28 research outputs found

    Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

    Get PDF
    We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm2 together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems)

    InGaAs/InAlAs single photon avalanche diode for 1550 nm photons.

    Get PDF
    A single photon avalanche diode (SPAD) with an InGaAs absorption region, and an InAlAs avalanche region was designed and demonstrated to detect 1550 nm wavelength photons. The characterization included leakage current, dark count rate and single photon detection efficiency as functions of temperature from 210 to 294 K. The SPAD exhibited good temperature stability, with breakdown voltage dependence of approximately 45 mV K(-1). Operating at 210 K and in a gated mode, the SPAD achieved a photon detection probability of 26% at 1550 nm with a dark count rate of 1 × 10(8) Hz. The time response of the SPAD showed decreasing timing jitter (full width at half maximum) with increasing overbias voltage, with 70 ps being the smallest timing jitter measured

    Simplified intensity- and phase-modulated transmitter for modulator-free decoy-state quantum key distribution

    Get PDF
    Quantum key distribution (QKD) allows secret key exchange between two users with unconditional security. For QKD to be widely deployed, low cost and compactness are crucial requirements alongside high performance. Currently, the majority of QKD systems demonstrated rely on bulk intensity and phase modulators to generate optical pulses with precisely defined amplitude and relative phase difference i.e., to encode information as signal states and decoy states. However, these modulators are expensive and bulky, thereby limiting the compactness of QKD systems. Here, we present and experimentally demonstrate a novel optical transmitter design to overcome this disadvantage by generating intensity- and phase-tunable pulses at GHz clock speeds. Our design removes the need for bulk modulators by employing directly modulated lasers in combination with optical injection locking and coherent interference. This scheme is, therefore, well suited to miniaturization and photonic integration, and we implement a proof-of-principle QKD demonstration to highlight potential applications

    Genetic screening of Fabry patients with EcoTILLING and HRM technology

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Anderson-Fabry disease (FD) is caused by a deficit of the α-galactosidase A enzyme which leads to the accumulation of complex sphingolipids, especially globotriaosylceramide (Gb3), in all the cells of the body, causing the onset of a multi-systemic disease with poor prognosis in adulthood. In this article, we describe two alternative methods for screening the <it>GLA </it>gene which codes for the α-galactosidase A enzyme in subjects with probable FD in order to test analysis strategies which include or rely on initial pre-screening.</p> <p>Findings</p> <p>We analyzed 740 samples using EcoTILLING, comparing two mismatch-specific<ul/>endonucleases, CEL I and ENDO-1, while conducting a parallel screening of the same samples using HRM (High Resolution Melting). Afterwards, all samples were subjected to direct sequencing. Overall, we identified 12 different genetic variations: -10C>T, -12G>A, -30G>A, IVS2-76_80del5, D165H, C172Y, IVS4+16A>G, IVS4 +68 A>G, c.718_719delAA, D313Y, IVS6-22C>T, G395A. This was consistent with the high genetic heterogeneity found in FD patients and carriers. All of the mutations were detected by HRM, whereas 17% of the mutations were not found by EcoTILLING. The results obtained by EcoTILLING comparing the CEL I and ENDO-1 endonucleases were perfectly overlapping.</p> <p>Conclusion</p> <p>On the basis of its simplicity, flexibility, repeatability, and sensitivity, we believe that<ul/>HRM analysis of the <it>GLA </it>gene is a reliable presequencing screening tool. This method can be applied to any genomic feature to identify known and unknown genetic alterations, and it is ideal for conducting screening and population studies.</p

    "Delirium Day": A nationwide point prevalence study of delirium in older hospitalized patients using an easy standardized diagnostic tool

