277 research outputs found

    Análise do potencial de redução do consumo de água potável pelo aproveitamento de águas pluviais e reúso de águas cinzas na Rodoviária do Plano Piloto de Brasília - DF

    Get PDF
    The aim of this work was to characterize water-uses at Plano Piloto Bus Station in Brasília and with this, this study carried out a comparative analysis of potable water reductions for rainwater harvesting and greywater reuse systems using different non-potable water use scenarios. The development of this study was divided in two stages: i) data collection of consumption; and ii) evaluation of the potential water reductions through the use of rainwater and greywater reuse. Results showed that about 80% of annual water consumption comes from floor washing and toilet and urinal flushing (3,229 m³). Based on the data collected on frequency of water use and average flow rate of equipment, it was possible to generate water end-use indicators for bathroom sink faucets (0.18 l/p/d), toilets (0.54 l/p/d), urinals (0.13 l/p/d) floor-washing (0.41 l/m²/d) and bathroom-washing (0.05 l/m²/d). Based on the data collected, it was possible to estimate the potential water reductions by the use of rainwater and the reuse of greywater for floor-washing (Scenario 1), toilet/urinal flushing (Scenario 2) and for both floor-washing and toilet/urinal flushing (Scenario 3). In general, rainwater harvesting systems promoted greater reductions in potable water consumption, varying from 601 to 3,229 m3 / year.Este trabalho teve como objetivo caracterizar os usos-finais de água da Rodoviária do Plano Piloto de Brasília e, com isso, realizou uma análise comparativa do potencial de redução de água potável entre sistemas de aproveitamento de águas pluviais e sistemas de reúso de águas cinzas em diferentes cenários de usos não potáveis. Para tanto, o desenvolvimento do estudo foi dividido em duas etapas: i) levantamento de dados de consumo; e ii) avaliação do potencial de redução do consumo de água por meio do aproveitamento da água pluvial e do reúso de águas cinzas na Rodoviária do Plano Piloto. Os resultados demonstraram que cerca de 80% do consumo anual de água da rodoviária é proveniente dos usos de água para lavagem de pisos, vasos sanitários e mictórios (3.229 m³). Com base nos dados coletados de frequências de usos, população que utilizou o banheiro e vazão dos equipamentos foi possível gerar indicadores de consumo de água lavatório (0,18 l/p/d), vaso sanitário (0,54 l/p/d), mictórios (0,13 l/p/d), lavagem de pisos (0,41 l/m²/dia) e de banheiros (0,05 l/m²/dia). Baseado nos dados coletados, foi possível estimar o potencial de redução do consumo de água potável pelo aproveitamento de águas pluviais e reúso de águas cinzas em limpeza de pisos (Cenário 1), para descarga de vasos sanitários e mictórios (Cenário 2) e descarga em vasos sanitários, mictórios e para limpeza de pisos (Cenário 3). Em geral, sistemas de aproveitamento de água pluvial promoveram maiores reduções no consumo de água potável, variando de 601 a 3.229 m3/ano

    Análise comparativa do uso de sistemas de Aproveitamento de Água Pluvial e Reúso de Águas Cinzas na Rodoviária do Plano Piloto, Brasília-DF

