    Effect of influenza-induced fever on human bioimpedance values

    Get PDF
    BACKGROUND AND AIMS: Bioelectrical impedance analysis (BIA) is a widely used technique to assess body composition and nutritional status. While bioelectrical values are affected by diverse variables, there has been little research on validation of BIA in acute illness, especially to understand prognostic significance. Here we report the use of BIA in acute febrile states induced by influenza. METHODS: Bioimpedance studies were conducted during an H1N1 influenza A outbreak in Venezuelan Amerindian villages from the Amazonas. Measurements were performed on 52 subjects between 1 and 40 years of age, and 7 children were re-examined after starting Oseltamivir treatment. Bioelectrical Impedance Vector Analysis (BIVA) and permutation tests were applied. RESULTS: For the entire sample, febrile individuals showed a tendency toward greater reactance (p=0.058) and phase angle (p=0.037) than afebrile individuals, while resistance and impedance were similar in the two groups. Individuals with repeated measurements showed significant differences in bioimpedance values associated with fever, including increased reactance (p<0.001) and phase angle (p=0.007), and decreased resistance (p=0.007) and impedance (p<0.001). CONCLUSIONS: There are bioelectrical variations induced by influenza that can be related to dehydration, with lower extracellular to intracellular water ratio in febrile individuals, or a direct thermal effect. Caution is recommended when interpreting bioimpedance results in febrile states

    Immediate implant placement in fresh alveolar sockets with a minimal split-thickness envelope flap: A randomised controlled clinical trial

    Get PDF
    OBJECTIVES: Comparing PES/WES scores, modified success rate, survival, success, buccal bone thickness and patient-reported outcomes of immediate dental implants placed in fresh alveolar sockets using a flap or a minimal split-thickness envelope flap (MSTEF). MATERIALS AND METHODS: Implants following random assignment into a flap or MSTEF group were placed immediately in anterior and premolar areas. Guided bone regeneration and autogenous connective tissue graft were used in all cases. A temporary prosthesis was provided followed by the final prosthesis at 16-18 weeks. Success and survival rates together with radiographic buccal bone thickness and patient satisfaction were evaluated at 12 months post-loading. The aesthetic outcome was evaluated through the Pink (PES) and White (WES) Aesthetic Score by 8 blind clinicians of different training background and incorporated in modified success criteria. RESULTS: 28 implants were placed on 28 patients. No statistically significant differences were noted in PES (10.54 control vs. 10.80 test), WES scores (6.97 control vs. 6.95 test) or success criteria including aesthetic parameters (modified success criteria) for the different specialty groups (Range 69%-92%). In addition, no statistically significant differences were noted in survival (100%), success (100%), buccal wall thickness between control (0.72 +/-0.22) and test group (0.92+/-0.31) and patients' reported outcomes. CONCLUSIONS: Immediate dental implant treatment with flap/ MSTEF provided similar mean PES/WES scores, modified success rate, survival, mean buccal bone levels and patients' satisfaction. However, aesthetic failures were common in both groups

    Immediate implant placement in fresh alveolar sockets with a minimal split-thickness envelope flap. A randomised controlled clinical trial.

    Get PDF
    OBJECTIVES: Comparing PES/WES scores, modified success rate, survival, success, buccal bone thickness and patient-reported outcomes of immediate dental implants placed in fresh alveolar sockets using a flap or a minimal split-thickness envelope flap (MSTEF). MATERIALS AND METHODS: Implants following random assignment into a flap or MSTEF group were placed immediately in anterior and premolar areas. Guided bone regeneration and autogenous connective tissue graft were used in all cases. A temporary prosthesis was provided followed by the final prosthesis at 16-18 weeks. Success and survival rates together with radiographic buccal bone thickness and patient satisfaction were evaluated at 12 months post-loading. The aesthetic outcome was evaluated through the Pink (PES) and White (WES) Aesthetic Score by 8 blind clinicians of different training background and incorporated in modified success criteria. RESULTS: 28 implants were placed on 28 patients. No statistically significant differences were noted in PES (10.54 control vs. 10.80 test), WES scores (6.97 control vs. 6.95 test) or success criteria including aesthetic parameters (modified success criteria) for the different specialty groups (Range 69%-92%). In addition, no statistically significant differences were noted in survival (100%), success (100%), buccal wall thickness between control (0.72 +/-0.22) and test group (0.92+/-0.31) and patients' reported outcomes. CONCLUSIONS: Immediate dental implant treatment with flap/ MSTEF provided similar mean PES/WES scores, modified success rate, survival, mean buccal bone levels and patients' satisfaction. However, aesthetic failures were common in both groups

    Spectral distortions from promising single and multifield inflationary models

    Full text link
    Forthcoming missions probing the absolute intensity of the CMB are expected to be able to measure spectral distortions, which are deviations from its blackbody distribution. As cosmic inflation can induce spectral distortions, these experiments offer a possibility to further test the various promising inflationary proposals, whose predictions need to be carefully determined. After numerically fitting all inflationary observables to match current observations, we compute the predicted spectral distortions of various promising single and multifield inflationary models. The predictions of single-field inflationary models display deviations between 1% and 20% with respect to the standard cosmological model in the observable window, where multi-natural and axion-monodromy inflation stand out in this respect. In the case of multifield inflation, we observe a richer structure of the power spectrum, which, in the case of so-called hybrid attractors, yields spectral distortions about 100 times more intense than the standard signal. These observations open up questions about the relation among our results and other cosmological observables that are also to be probed soon.Comment: 30 pages + references, 17 figures, 6 table