    Get PDF
    Background: To date, delirium prevalence in adult acute hospital populations has been estimated generally from pooled findings of single-center studies and/or among specific patient populations. Furthermore, the number of participants in these studies has not exceeded a few hundred. To overcome these limitations, we have determined, in a multicenter study, the prevalence of delirium over a single day among a large population of patients admitted to acute and rehabilitation hospital wards in Italy. Methods: This is a point prevalence study (called "Delirium Day") including 1867 older patients (aged 65 years or more) across 108 acute and 12 rehabilitation wards in Italian hospitals. Delirium was assessed on the same day in all patients using the 4AT, a validated and briefly administered tool which does not require training. We also collected data regarding motoric subtypes of delirium, functional and nutritional status, dementia, comorbidity, medications, feeding tubes, peripheral venous and urinary catheters, and physical restraints. Results: The mean sample age was 82.0 \ub1 7.5 years (58 % female). Overall, 429 patients (22.9 %) had delirium. Hypoactive was the commonest subtype (132/344 patients, 38.5 %), followed by mixed, hyperactive, and nonmotoric delirium. The prevalence was highest in Neurology (28.5 %) and Geriatrics (24.7 %), lowest in Rehabilitation (14.0 %), and intermediate in Orthopedic (20.6 %) and Internal Medicine wards (21.4 %). In a multivariable logistic regression, age (odds ratio [OR] 1.03, 95 % confidence interval [CI] 1.01-1.05), Activities of Daily Living dependence (OR 1.19, 95 % CI 1.12-1.27), dementia (OR 3.25, 95 % CI 2.41-4.38), malnutrition (OR 2.01, 95 % CI 1.29-3.14), and use of antipsychotics (OR 2.03, 95 % CI 1.45-2.82), feeding tubes (OR 2.51, 95 % CI 1.11-5.66), peripheral venous catheters (OR 1.41, 95 % CI 1.06-1.87), urinary catheters (OR 1.73, 95 % CI 1.30-2.29), and physical restraints (OR 1.84, 95 % CI 1.40-2.40) were associated with delirium. Admission to Neurology wards was also associated with delirium (OR 2.00, 95 % CI 1.29-3.14), while admission to other settings was not. Conclusions: Delirium occurred in more than one out of five patients in acute and rehabilitation hospital wards. Prevalence was highest in Neurology and lowest in Rehabilitation divisions. The "Delirium Day" project might become a useful method to assess delirium across hospital settings and a benchmarking platform for future surveys

    Understanding Factors Associated With Psychomotor Subtypes of Delirium in Older Inpatients With Dementia

    Get PDF

    High Detection Rate Fast-Gated CMOS Single-Photon Avalanche Diode Module

    Get PDF
    We present a novel instrument for fast-gated operation of a 50 ÎĽm CMOS SPAD (Complementary Metal-Oxide-Semiconductor Single-Photon Avalanche Diode), driven by an integrated fast-gated active quenching circuit with transition times faster than 300 ps (20-80%). The instrument is based on a custom system-in-package where the SPAD and its driving electronics are housed in a TO-8 package. The detector can be operated at repetition rates up to 160 MHz, with gate on-times as short as 500 ps, always guaranteeing a temporal response with 60 ps (FWHM) timing jitter and short exponential decay (53 ps time-constant). A dark-count rate as low as 1 cps is achieved operating the CMOS SPAD at 5 V above breakdown at a temperature of 263 K, still keeping the afterpulsing probability lower than 2%, with only 50 ns hold-off time, thanks to the fast-gating driving electronics. The instrument is housed in a compact 5 Ă— 4 Ă— 8 cm3 case and can be triggered by either an external or internal source. A USB link allows to adjust measurement parameters, SPAD bias voltage and operating temperature. The high re-configurability of the instrument and its state-of-the-art performance make it suitable for applications where high detection rates and low timing jitter are required

    High count rate InGaAs/InP SPAD system with balanced SPAD-dummy approach running up to 1.4 GHz

    No full text
    The capability to achieve high count rates has become an imperative in the most areas where near-infrared single-photon counters are required to detect photons up to 1.7 mu m. Hence, afterpulsing mitigation is a dominant theme in recent works concerning systems based on InGaAs/InP SPADs. Given the challenges inherent in reducing the density of defects that give rise to the carrier trapping events causing afterpulsing, the only viable approach is to reduce the potential number of carriers that can be trapped by limiting the charge flow per avalanche event.In this paper we present a sine-wave gating system based on the balanced detector configuration. The gate frequency is programmable in a wide range (1.0 - 1.6 GHz) for allowing synchronization with an external laser system and for exploring the best trade-off between afterpulsing and photon detection efficiency. The long-term stability can be achieved with a stable cancelation of the gate feedthrough. In this work this is guaranteed by a feedback loop that continuously monitors the residual output power at the gate frequency and adjusts the amplitude and phase of the two sinusoids fed to the SPAD-dummy couple
    corecore