    Get PDF
    Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2018.Em busca de uma gestão sustentável dos recursos hídricos, propõe-se analisar o potencial de redução do consumo de água potável na Rodoviária do Plano Piloto por meio dos sistemas alternativos de abastecimento: o Aproveitamento de Água Pluvial (AAP), e o Reúso de Águas Cinzas (RAC). A metodologia foi dividida em três etapas, a primeira, tratou do levantamento de dados primários. A partir dessas informações, foi feito uma análise de correlação para avaliar quais variáveis (climáticas e tarifárias) impactam o consumo de água. Os resultados dessa análise mostraram uma relação muito baixa com as variáveis climáticas (temperatura, umidade relativa e índice de precipitação pluviométrica), com coeficiente de determinação, R2 = 0,2, e uma relação alta com as tarifas aplicadas, com um R2 =0,7. Diante disso, pode-se afirmar que o comportamento das pessoas que utilizam o espaço é pouco influenciado por fatores externos, e que a principal variável impactante é a tarifa aplicada. A segunda etapa tem uma abordagem qualitativa, e nesta, foram caracterizados todos os usos finais e equipamentos hidráulicos da edificação, e registradas as frequências de uso em cada ponto de consumo dos banheiros públicos. O resultado mostrou que nos banheiros masculinos, a maior parte do consumo vem dos lavatórios com uma proporção de uso entre 40% e 60%, seguido dos mictórios entre 30% e 50% e vaso sanitário entre 4% e 15%. Nos banheiros femininos o principal consumo, também, vem dos lavatórios com proporção de uso entre 60% e 70%, seguido dos usos em vasos sanitários entre 30% e 40%. Apesar desse padrão de consumo ser maior nos lavatórios, os vaso sanitários e os mictórios são os principais consumidores de água, com média de gasto diário de 7.214 litros, contra 1.889 litros que são utilizados nos pontos de lavatórios. Com esses dados, também foram construídos os indicadores de consumo, que permite prever o consumo de água através do número de pessoas que frequentam os banheiros e em relação à área lavável da edificação. Assim, para os vasos sanitários o indicador de consumo é de 0,54 litros por pessoa por dia (L/P/dia). Para os mictórios é de 0,13L/P/dia, para os lavatórios, são 0,18L/P/dia e para a lavagem de pisos, o indicador é de 0,06 L/m2/dia. Por fim, a terceira etapa, avalia o potencial de redução de consumo através dos sistemas de AAP e RAC, estes foram dimensionados e foi identificado que o sistema de RAC só é capaz de produzir água suficiente para a lavagem de pisos, essa medida promove uma redução anual no consumo de água de 15%, 601 m3 de água, com um reservatório de apenas 1.500 L. Já o AAP tem capacidade para abastecer todos os fins não potáveis e tem potencial de redução do consumo anual de até 80%, 3.229m3. Esse valor expressivo só é possível porque o consumo nos fins não potáveis é muito superior ao fim potável (lavatórios). Devido ao longo período de estiagem no DF, o volume do reservatório necessário para atender essa demanda é de 1.761 m3, um valor bastante alto, que para ser implantado é necessário fazer um projeto de escavação no subsolo para posicionar o reservatório de armazenagem. Diante disso, foi dimensionado o sistema misto para verificar se fazendo o reúso de água cinza para a lavagem de pisos e utilizando o aproveitamento da água pluvial para os demais fins não potáveis, acarretaria em uma redução no reservatório de AAP mantendo o alto potencial de redução do consumo. Neste caso o reservatório continuou muito grande 1.433 m3. No entanto pode ser uma alternativa para implantar esse sistema por etapas, primeiro começar com o reúso, e depois implantar o sistema de AAP, de maior volume.In search for a sustainable management of water resources it is proposed on this research to analyze the potential of reducing the consumption of drinking water in the Plano Piloto Bus Station through alternative supply systems: Rainwater harvesting (RWH) and Greywater recycling (GWR). The methodology was divided into three stages, the first one dealt with the collection of primary data. From this Information, a correlation analysis was made to evaluate which variables (climatic and tariff) impact the most on the water consumption. The results of this analysis showed a very low relation with the climatic variables (temperature, relative humidity and rainfall index), with coefficient of determination, R2 = 0.2, and a high relation with applied tariffs, with a R2 = 0,7. Therefore, it can be said that the behavior of the people who use the space is little influenced by externai factors, and that the main impact variable is the applied tariff on the consumption bill. The second stage has a qualitative approach, and in this, all the end uses and hydraulic equipment of the building, and recorded the frequencies of use in each point of consumption of public toilets were characterized. The results showed that in men's restrooms, most of the consumption comes from washbasins with a 40-60% use rate, followed by urinais between 30% and 50% and the toilet between 4% and 15%. In women's restrooms the main consumption also comes from the use of washbasins between 60% and 70%, followed by the toilet use between 30% and 40%. Although consumption pattern is greater in washbasins, the toilets and urinais consumption are the main water volume data, with a daily average of 7,214 liters, against 1,889 liters that are used in washbasin points. With these data, the consumption indicators were also calculated, which allowed to predict the water consumption over the number of people who attend the bathrooms and the relation to the washable area of the building. Therefore, for the toilets the consumption indicator is 0.54 liters per person per day (L/P/day). For urinais it is 0.13L/P/day, for washbasins is 0.18L/P/day and for washing floors, the indicator is 0.06L/m2/day. Finally, the third stage evaluates the potential of reducing consumption through the RWH and GWR systems, these were sized and it was identified that the RWH system is only capable of producing enough water for floor washing end use, this measure promotes an annual reduction in water consumption of 15%, 601 m3, with a reservoir of only 1,500 L. The RWH has the capacity to supply all non-potable purposes and has the potential to reduce annual consumption of up to 80%, 3,229m3. This expressive value is only possible because consumption at non-potable end uses is much higher than the drinking end (washbasins). Due to the long dry season in DF, the volume of the reservoir needed to meet this demand is 1,761 m3, a very high value, which to be implanted it is necessary to make an excavation project in the basement to position the storage tank. Therefore, the mixed system was sized to verify if using the GWR for washing of floors and using the RWH for other non- potable purposes, would result in a reduction in the RWH reservoir maintaining the high reduction potential of consumption. In this case the reservoir continued very large 1,433 m3. However, it can be an alternative to deploy this system in steps, first to start with the GWR, and then deploy the larger volume with RWH system

