192 research outputs found

    Eccentric Figure-Eight Coils for Transcranial Magnetic Stimulation

    Get PDF
    Previously we proposed an eccentric figure-eight coil that can cause threshold stimulation in the brain at lower driving currents. In this study, we performed numerical simulations and magnetic stimulations to healthy subjects for evaluating the advantages of the eccentric coil. The simulations were performed using a simplified spherical brain model and a realistic human brain model. We found that the eccentric coil required a driving current intensity of approximately 18% less than that required by the concentric coil to cause comparable eddy current densities within the brain. The eddy current localization of the eccentric coil was slightly higher than that of the concentric coil. A prototype eccentric coil was designed and fabricated. Instead of winding a wire around a bobbin, we cut eccentric-spiral slits on the insulator cases, and a wire was woven through the slits. The coils were used to deliver magnetic stimulation to healthy subjects; among our results, we found that the current slew rate corresponding to motor threshold values for the concentric and eccentric coils were 86 and 78 A/µs, respectively. The results indicate that the eccentric coil consistently requires a lower driving current to reach the motor threshold than the concentric coil. Future development of compact magnetic stimulators will enable the treatment of some intractable neurological diseases at home. Bioelectromagnetics. 35:55–65, 2015. © 2014 Wiley Periodicals, Inc.ArticleBIOELECTROMAGNETICS. 36(1):55-65 (2015)journal articl

    X-ray magnetic circular dichroism and photoemission study of the diluted ferromagnetic semiconductor Zn1−x_{1-x}Crx_xTe

    Full text link
    We have performed x-ray magnetic circular dichroism (XMCD) and valence-band photoemission studies of the diluted ferromagnetic semiconductor Zn1−x_{1-x}Crx_xTe. XMCD signals due to ferromagnetism were observed at the Cr 2p absorption edge. Comparison with atomic multiplet calculations suggests that the magnetically active component of the Cr ion was divalent under the tetrahedral crystal field with tetragonal distortion along the crystalline a-, b-, and c-axes. In the valence-band spectra, spectral weight near the Fermi level was strongly suppressed, suggesting the importance of Jahn-Teller effect and the strong Coulomb interaction between the Cr 3d electrons

    Soft X-ray Absorption and Photoemission Studies of Ferromagnetic Mn-Implanted 3CC-SiC

    Full text link
    We have performed x-ray photoemission spectroscopy (XPS), x-ray absorption spectroscopy (XAS), and resonant photoemission spectroscopy (RPES) measurements of Mn-implanted 3CC-SiC (3CC-SiC:Mn) and carbon-incorporated Mn5_{5}Si2_{2} (Mn5_{5}Si2_{2}:C). The Mn 2pp core-level XPS and XAS spectra of 3CC-SiC:Mn and Mn5_{5}Si2_{2}:C were similar to each other and showed "intermediate" behaviors between the localized and itinerant Mn 3dd states. The intensity at the Fermi level was found to be suppressed in 3CC-SiC:Mn compared with Mn5_{5}Si2_{2}:C. These observations are consistent with the formation of Mn5_{5}Si2_{2}:C clusters in the 3CC-SiC host, as observed in a recent transmission electron microscopy study.Comment: 4 pages, 3 figure

    Improved beta (local beta >1) and density in electron cyclotron resonance heating on the RT-1 magnetosphere plasma

    Get PDF
    This study reports the recent progress in improved plasma parameters of the RT-1 device. Increased input power and the optimized polarization of electron cyclotron resonance heating (ECRH) with an 8.2 GHz klystron produce a significant increase in electron beta, which is evaluated by an equilibrium analysis of the Grad–Shafranov equation. The peak value of the local electron beta βe is found to exceed 1. In the high-beta and high-density regime, the density limit is observed for H, D and He plasmas. The line-averaged density is close to the cutoff density for 8.2 GHz ECRH. When the filling gas pressure is increased, the density limit still exists even in the low-beta region. This result indicates that the density limit is caused by the cutoff density rather than the beta limit. From the analysis of interferometer data, we found that inward diffusion causes a peaked density profile beyond the cutoff density
    • …
    corecore