63 research outputs found

    Quality of care associated with number of cases seen and self-reports of clinical competence for Japanese physicians-in-training in internal medicine

    Get PDF
    BACKGROUND: The extent of clinical exposure needed to ensure quality care has not been well determined during internal medicine training. We aimed to determine the association between clinical exposure (number of cases seen), self- reports of clinical competence, and type of institution (predictor variables) and quality of care (outcome variable) as measured by clinical vignettes. METHODS: Cross-sectional study using univariate and multivariate linear analyses in 11 teaching hospitals in Japan. Participants were physicians-in-training in internal medicine departments. Main outcome measure was standardized t-scores (quality of care) derived from responses to five clinical vignettes. RESULTS: Of the 375 eligible participants, 263 (70.1%) completed the vignettes. Most were in their first (57.8%) and second year (28.5%) of training; on average, the participants were 1.8 years (range = 1–8) after graduation. Two thirds of the participants (68.8%) worked in university-affiliated teaching hospitals. The median number of cases seen was 210 (range = 10–11400). Greater exposure to cases (p = 0.0005), higher self-reports of clinical competence (p = 0.0095), and type of institution (p < 0.0001) were significantly associated with higher quality of care, using a multivariate linear model and adjusting for the remaining factors. Quality of care rapidly increased for the first 100 to 200 cases seen and tapered thereafter. CONCLUSION: The amount of clinical exposure and levels of self-reports of clinical competence, not years after graduation, were positively associated with quality of care, adjusting for the remaining factors. The learning curve tapered after about 200 cases

    The ASTRO-H X-ray Observatory

    Full text link
    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.Comment: 22 pages, 17 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray

    The Quiescent Intracluster Medium in the Core of the Perseus Cluster

    Get PDF
    Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injection by the central supermassive black hole and the use of hydrostatic equilibrium for the determination of cluster masses. X-rays from the core of the Perseus cluster are emitted by the 50 million K diffuse hot plasma filling its gravitational potential well. The Active Galactic Nucleus of the central galaxy NGC1275 is pumping jetted energy into the surrounding intracluster medium, creating buoyant bubbles filled with relativistic plasma. These likely induce motions in the intracluster medium and heat the inner gas preventing runaway radiative cooling; a process known as Active Galactic Nucleus Feedback. Here we report on Hitomi X-ray observations of the Perseus cluster core, which reveal a remarkably quiescent atmosphere where the gas has a line-of-sight velocity dispersion of 164+/-10 km/s in a region 30-60 kpc from the central nucleus. A gradient in the line-of-sight velocity of 150+/-70 km/s is found across the 60 kpc image of the cluster core. Turbulent pressure support in the gas is 4% or less of the thermodynamic pressure, with large scale shear at most doubling that estimate. We infer that total cluster masses determined from hydrostatic equilibrium in the central regions need little correction for turbulent pressure.Comment: 31 pages, 11 Figs, published in Nature July

    Hitomi (ASTRO-H) X-ray Astronomy Satellite

    Get PDF
    The Hitomi (ASTRO-H) mission is the sixth Japanese x-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E  >  2  keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft x-rays to gamma rays. After a successful launch on February 17, 2016, the spacecraft lost its function on March 26, 2016, but the commissioning phase for about a month provided valuable information on the onboard instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month

    Hitomi X-Ray Studies of Giant Radio Pulses from the Crab Pulsar

    Get PDF
    To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2300 keV band and the Kashima NICT radio telescope in the 1.41.7 GHz band with a net exposure of about 2 ks on 2016 March 25, just before the loss of the Hitomi mission. The timing performance of the Hitomi instruments was confirmed to meet the timing requirement and about 1000 and 100 GRPs were simultaneously observed at the main pulse and inter-pulse phases, respectively, and we found no apparent correlation between the giant radio pulses and the X-ray emission in either the main pulse or inter-pulse phase. All variations are within the 2 fluctuations of the X-ray fluxes at the pulse peaks, and the 3 upper limits of variations of main pulse or inter-pulse GRPs are 22% or 80% of the peak flux in a 0.20 phase width, respectively, in the 2300 keV band. The values for main pulse or inter-pulse GRPs become 25% or 110%, respectively, when the phase width is restricted to the 0.03 phase. Among the upper limits from the Hitomi satellite, those in the 4.510 keV and 70300 keV bands are obtained for the first time, and those in other bands are consistent with previous reports. Numerically, the upper limits of the main pulse and inter-pulse GRPs in the 0.20 phase width are about (2.4 and 9.3) 10(exp 11) erg cm(exp 2), respectively. No significant variability in pulse profiles implies that the GRPs originated from a local place within the magnetosphere. Although the number of photon-emitting particles should temporarily increase to account for the brightening of the radio emission, the results do not statistically rule out variations correlated with the GRPs, because the possible X-ray enhancement may appear due to a >0.02% brightening of the pulse-peak flux under such conditions

    Purification and characterization of a carbonyl-reductase from human liver, which is competent in the reduction of 6-pyruvoyl-tetrahydropterin

    No full text
    An enzyme which reduces 6-pyruvoyl-tetrahydropterin has been purified to apparent homogeneity from human liver. It consists of a single polypeptide chain with a molecular weight of 35 kDa, has an isoelectric point of 5.9 ± 0.1 and contains no glycosyl residues. The pure enzyme has a specific activity of 450 mU/mg protein at pH 7.0 in 10 mM potassium phosphate buffer. It converts 6-pyruvoyl-tetrahydropterin to 6-lactoyltetrahydropterin by transfer of the pro 4R-hydrogen of NADPH to form the side chain -OH at position C(2') of the substrate. Km values are 1.8 μM for 6-pyruvoyl-tetrahydropterin and 5.5 μM for NADPH. Polyclonal antibodies raised against the purified enzyme recognize 6-pyruvoyl-tetrahydropterin reductase in Western blot and ELISA but do not cross-react with human sepiapterin reductase. The enzyme appears to be identical with aldose reductase
    corecore