    GREEN PEDESTRIAN CROSSING: Arte, Espaço Urbano e Cidadania

    Get PDF
    Reflexão do homem e suas escolhas, do homem e sua ação com o entorno com base na obra Green Pedestrian Crossing

    Geology, Petrology and Magmatic Evolution of the Felsic Alkaline Rocks of the Vitória Island, São Paulo State, Brazil

    Get PDF
    This paper presents geological, petrographic, geochemical characteristics and radiometric ages for the felsic alkaline rocks of the Vitória Island Intrusive Complex, São Paulo State, Brazil, and discusses its geochemical evolutionary processes. This intrusive body is about 3 km in diameter and the emerged island areas correspond to its northeastern border. The main intrusion is constituted by nepheline syenite at the central zone, nepheline-bearing syenite at the outer zone, syenite at the border, and quartz syenite at the contact zone with alkali feldspar represented by orthoclase. Clinopyroxene vary from hedenbergite, soda-augite to aegirine-augite, and some crystals have resorption shape and amphibole reaction rim. They are intruded by phonolite, trachyte and lamprophyre dykes. Based on the intrusion relation, the dykes are subdivided into two generations: the first one encompass a radial system and the second a parallel system with NE-SW orientation and sinistral displacement. The alkaline rocks vary from silica undersaturated to oversaturated, show peralkaline to peraluminous compositions and belong to the potassic series. The K-Ar ages for amphibole of the nepheline-bearing syenite and syenite are 89.58 ± 3.18 Ma and 84.35 ± 3.92 Ma, respectively. The rocks are strongly fractionated with high differentiation index (DI) of 88.15 in average, indicating mafic minerals fractionation. K2O/ (K2O+Na2O) ratios are low, in average 0.51, in accordance to crystallization of pseudo leucite and potassic feldspar the last observed in thin sections

    Análise do potencial de redução do consumo de água potável pelo aproveitamento de águas pluviais e reúso de águas cinzas na Rodoviária do Plano Piloto de Brasília - DF

    Get PDF
    Este trabalho teve como objetivo caracterizar os usos-finais de água da Rodoviária do Plano Piloto de Brasília e, com isso, realizou uma análise comparativa do potencial de redução de água potável entre sistemas de aproveitamento de águas pluviais e sistemas de reúso de águas cinzas em diferentes cenários de usos não potáveis. Para tanto, o desenvolvimento do estudo foi dividido em duas etapas: i) levantamento de dados de consumo; e ii) avaliação do potencial de redução do consumo de água por meio do aproveitamento da água pluvial e do reúso de águas cinzas na Rodoviária do Plano Piloto. Os resultados demonstraram que cerca de 80% do consumo anual de água da rodoviária é proveniente dos usos de água para lavagem de pisos, vasos sanitários e mictórios (3.229 m³). Com base nos dados coletados de frequências de usos, população que utilizou o banheiro e vazão dos equipamentos foi possível gerar indicadores de consumo de água lavatório (0,18 l/p/d), vaso sanitário (0,54 l/p/d), mictórios (0,13 l/p/d), lavagem de pisos (0,41 l/m²/dia) e de banheiros (0,05 l/m²/dia). Baseado nos dados coletados, foi possível estimar o potencial de redução do consumo de água potável pelo aproveitamento de águas pluviais e reúso de águas cinzas em limpeza de pisos (Cenário 1), para descarga de vasos sanitários e mictórios (Cenário 2) e descarga em vasos sanitários, mictórios e para limpeza de pisos (Cenário 3). Em geral, sistemas de aproveitamento de água pluvial promoveram maiores reduções no consumo de água potável, variando de 601 a 3.229 m3/ano.The aim of this work was to characterize water-uses at Plano Piloto Bus Station in Brasília and with this, this study carried out a comparative analysis of potable water reductions for rainwater harvesting and greywater reuse systems using different non-potable water use scenarios. The development of this study was divided in two stages: i) data collection of consumption; and ii) evaluation of the potential water reductions through the use of rainwater and greywater reuse. Results showed that about 80% of annual water consumption comes from floor washing and toilet and urinal flushing (3,229 m³). Based on the data collected on frequency of water use and average flow rate of equipment, it was possible to generate water end-use indicators for bathroom sink faucets (0.18 l/p/d), toilets (0.54 l/p/d), urinals (0.13 l/p/d) floor-washing (0.41 l/m²/d) and bathroom-washing (0.05 l/m²/d). Based on the data collected, it was possible to estimate the potential water reductions by the use of rainwater and the reuse of greywater for floor-washing (Scenario 1), toilet/urinal flushing (Scenario 2) and for both floor-washing and toilet/urinal flushing (Scenario 3). In general, rainwater harvesting systems promoted greater reductions in potable water consumption, varying from 601 to 3,229 m3 / year

