173 research outputs found

    Strategies to define performance specifications in laboratory medicine: 3 years on from the Milan Strategic Conference

    Get PDF
    Measurements in clinical laboratories produce results needed in the diagnosis and monitoring of patients. These results are always characterized by some uncertainty. What quality is needed and what measurement errors can be tolerated without jeopardizing patient safety should therefore be defined and specified for each analyte having clinical use. When these specifications are defined, the total examination process will be "fit for purpose" and the laboratory professionals should then set up rules to control the measuring systems to ensure they perform within specifications. The laboratory community has used different models to set performance specifications (PS). Recently, it was felt that there was a need to revisit different models and, at the same time, to emphasize the presuppositions for using the different models. Therefore, in 2014 the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) organized a Strategic Conference in Milan. It was felt that there was a need for more detailed discussions on, for instance, PS for EQAS, which measurands should use which models to set PS and how to set PS for the extra-analytical phases. There was also a need to critically evaluate the quality of data on biological variation studies and further discussing the use of the total error (TE) concept. Consequently, EFLM established five Task Finish Groups (TFGs) to address each of these topics. The TFGs are finishing their activity on 2017 and the content of this paper includes deliverables from these groups

    The European Biological Variation Study (EuBIVAS): Biological Variation Data for Coagulation Markers Estimated by a Bayesian Model.

    Get PDF
    Abstract Background For biological variation (BV) data to be safely used, data must be reliable and relevant to the population in which they are applied. We used samples from the European Biological Variation Study (EuBIVAS) to determine BV of coagulation markers by a Bayesian model robust to extreme observations and used the derived within-participant BV estimates [CVP(i)] to assess the applicability of the BV estimates in clinical practice. Method Plasma samples were drawn from 92 healthy individuals for 10 consecutive weeks at 6 European laboratories and analyzed in duplicate for activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen, D-dimer, antithrombin (AT), protein C, protein S free, and factor VIII (FVIII). A Bayesian model with Student t likelihoods for samples and replicates was applied to derive CVP(i) and predicted BV estimates with 95% credibility intervals. Results For all markers except D-dimer, CVP(i) were homogeneously distributed in the overall study population or in subgroups. Mean within-subject estimates (CVI) were <5% for APTT, PT, AT, and protein S free, <10% for protein C and FVIII, and <12% for fibrinogen. For APTT, protein C, and protein S free, estimates were significantly lower in men than in women ≤50 years. Conclusion For most coagulation markers, a common CVI estimate for men and women is applicable, whereas for APTT, protein C, and protein S free, sex-specific reference change values should be applied. The use of a Bayesian model to deliver individual CVP(i) allows for improved interpretation and application of the data

    Sick leave, disability, and mortality in acute hepatic porphyria: a nationwide cohort study

    Get PDF
    Background: Acute hepatic porphyria (AHP) consists of three rare metabolic disorders. We investigated the risk of long-term sick leave, disability pension, and premature death in individuals with AHP compared to the general population. Methods: In a nationwide cohort study from 1992 to 2017, records of 333 persons (total person-years = 6728) with a confirmed AHP diagnosis were linked to several national compulsory registries (reference population = 5,819,937). We conducted survival analyses to assess additional risk. Results: Persons with AHP had higher risks of accessing long-term sick leave (adjusted hazard ratio (aHR): 1.5, 95% confidence interval (CI): 1.3, 1.7) and disability pension (aHR: 1.9, CI: 1.5, 2.4). The risk was highest in persons who had been hospitalised for acute attacks, while no additional risk was observed in asymptomatic AHP gene mutation carriers. The median age when accessing disability pension was 45 years, 21 years younger than the general population. AHP was associated with increased risk of mortality due to hepatocellular carcinoma (adjusted mortality rate ratio (aMRR): 84.4, CI: 37.8, 188.2), but no overall increased risk of premature death was observed. Conclusions: Persons with symptomatic AHP were at increased risk of accessing long-term sick leave and disability pension but not of premature death.publishedVersio

    Spirometry in chronic obstructive pulmonary disease in Norwegian general practice

