2,100 research outputs found

    Planck LFI flight model feed horns

    Full text link
    this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed horns each connected to the Radiometer Chain Assembly (RCA). This paper describes the design, the manufacturing and the testing of the flight model feed horns. They have been designed to optimize the LFI optical interfaces taking into account the tight mechanical requirements imposed by the Planck focal plane layout. All the eleven units have been successfully tested and integrated with the Ortho Mode transducers.Comment: This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T1200

    Milk acidity, curd firming time, curd firmness and protein and fat losses in the Parmigiano- Reggiano cheesemaking

    Get PDF
    The cheese yield depends on the milk casein content and on the fat to casein ratio. The efficiency of the milk transformation depends on curd particles ("curd fines") that remain in the cooked whey and on the losses of fat and casein as it is

    Linear Ramps of Interaction in the Fermionic Hubbard Model

    Full text link
    We study the out of equilibrium dynamics of the Fermionic Hubbard Model induced by a linear ramp of the repulsive interaction UU from the metallic state through the Mott transition. To this extent we use a time dependent Gutzwiller variational method and complement this analysis with the inclusion of quantum fluctuations at the leading order, in the framework of a Z2Z_2 slave spin theory. We discuss the dynamics during the ramp and the issue of adiabaticity through the scaling of the excitation energy with the ramp duration τ\tau. In addition, we study the dynamics for times scales longer than the ramp time, when the system is again isolated and the total energy conserved. We establish the existence of a dynamical phase transition analogous to the one present in the sudden quench case and discuss its properties as a function of final interaction and ramp duration. Finally we discuss the role of quantum fluctuations on the mean field dynamics for both long ramps, where spin wave theory is sufficient, and for very short ramps, where a self consistent treatment of quantum fluctuations is required in order to obtain relaxation.Comment: v2: 19 pages, 14 figures, published versio

    Comparing Catalysts of the Direct Synthesis of Hydrogen Peroxide in Organic Solvent: is the Measure of the Product an Issue?

    Get PDF
    The direct synthesis of hydrogen peroxide has been for about 20 years a hot topic in \u201cgreen\u201d catalysis. Several methods, which are well established to measure the concentration of hydrogen peroxide in water are also applied to the analysis of reaction mixtures from the direct synthesis of H2O2. However, this step could not be always straightforward, because these mixtures contain almost invariably organic solvents and, sometimes, selectivity enhancers which can interfere in some, at the least, of the most popular titrimetric methods. This work presents a comparative investigation of iodometry, cerimetry, permanganometry (titrimetric methods) and spectrophotometric analysis of TiIV/H2O2 adduct, as applied to analysis of hydrogen peroxide produced by its direct synthesis. They account for more than 90 % of the competent literature since 2000. Their pros and cons are highlighted to provide a guideline for the choice of the best possible method of analysis and for the comparison of catalytic results assessed in different ways in the context of the direct synthesis of hydrogen peroxide

    The GRAAL high resolution BGO calorimeter and its energy calibration and monitoring system

    Get PDF
    We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy calibration accuracy and stability reached is a small fraction of the intrinsic detector resolution.Comment: 19 pages, 14 figures, submitted to Nuclear Instruments and Method

    Planck-LFI radiometers' spectral response

    Get PDF
    The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.Comment: 16 pages, 9 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jins
    corecore