    Selective Interactions of Valeriana officinalis Extracts and Valerenic Acid with [3H]Glutamate Binding to Rat Synaptic Membranes

    Get PDF
    Although GABA neurotransmission has been suggested as a mechanism for Valeriana officinalis effects, CNS depression can also be evoked by inhibition of ionotropic (iGluR) and metabotropic glutamate receptors (mGluR). In this study, we examined if aqueous valerian extract interacted with glutamatergic receptors. Freshly prepared aqueous valerian extract was incubated with rat cortical synaptic membranes in presence of 20 nM [3H]Glutamate. Aqueous valerian extract increased [3H]Glutamate binding from 1 × 10−7 to 1 × 10−3 mg/mL. In the presence of (2S,1′S,2′S)-2-(Carboxycyclopropyl)glycine (LCCG-I) and (2S,2′R,3′R)-2-(2′,3′-Dicarboxycyclopropyl)glycine (DCG-IV), Group II mGluR agents, valerian extract markedly decreased [3H]Glutamate binding, while (2S)-2-amino-3-(3,5-dioxo-1,2,4-oxadiazolidin-2-yl) propanoic acid) (quisqualic acid, QA), Group I mGluR agonist, increased [3H]Glutamate binding. At 0.05 mg/mL aqueous valerian extract specifically interacted with kainic acid NMDA and AMPA receptors. Valerenic acid, a marker compound for Valeriana officinalis, increased the [3H]Glutamate binding after 1.6 × 10−2 mg/mL, and at 0.008 mg/mL it interacted only with QA (Group I mGluR). The selective interactions of valerian extract and valerenic acid with Group I and Group II mGluR may represent an alternative explanation for the anxiolytic properties of this plant

    INDOOR MOBILE MAPPING SYSTEMS AND (BIM) DIGITAL MODELS FOR CONSTRUCTION PROGRESS MONITORING

    Get PDF
    Technological developments of the last decades are making possible to speed up different processes involved in construction projects. It is noticeable what building information modeling (BIM) can offer during the entire lifecycle of a project by integrating graphical and non graphical data, in addition to this, mapping the site with a 3D laser scan has been proved to provide a feasible workflow to compare as built models with as designed BIM, in this way, an automatic construction progress monitoring can also be performed. Terrestrial laser scanners (TLS) are commonly used to map a construction site due the level of accuracy provided, but indoor mobile mapping systems (iMMS) could offer a more efficient approach by speeding up the acquisition time and capturing all the details of the site just by walking through it, provided that the point cloud is accurate enough for the purpose of interest. In this paper, an iMMS is used to track the progress of a construction site, the point clouds were uploaded onto a platform of autonomous construction progress monitoring to verify if the system can meet the requirements of available applications. The results showed that the iMMS used is capable to produce point clouds with a quality such that the construction progress monitoring can be performed

    Effect of peri-implant mucosal thickness on esthetic outcomes and the efficacy of soft tissue augmentation procedures: Consensus report of group 2 of the SEPA/DGI/OF workshop

    Get PDF
    OBJECTIVES: The aim of this study was to comprehensively assess the literature in terms of the effect of peri‐implant mucosal thickness on esthetic outcomes and the efficacy of soft tissue augmentation procedures to increase the mucosal thickness with autogenous grafts or soft tissue substitutes. MATERIAL AND METHODS: Two systematic reviews (SR) were performed prior to the consensus meeting to assess the following questions. Review 1, focused question: In systemically healthy patients with an implant‐supported fixed prosthesis, what is the influence of thin as compared to thick peri‐implant mucosa on esthetic outcomes? Review 2, focused question 1: In systemically healthy humans with at least one dental implant (immediate or staged implant), what is the efficacy of connective tissue graft (CTG), as compared to absence of a soft tissue grafting procedure, in terms of gain in peri‐implant soft tissue thickness (STT) reported by randomized controlled clinical trials (RCTs) or controlled clinical trials (CCTs)? Review 2, focused question 2: In systemically healthy humans with at least one dental implant (immediate or staged implant), what is the efficacy of CTG, as compared to soft tissue substitutes, in terms of gain in peri‐implant STT reported by RCTs or CCTs? The outcomes of the two SRs, the consensus statements, the clinical implications, and the research recommendations were discussed and subsequently approved at the consensus meeting during the group and plenary sessions. CONCLUSIONS: There was a tendency of superior esthetic outcomes in the presence of a thick mucosa. The connective tissue graft remains the standard of care in terms of increasing mucosa thickness

    Mechanical performance of AlCrSiN and AlTiSiN coatings on inconel and steel substrates after thermal treatments

    Get PDF
    The objective of this study was to explore the mechanical properties of AlCrSiN and AlTiSiN coatings deposited on Inconel and steel substrates after thermal treatments of 500 °C and 800 °C. Nanoindentation was used to measure the hardness and elastic modulus of the coatings, and microindentation was used for observing the contact damage with Hertzian contact loadings. Microscratch and Mercedes tests were used to evaluate the adhesive strength between coating and substrate with both progressive and static loads, respectively. The surface damage was inspected by optical microscopy and scanning electron microscopy (SEM). Focus ion beams (FIB) were used to mill the cross-sections in order to detect the extent and mode of failure. The results show that AlCrSiN coatings and Inconel substrates exhibit better mechanical performance, even after thermal treatments.Peer ReviewedPostprint (published version