209 research outputs found

    Determination of the flow resistivity and thickness of porous materials with rigid frames via transmitted waves at Darcy's regime

    No full text
    International audienceAn acoustic method is proposed for measuring the flow resistivity and the thickness of air-saturated porous materials. The conventional methods [14, 16, 17] for the measurement of the flow resistivity (or the viscous permeability) require the prior knowledge of the porosity. The method presented in this work is based on a temporal model of the direct problem in which a simplified expression (independent of frequency and porosity) of the transmission coefficient at the Darcy’s regime (low frequency range) is established, this expression depends only on the viscous permeability (or the flow resistivity) and the thickness of a porous sample. The inverse problem is solved based on the leastsquare numerical method using experimental transmitted wave in time domain. Tests are performed using two samples of different thicknesses to same industrial plastic foam, thereby enabling the determination the thickness and flow resistivity of foam plastic. This method has the advantage of being simple, fast and efficient

    Ultrasonic propagation of reflected waves in cancellous bone: Application of Biot theory.

    No full text
    International audienceAn ultrasonic propagation in cancellous bone is considered using the Biot theory modified by the Johnson et al. Numerical simulations of reflected waves in the time domain are worked out by varying the modified Biot parameters. The sensitivity of different mechanical parameters : Young modulus and the Poisson ratio of the skeletal frame and physical parameters , porosity , tortuosity and viscous characteristic length are studied showing their effect on the reflected ultrasonic waves of the bone sample. The sensitivity of the modified Biot parameters with respect to the reflected wave depends strongly on the coupling between the solid and fluid phases of the cancellous bone. We show from these simulations that some parameters such as porosity and tortuosity play an important role on reflected wave ; the remaining parameters have low sensitivity compared with the porosity and tortuosity. Experimental results for reflected waves by human cancellous bone samples are given and compared with theoretical predictions

    Measuring static viscous permeability of porous absorbing materials

    No full text
    International audienceConventional acoustical methods for measuring the permeability or flow resistivity of a porous material require a priori estimation of the porosity. In this work, an acoustical method is presented in which a simplified expression (independent of both the frequency and porosity) for the transmitted waves at the Darcy’s regime (low frequency range) is derived, and used for the inverse determination of both the viscous static permeability (or flow resistivity) and the thickness of air-saturated porous materials. The inverse problem is solved based on the least-square numerical method using transmitted waves in time domain. Tests are performed using industrial plastic foams. Experimental and numerical validation results of this method are presented, which show theadvantage of measuring the viscous permeability and thickness of a porous slab, without the required prior knowledge of the porosity, but by simply using the transmitted waves

    Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Molecular Typing of Acinetobacter baumannii in Comparison with Orthogonal Methods

    Get PDF
    Colonization and subsequent health care-associated infection (HCAI) with Acinetobacter baumannii are a concern for vulnerable patient groups within the hospital setting. Outbreaks involving multidrug-resistant strains are associated with increased patient morbidity and mortality and poorer overall outcomes. Reliable molecular typing methods can help to trace transmission routes and manage outbreaks. In addition to methods deployed by reference laboratories, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) may assist by making initial in-house judgments on strain relatedness. However, limited studies on method reproducibility exist for this application. We applied MALDI-TOF MS typing to A. baumannii isolates associated with a nosocomial outbreak and evaluated different methods for data analysis. In addition, we compared MALDI-TOF MS with whole-genome sequencing (WGS) and Fourier transform infrared spectroscopy (FTIR) as orthogonal methods to further explore their resolution for bacterial strain typing. A related subgroup of isolates consistently clustered separately from the main outbreak group by all investigated methods. This finding, combined with epidemiological data from the outbreak, indicates that these methods identified a separate transmission event unrelated to the main outbreak. However, the MALDI-TOF MS upstream approach introduced measurement variability impacting method reproducibility and limiting its reliability as a standalone typing method. Availability of in-house typing methods with well-characterized sources of measurement uncertainty could assist with rapid and dependable confirmation (or denial) of suspected transmission events. This work highlights some of the steps to be improved before such tools can be fully integrated into routine diagnostic service workflows for strain typing. IMPORTANCE Managing the transmission of antimicrobial resistance necessitates reliable methods for tracking outbreaks. We compared the performance of MALDI-TOF MS with orthogonal approaches for strain typing, including WGS and FTIR, for Acinetobacter baumannii isolates correlated with a health care-associated infection (HCAI) event. Combined with epidemiological data, all methods investigated identified a group of isolates that were temporally and spatially linked to the outbreak, yet potentially attributed to a separate transmission event. This may have implications for guiding infection control strategies during an outbreak. However, the technical reproducibility of MALDI-TOF MS needs to be improved for it to be employed as a standalone typing method, as different stages of the experimental workflow introduced bias influencing interpretation of biomarker peak data. Availability of in-house methods for strain typing of bacteria could improve infection control practices following increased reports of outbreaks of antimicrobial-resistant organisms during the COVID-19 pandemic, related to sessional usage of personal protective equipment (PPE)

