data via mathematical morphology processing. Quantitation of collagen distribution around particles offers strong evidence that the chemically induced confinement of the protein on the silica nanosurfaces has a key influence on the spatial extension of fibrillogenesis. This new approach is unique in the information it can provide on 3D dynamic hybrid systems and may be extended to other associations of fibrillar molecules with optically responsive nano-objects

    Ex vivo multiscale quantitation of skin biomechanics in wild-type and genetically-modified mice using multiphoton microscopy

    Get PDF
    International audienceSoft connective tissues such as skin, tendon or cornea are made of about 90% of extracellular matrix proteins, fibrillar collagens being the major components. Decreased or aberrant collagen synthesis generally results in defective tissue mechanical properties as the classic form of Elhers-Danlos syndrome (cEDS). This connective tissue disorder is caused by mutations in collagen V genes and is mainly characterized by skin hyperextensibility. To investigate the relationship between the microstructure of normal and diseased skins and their macroscopic mechanical properties, we imaged and quantified the microstructure of dermis of ex vivo murine skin biopsies during uniaxial mechanical assay using multiphoton microscopy. We used two genetically-modified mouse lines for collagen V: a mouse model for cEDS harboring a Col5a2 deletion (a.k.a. pN allele) and the transgenic K14-COL5A1 mice which overexpress the human COL5A1 gene in skin. We showed that in normal skin, the collagen fibers continuously align with stretch, generating the observed increase in mechanical stress. Moreover, dermis from both transgenic lines exhibited altered collagen reorganization upon traction, which could be linked to microstructural modifications. These findings show that our multiscale approach provides new crucial information on the biomechanics of dermis that can be extended to all collagen-rich soft tissues
    corecore