365 research outputs found

    Conceptual design of elliptical cavities for intensity and position sensitive beam measurements in storage rings

    Full text link
    Position sensitive beam monitors are indispensable for the beam diagnostics in storage rings. Apart from their applications in the measurements of beam parameters, they can be used in non-destructive in-ring decay studies of radioactive ion beams as well as enhancing precision in the isochronous mass measurement technique. In this work, we introduce a novel approach based on cavities with elliptical cross-section, in order to compensate for existing limitations in ion storage rings. The design is aimed primarily for future heavy ion storage rings of the FAIR project. The conceptual design is discussed together with simulation results.Comment: Added definition of Uv and Pdiss in the introduction section. Added Mode numbering in table 1 and figure 1 for more clarity. Corrected one wrong figure reference. Other minor typo correction

    Perfluorocarbon liquid migration into the subarachnoid space in a patient with morning glory syndrome

    Get PDF
    Purpose: To report a case of perfluorocarbon liquid (PFCL) migration into the subarachnoid space at the time of vitreoretinal surgery in a patient with morning glory syndrome associated retinal detachment. Case report: A 9-year-old girl underwent pars plana vitrectomy and silicone oil injection for retinal detachment associated with morning glory syndrome. PFCL was used for retinal stabilization before endolaser photocoagulation. The retina detached, and repeated vitrectomy and silicone oil injection was performed. Postoperative magnetic resonance imaging revealed PFCL in the subarachnoid space. Conclusion: The migration of perfluorocarbon into the subarachnoid space is a rare complication of vitrectomy in patients with morning glory syndrome. © 2015 Iranian Society of Ophthalmology

    Causes of Death Accompanying by Soft Tissue Neck Hemorrhage

    Get PDF
    Background: Generally, soft tissue hemorrhages in anterior part of the neck are attributed to the neck compression or trauma and suspicion goes more to homicidal death than suicide. Although artificial posterior neck hemorrhages are described as Prinsloo-Gordon phenomenon in cadavers with posterior lividity, studies conducted on such hemorrhages in the anterior and lateral compartments are rare. This study intends to investigate causes of death accompanied by soft tissue neck hemorrhages in different compartments of neck. Method: In this retrospective case series, between March 2008 and 2009, cadavers whose autopsies indicated soft tissue neck hemorrhages and the lividity was dominant in posterior, were evaluated according to the cause of death and anatomical and histological locations of hemorrhage. Results: Among 86 cases of neck hemorrhage, 72.1% (n=62) were male. Direct neck trauma, hanging, strangulation, chocking and positional asphyxia constituted 50% (n=43) of them, 40.7% (n=35) were non-asphyxial, non-traumatic deaths such as natural diseases, drug and CO poisoning, electrocution and drowning, and 9.3% (n=8) were unknown. 65.1% (n=28) of non-traumatic, non-asphyxial cases bore anterior or lateral neck hemorrhages. Conclusion: The considerable prevalence of soft neck tissue hemorrhages in non asphyxial deaths with no history of neck trauma and the location of such hemorrhages in anterior and lateral sides of neck, lead the investigators to pay more attention to interpret these hemorrhages and determining the mode and cause of death

    Assessment of correlation between electrogoniometer measurements and sports-specific movement in karate elites

    Get PDF
    Purpose: To examine the intra-rater reliability of knee movement data in sagital plane obtained from electrogoniometer (EGM) in a basic, sport-specific task of karate. Methods: A total of 23 elite karate athletes (13 females and 10 males; mean age of 16.10±1.26 yrs) participated in this study. The task was defined as performing three consecutive Zenkutsu-dachi in two sessions. The used EGM was a twin axis of Biometrics company. EGM curves were plotted in MATLAB software separately. The indices of three points in the plots corresponding to extremes of flexion and extension of knee in the first dachi were determined. There was also another (forth) point which was not in extremes of movement. As it was repeated in all curves, it was perceived as a biomechanical event and was assessed. The phases of movement between the points were scaled between 0 to 100 of activity. Results: Repeatability of the forth point index was assessed by intraclass correlation method. Intraclass correlation of the ratio in the first testing session was 0.666 and in second was 0.448. The interval between points were considered as phases of movement. After determining three phases of dachi, it was shown that these phases pertained a specific ratio of the total plot which were 48, 36 and 16 of total respectively. Conclusion: Dachi could be divided into three distinct phases; each of them should constitute a specific percent of the total in an elite athlete. © 2014 by Sports Medicine Research Center, Tehran University of Medical Sciences, All rights reserved

    The effect of increasing volume of exercise on activation pattern of vastus medialis and lateralis and its correlation with anterior knee pain in karate elites

    Get PDF
    Background: The effects of exercise volume on the pattern of muscle activity is one of the most important factors in training management and injury risk reduction. In the lower limb, the quadriceps muscle which plays a determining role in performing the stance and other karate techniques could be injured in intensive exercise and may induce anterior knee pain in athletes. Objectives: The aim of this study was to determine the relationship between training volume and muscle activity of vastus medialis and vastus lateralis and its association with anterior knee pain in karate elites. Patients and Methods: Male and female athletes from national junior and cadet karate team (14 to 18 years) were invited to participate in the study at the beginning and the end of the training camps. Studies involved measurement of electromyographic muscle activity of vastus medialis and vastus lateralis in both lower extremities with surface electromyography device and assessment of movement by electrogoniometery. Muscle activity was recorded in three tests of dachi, walking up and walking down stairs. Simultaneously, anterior knee pain was evaluated using visual analogue scale and anterior knee pain scale questionnaire. Results: Eight athletes of a total number of 23 reported increased ratings of pain in their right knees. No differences in muscle activity were observed in tests of Dachi and stairs between the groups with and without pain. Comparing Dachi task pattern at the beginning and end of training camps, there was no significant difference in pattern of biomechanical movement; however, reducing the amount of muscle activity in early and late phases of tasks was observed in electromyographic assessment. Conclusions: The results showed that performing the same task after a six-week training period, less muscle activity was required in all phases in two groups of tasks, including karate-specific movement (dachi) and activities of daily living (up or down stairs). © 2016, Sports Medicine Research Center

    Nuclear Physics Experiments with Ion Storage Rings

    Get PDF
    In the last two decades a number of nuclear structure and astrophysics experiments were performed at heavy-ion storage rings employing unique experimental conditions offered by such machines. Furthermore, building on the experience gained at the two facilities presently in operation, several new storage ring projects were launched worldwide. This contribution is intended to provide a brief review of the fast growing field of nuclear structure and astrophysics research at storage rings.Comment: XVIth International Conference on Electro-Magnetic Isotope Separators and Techniques Related to their Applications, December 2--7, 2012 at Matsue, Japa
    corecore