    Search for CP Violation in the Decay Z -> b (b bar) g

    Full text link
    About three million hadronic decays of the Z collected by ALEPH in the years 1991-1994 are used to search for anomalous CP violation beyond the Standard Model in the decay Z -> b \bar{b} g. The study is performed by analyzing angular correlations between the two quarks and the gluon in three-jet events and by measuring the differential two-jet rate. No signal of CP violation is found. For the combinations of anomalous CP violating couplings, h^b=h^AbgVbh^VbgAb{\hat{h}}_b = {\hat{h}}_{Ab}g_{Vb}-{\hat{h}}_{Vb}g_{Ab} and hb=h^Vb2+h^Ab2h^{\ast}_b = \sqrt{\hat{h}_{Vb}^{2}+\hat{h}_{Ab}^{2}}, limits of \hat{h}_b < 0.59and and h^{\ast}_{b} < 3.02$ are given at 95\% CL.Comment: 8 pages, 1 postscript figure, uses here.sty, epsfig.st

    Application of the hollow fibre infection model (HFIM) in antimicrobial development: a systematic review and recommendations of reporting

    Get PDF
    Item does not contain fulltextOBJECTIVES: This systematic review focuses on the use of the in vitro hollow fibre infection model (HFIM) for microbial culture. We summarize the direction of the field to date and propose best-practice principles for reporting of the applications. METHODS: Searches in six databases (MEDLINE®, EMBASE®, PubMed®, BIOSIS®, SCOPUS® and Cochrane®) up to January 2020 identified 129 studies meeting our inclusion criteria. Two reviewers independently assessed and extracted data from each publication. The quality of reporting of microbiological and technical parameters was analysed. RESULTS: Forty-seven out of 129 (36.4%) studies did not report the minimum pharmacokinetic parameters required in order to replicate the pharmacokinetic profile of HFIM experiments. Fifty-three out of 129 (41.1%) publications did not report the medium used in the HFIM. The overwhelming majority of publications did not perform any technical repeats [107/129 (82.9%)] or biological repeats [97/129 (75.2%)]. CONCLUSIONS: This review demonstrates that most publications provide insufficient data to allow for results to be evaluated, thus impairing the reproducibility of HFIM experiments. Therefore, there is a clear need for the development of laboratory standardization and improved reporting of HFIM experiments

    Measurement of the tau lepton lifetime with the three-dimensional impact parameter method.