    Get PDF
    Background General practitioners (GPs) in Norway increasingly use spirometry diagnostically as well as in follow up of patients with respiratory complaints, but little is known about their skills and knowledge in this area. The aim of the present study was to investigate how GPs interpret a case history and spirometry recordings of a patient with chronic obstructive pulmonary disease (COPD), and their knowledge about their own spirometer. Methods A web-based survey, consisting of a case history and spirometry recordings of a patient with COPD, was distributed to the 4700 members of the Norwegian GP Association. In addition to background information about themselves and their spirometer, topics included whether they requested, and how they interpreted, a spirometry reversibility-test, identification of the of most likely diagnosis, and recognition of the spirometry parameters used to diagnose COPD and grade airway obstruction. Immediate feedback was provided for educational purposes. Results Six hundred thirty GPs responded. Twenty six percent would not request a reversibility test, but 81% identified COPD as the most likely diagnosis. Less than 50% correctly identified the spirometry parameters used for diagnosis of COPD and grading the airway obstruction. One in five (21%) did not know which spirometer was used in their own practice, and 49 and 61% did not know which reference values were used for adults and children, respectively. Participants evaluated the survey as useful (average 74 points on a 0–100 scale) and would like more case-based surveys concerning use of spirometry in the future (average 91 points). Conclusion In this cohort of self-selected GPs, probably more interested in respiratory medicine than the average GP, we identified several problem areas and gaps in knowledge regarding the use of spirometry.publishedVersio

    Performance of Afinion HbA1c measurements in general practice as judged by external quality assurance data

    Get PDF
    Background: It has been debated whether point-of care (POC) glycated hemoglobin (HbA1c) measurements methods can be used for diagnosing persons with diabetes mellitus. The aim of this study was to evaluate the analytical performance of the POC Afinion HbA1c system in the hands of the users, and to investigate which predictors that were associated with good participant performance. Methods: External quality assurance (EQA) data from seven surveys in 2017–2018 with a total of 5809 Afinion participants from a POC total quality system in Norway were included in this study (response rate 90%). The control materials were freshly drawn pooled EDTA whole blood. Each participant was evaluated against the analytical performance specification of ±6% from the target value, while the Afinion system was evaluated against the pooled within-laboratory CV <2%, the between-laboratory CV <3.5%, and bias <0.3%HbA1c. Logistic regression analyses were used to investigate which factors were associated with good participant performance. Results: The participant pass rates for each survey varied from 98.2% to 99.7%. The pooled within-laboratory CV varied from 1.3% to 1.5%, the between-laboratory CV varied from 1.5% to 2.1%, and bias varied between −0.17 and −0.01 %HbA1c in all surveys. Reagent lot was the only independent factor to predict good participant performance. Conclusions: Afinion HbA1c fulfilled the analytical performance specifications and is robust in the hands of the users. It can therefore be used both in diagnosing and monitoring persons with diabetes mellitus, given that the instrument is monitored by an EQA system.publishedVersio

    Conformational stability and activity analysis of two hydroxymethylbilane synthase mutants, K132N and V215E, with different phenotypic association with acute intermittent porphyria

    Get PDF
    The autosomal dominantly inherited disease AIP (acute intermittent porphyria) is caused by mutations in HMBS [hydroxymethylbilane synthase; also known as PBG (porphobilinogen) deaminase], the third enzyme in the haem biosynthesis pathway. Enzyme-intermediates with increasing number of PBG molecules are formed during the catalysis of HMBS. In this work, we studied the two uncharacterized mutants K132N and V215E comparative with wt (wild- type) HMBS and to the previously reported AIP-associated mutants R116W, R167W and R173W. These mainly present defects in conformational stability (R116W), enzyme kinetics (R167W) or both (R173W). A combination of native PAGE, CD, DSF (differential scanning fluorimetry) and ion-exchange chromatography was used to study conformational stability and activity of the recombinant enzymes. We also investigated the distribution of intermediates corresponding to specific elongation stages. It is well known that the thermostability of HMBS increases when the DPM (dipyrromethane) cofactor binds to the apoenzyme and the holoenzyme is formed. Interestingly, a decrease in thermal stability was measured concomitant to elongation of the pyrrole chain, indicating a loosening of the structure prior to product release. No conformational or kinetic defect was observed for the K132N mutant, whereas V215E presented lower conformational stability and probably a perturbed elongation process. This is in accordance with the high association of V215E with AIP. Our results contribute to interpret the molecular mechanisms for dysfunction of HMBS mutants and to establish genotype–phenotype relations for AIP.publishedVersio

    Key Terms and Definitions in Acute Porphyrias: Results of an International Delphi Consensus Led by the European Porphyria Network

