303 research outputs found

    Giant magnetothermal conductivity and magnetostriction effect in charge ordered Nd0.8_{0.8}Na0.2_{0.2}MnO3_{3} compound

    Full text link
    We present results on resistivity (ρ\rho), magnetization (MM), thermal conductivity (κ\kappa), magnetostriction (ΔLL(0)\frac{\Delta L}{L(0)}) and specific heat (CpC_{p}) of charge-orbital ordered antiferromagnetic Nd0.8_{0.8}Na0.2_{0.2}MnO3_{3} compound. Magnetic field-induced antiferromagnetic/charge-orbital ordered insulating to ferromagnetic metallic transition leads to giant magnetothermal conductivity and magnetostriction effect. The low-temperature irreversibility behavior in ρ\rho, MM, κ\kappa and ΔLL(0)\frac{\Delta L}{L(0)} due to field cycling together with striking similarity among the field and temperature dependence of these parameters manifest the presence of strong and complex spin-charge-lattice coupling in this compound. The giant magnetothermal conductivity is attributed mainly to the suppression of phonon scattering due to the destabilization of spin fluctuations and static/dynamic Jahn-Teller distortion by the application of magnetic field.Comment: 4 Pages, 4 Figure

    A Study of Wind Energy Potential in India

    Get PDF
    There is huge activity in wind power, pan-India with the installed capacity increasing to 10,000 MW. India today has the fifth largest installed capacity of wind power in the world with 11087MW installed capacity and potential for on-shore capabilities of 65000MW. However the plant load factor (PLF) in wind power generation is very low, often in the single digits. The increase in interest in wind energy is due to investment subsidies, tax holidays, and government action towards renewable energy playing a big part in nation’s energy system. There is a need to generate environment friendly power that not only raises energy efficiency and is sustainable too. The time has come for moving to generation based subsidies and understanding the drawbacks associated with wind power in India. The capital cost of wind power is third higher than conventional thermal power; further electrical problems like voltage flicker and variable frequency affect the implementation of wind farm. However advances in technologies such as offshore construction of wind turbines, advanced control methodologies, and simulation of wind energy affecting overall grid performance are making a case for wind energy

    Spin dynamics and frequency dependence of magnetic damping study in soft ferromagnetic FeTaC film with a stripe domain structure

    Full text link
    Perpendicular magnetic anisotropy (PMA) and low magnetic damping are the key factors for the free layer magnetization switching by spin transfer torque technique in magnetic tunnel junction devices. The magnetization precessional dynamics in soft ferromagnetic FeTaC thin film with a stripe domain structure was explored in broad band frequency range by employing micro-strip ferromagnetic resonance technique. The polar angular variation of resonance field and linewidth at different frequencies have been analyzed numerically using Landau-Lifshitz-Gilbert equation by taking into account the total free energy density of the film. The numerically estimated parameters Land\'{e} gg-factor, PMA constant, and effective magnetization are found to be 2.1, 2×105\times10^{5} erg/cm3^{3} and 7145 Oe, respectively. The frequency dependence of Gilbert damping parameter (α\alpha) is evaluated by considering both intrinsic and extrinsic effects into the total linewidth analysis. The value of α\alpha is found to be 0.006 at 10 GHz and it increases with decreasing precessional frequency.Comment: 5 Pages, 6 Figures, Regular Submissio

    Laser Optical Simulation of Diffraction from Distorted Lattices

    Get PDF

    Bond Graph model of a vertical U-tube steam condenser coupled with a heat exchanger.

    No full text
    International audienceA simulation model for a vertical U-tube steam condenser in which the condensate is stored at the bottom well is developed in this paper. The U-tubes carrying the coolant are partially submerged in the stored condensate and thus the bottom well acts as a heat exchanger. The storage of hydraulic and thermal energies is represented using a coupled pseudo-bond graph model. Advection effects are modelled by considering reticulated segments of the tubes carrying coolant, over which condensation takes place. The developed model is of intermediate complexity and it is intended for use in observer based real time process supervision, which works by comparing the process behaviour to the reference model outputs. The simulation results obtained from the bond graph model are validated with experimental data from a laboratory set-up

    Variance-Range Function Analysis of X-Ray Line Profile Broadening in Ramie Cellulose

    Get PDF

    Antagonistic activity of cellular components of Pseudomonas species against Aeromonas hydrophila

    Get PDF
    Antagonistic effects of Pseudomonas fluorescens, P. aeruginosa and P. putida were studied against 12 strains of Aeromonas hydrophila (Ah1–Ah12). Four different fractions of cellular component (i.e. whole cell product, heat killed whole cell product, intra cellular product and extra cellular product) of all Pseudomonas species were equally effective in reducing growth of A. hydrophila strains, as measured by the zone of inhibition in an in vitro sensitivity test and have potential action against A. hydrophila infection in fishes
    corecore