    No full text
    A new method is presented for the measurement of the mean τ\tau lepton lifetime using events in which τ\tau's are pair-produced and both τ\tau's decay to hadrons and ντ\nu_\tau. Based on the correlation between the two τ\tau's produced at a symmetric e+ee^+ e^- collider, the 3DIP method relies on the three-dimensional information from a double-sided vertex detector and on kinematic constraints for the precise measurement of the τ\tau decay angles. Using the data collected from 1992 to 1994 with the ALEPH detector at LEP, a τ\tau lifetime of 288.0±3.1±1.3288.0 \pm 3.1 \pm 1.3 \fs is obtained from the sample in which both τ\tau's decay to one charged track, and 292.8±5.6±3.0292.8 \pm 5.6 \pm 3.0 \fs from the sample in which one τ\tau decays to one prong and the other to three prongs. The results show small statistical correlations with those derived from other methods. When combined with the previously published ALEPH measurements, the resulting τ\tau lifetime is 291.2±2.0±1.2291.2 \pm 2.0 \pm 1.2 \fs

    Measurement of the tau lepton lifetime with the three-dimensional impact parameter method.

    No full text
    A new method is presented for the measurement of the mean τ\tau lepton lifetime using events in which τ\tau's are pair-produced and both τ\tau's decay to hadrons and ντ\nu_\tau. Based on the correlation between the two τ\tau's produced at a symmetric e+ee^+ e^- collider, the 3DIP method relies on the three-dimensional information from a double-sided vertex detector and on kinematic constraints for the precise measurement of the τ\tau decay angles. Using the data collected from 1992 to 1994 with the ALEPH detector at LEP, a τ\tau lifetime of 288.0±3.1±1.3288.0 \pm 3.1 \pm 1.3 \fs is obtained from the sample in which both τ\tau's decay to one charged track, and 292.8±5.6±3.0292.8 \pm 5.6 \pm 3.0 \fs from the sample in which one τ\tau decays to one prong and the other to three prongs. The results show small statistical correlations with those derived from other methods. When combined with the previously published ALEPH measurements, the resulting τ\tau lifetime is 291.2±2.0±1.2291.2 \pm 2.0 \pm 1.2 \fs

    Measurement of the tau lepton lifetime with the three-dimensional impact parameter method.

    Get PDF
    A new method is presented for the measurement of the mean τ\tau lepton lifetime using events in which τ\tau's are pair-produced and both τ\tau's decay to hadrons and ντ\nu_\tau. Based on the correlation between the two τ\tau's produced at a symmetric e+ee^+ e^- collider, the 3DIP method relies on the three-dimensional information from a double-sided vertex detector and on kinematic constraints for the precise measurement of the τ\tau decay angles. Using the data collected from 1992 to 1994 with the ALEPH detector at LEP, a τ\tau lifetime of 288.0±3.1±1.3288.0 \pm 3.1 \pm 1.3 \fs is obtained from the sample in which both τ\tau's decay to one charged track, and 292.8±5.6±3.0292.8 \pm 5.6 \pm 3.0 \fs from the sample in which one τ\tau decays to one prong and the other to three prongs. The results show small statistical correlations with those derived from other methods. When combined with the previously published ALEPH measurements, the resulting τ\tau lifetime is 291.2±2.0±1.2291.2 \pm 2.0 \pm 1.2 \fs

    Measurement of the tau lepton lifetime with the three-dimensional impact parameter method.

    Get PDF
    A new method is presented for the measurement of the mean τ\tau lepton lifetime using events in which τ\tau's are pair-produced and both τ\tau's decay to hadrons and ντ\nu_\tau. Based on the correlation between the two τ\tau's produced at a symmetric e+ee^+ e^- collider, the 3DIP method relies on the three-dimensional information from a double-sided vertex detector and on kinematic constraints for the precise measurement of the τ\tau decay angles. Using the data collected from 1992 to 1994 with the ALEPH detector at LEP, a τ\tau lifetime of 288.0±3.1±1.3288.0 \pm 3.1 \pm 1.3 \fs is obtained from the sample in which both τ\tau's decay to one charged track, and 292.8±5.6±3.0292.8 \pm 5.6 \pm 3.0 \fs from the sample in which one τ\tau decays to one prong and the other to three prongs. The results show small statistical correlations with those derived from other methods. When combined with the previously published ALEPH measurements, the resulting τ\tau lifetime is 291.2±2.0±1.2291.2 \pm 2.0 \pm 1.2 \fs
    corecore