    Satellite-based estimates of groundwater storage variations in large drainage basins with extensive floodplains

    No full text
    International audienceThis study presents monthly estimates of groundwater anomalies in a large river basin dominated by extensive floodplains, the Negro River Basin, based on the synergistic analysis using multisatellite observations and hydrological models. For the period 2003-2004, changes in water stored in the aquifer is isolated from the total water storage measured by GRACE by removing contributions of both the surface reservoir, derived from satellite imagery and radar altimetry, and the root zone reservoir simulated by WGHM and LaD hydrological models. The groundwater anomalies show a realistic spatial pattern compared with the hydrogeological map of the basin, and similar temporal variations to local in situ groundwater observations and altimetry-derived level height measurements. Results highlight the potential of combining multiple satellite techniques with hydrological modeling to estimate the evolution of groundwater storage

    ZPD-2, a small compound that inhibits α-synuclein amyloid aggregation and its seeded polymerization

    Get PDF
    Altres ajuts: SV was supported by the ICREA (ICREA-Academia 2015) and the Fundación La Marató de TV3 (Ref. 20144330). JavS was supported by the Gobierno de Aragón (E45_17R). ED was supported by the Instituto de Salud Carlos III (PH613883/ERDF/ESF).α-Synuclein (α-Syn) forms toxic intracellular protein inclusions and transmissible amyloid structures in Parkinson's disease (PD). Preventing α-Syn self-assembly has become one of the most promising approaches in the search for disease-modifying treatments for this neurodegenerative disorder. Here, we describe the capacity of a small molecule (ZPD-2), identified after a high-throughput screening, to inhibit α-Syn aggregation. ZPD-2 inhibits the aggregation of wild-type α-Syn and the A30P and H50Q familial variants in vitro at substoichiometric compound:protein ratios. In addition, the molecule prevents the spreading of α-Syn seeds in protein misfolding cyclic amplification assays. ZPD-2 is active against different α-Syn strains and blocks their seeded polymerization. Treating with ZPD-2 two different PD Caenorhabditis elegans models that express α-Syn either in muscle or in dopaminergic (DA) neurons substantially reduces the number of α-Syn inclusions and decreases synuclein-induced DA neurons degeneration. Overall, ZPD-2 is a hit compound worth to be explored in order to develop lead molecules for therapeutic intervention in PD

    Effective Combination Immunotherapy with Oncolytic Adenovirus and Anti-PD-1 for Treatment of Human and Murine Ovarian Cancers

    Get PDF
    Ovarian cancer (OvCa) is one of the most common gynecological cancers and has the highest mortality in this category. Tumors are often detected late, and unfortunately over 70% of OvCa patients experience relapse after first-line treatments. OvCa has shown low response rates to immune checkpoint inhibitor (ICI) treatments, thus leaving room for improvement. We have shown that oncolytic adenoviral therapy with Ad5/3-E2F-d24-hTNFa-IRES-hIL2 (aka. TILT-123) is promising for single-agent treatment of cancer, but also for sensitizing tumors for T-cell dependent immunotherapy approaches, such as ICI treatments. Therefore, this study set out to determine the effect of inhibition of the immune checkpoint inhibitors (ICI), in the context of TILT-123 therapy of OvCa. We show that simultaneous treatment of patient derived samples with TILT-123 and ICIs anti-PD-1 or anti-PD-L1 efficiently reduced overall viability. The combinations induced T cell activation, T cells expressed activation markers more often, and the treatment caused positive microenvironment changes, measured by flow cytometric assays. Furthermore, in an immunocompetent in vivo C57BL/6NHsda mouse model, tumor growth was hindered, when treated with TILT-123, ICI or both. Taken together, this study provides a rationale for using TILT-123 virotherapy in combination with TILT-123 and immune checkpoint inhibitors together in an ovarian cancer OvCa clinical trial.Peer reviewe
    corecore