    Get PDF
    Background: Acute porphyrias are a group of rare inherited disorders causing acute neurovisceral attacks. Many terms used frequently in the literature and in clinical practice are ambiguous, which can lead to confusion in the way patients are managed, studied, and reported in clinical studies. Agreed definitions are a necessary first step in developing management guidelines and will facilitate communication of results of future clinical research. Methods: The Delphi method was used to generate consensus on key terms and definitions in acute porphyria. The process started with a brainstorming phase offered to all members of the European Porphyria Network followed by 2 Delphi rounds among international experts in the field of porphyria (the Acute Porphyria Expert Panel). A consensus of 75% or more was defined as the agreement threshold. Results: 63 respondents from 26 countries participated in the brainstorming phase, leading to the choice of 9 terms and definitions. 34 experts were invited to take part in the Delphi rounds. 7 of the initial 9 terms and definitions which entered the first Delphi round achieved the threshold for agreement. Following a second Delphi round, all 9 definitions achieved agreement. Conclusion: Agreement on the definitions for 9 important terms describing acute porphyrias represents a significant step forward for the porphyria community. It will facilitate more accurate comparison of outcomes among porphyria centres and in clinical trials and provide a strong framework for developing evidence based clinical guidelines

    Evaluation of eleven rapid tests for detection of antibodies against SARS-CoV-2

    Get PDF
    Objectives: SARS-CoV-2, causing COVID-19, has emerged to cause a human pandemic. Detection of SARS-CoV-2 in respiratory samples by using PCR is the standard laboratory diagnostic tool. Our aim was to perform a limited evaluation of the diagnostic performance and user-friendliness of eleven rapid tests for detection of antibodies against SARS-CoV-2. Methods: All participants were tested with PCR against SARS-CoV-2 at a clinical microbiology laboratory. Comparing with results from PCR tests, we evaluated the rapid tests’ performances in three arms; 1) 20 hospitalized patients with PCR-confirmed COVID-19, 2) 23 recovered outpatients with former PCR-confirmed COVID-19, and 3) 49 participants with suspected COVID-19 presenting at a primary care emergency room. Results: All eleven tests detected antibodies in hospitalized COVID-19 patients, though with varying sensitivities. In former outpatients recovered from COVID-19, there were differences between tests in the immunoglobulin type G (IgG) sensitivity, with five tests having a sensitivity below 65%. In participants with suspected COVID-19 infection, the rapid tests had very low sensitivities. Most rapid tests were easy to perform and interpret. Conclusions: Rapid tests were not suited as stand-alone tests to detect present infection in a Norwegian primary care emergency room population. All the rapid tests were able to detect SARS-CoV-2 antibodies, although sensitivities varied and were generally higher in the study arm of more severely affected participants. Rapid tests with high IgG sensitivity (and specificity) may be useful for confirmation of past infection. An independent evaluation should be performed in the intended population before introducing a rapid test.publishedVersio

    Performance and user-friendliness of the rapid antigen detection tests QuickVue Dipstick Strep A test and DIAQUICK Strep A Blue Dipstick for pharyngotonsillitis caused by Streptococcus pyogenes in primary health care

    Get PDF
    Sensitivity and specificity of rapid antigen detection tests (RADTs) for detection of group A hemolytic streptococcus (GAS) vary. The purpose is to present the first SKUP (Scandinavian evaluation of laboratory equipment for point of care testing) evaluations concerning the assessment of the diagnostic performance and user-friendliness of two RADTs for detection of GAS when used under real-life conditions in primary health care. Throat samples were collected in duplicates at primary health care centers (PHCCs) from patients with symptoms of pharyngitis. The performance of QuickVue Dipstick Strep A test (307 samples) and DIAQUICK Strep A Blue Dipstick (348 samples) was evaluated using culture results at a clinical microbiology laboratory as comparison. The user-friendliness was evaluated using a questionnaire. The diagnostic sensitivity was 92% (90% confidence interval (CI) 87–96%) and 72% (90% CI 65–79%), while the diagnostic specificity was 86% (90% CI 81–90%) and 98% (90% CI 96–99%) for QuickVue Dipstick Strep A test and DIAQUICK Strep A Blue Dipstick, respectively. Both RADTs obtained acceptable assessments for user-friendliness and fulfilled SKUP’s quality goal for user-friendliness. The diagnostic sensitivity for QuickVue Dipstick Strep A test and the diagnostic specificity for DIAQUICK Strep A Blue Dipstick in this objective and supplier-independent evaluation were higher compared with previous meta-analyses of RADTs. However, the diagnostic specificity for QuickVue Dipstick Strep A test and the diagnostic sensitivity for DIAQUICK Strep A Blue Dipstick were lower compared with previous meta-analyses of RADTs.publishedVersio
    • …
    corecore