The James Webb Space Telescope Mission: Optical Telescope Element Design, Development, and Performance
The James Webb Space Telescope (JWST) is a large, infrared space telescope
that has recently started its science program which will enable breakthroughs
in astrophysics and planetary science. Notably, JWST will provide the very
first observations of the earliest luminous objects in the Universe and start a
new era of exoplanet atmospheric characterization. This transformative science
is enabled by a 6.6 m telescope that is passively cooled with a 5-layer
sunshield. The primary mirror is comprised of 18 controllable, low areal
density hexagonal segments, that were aligned and phased relative to each other
in orbit using innovative image-based wavefront sensing and control algorithms.
This revolutionary telescope took more than two decades to develop with a
widely distributed team across engineering disciplines. We present an overview
of the telescope requirements, architecture, development, superb on-orbit
performance, and lessons learned. JWST successfully demonstrates a segmented
aperture space telescope and establishes a path to building even larger space
telescopes.Comment: accepted by PASP for JWST Overview Special Issue; 34 pages, 25
figure
The Science Performance of JWST as Characterized in Commissioning
This paper characterizes the actual science performance of the James Webb Space Telescope (JWST), as determined from the six month commissioning period. We summarize the performance of the spacecraft, telescope, science instruments, and ground system, with an emphasis on differences from pre-launch expectations. Commissioning has made clear that JWST is fully capable of achieving the discoveries for which it was built. Moreover, almost across the board, the science performance of JWST is better than expected; in most cases, JWST will go deeper faster than expected. The telescope and instrument suite have demonstrated the sensitivity, stability, image quality, and spectral range that are necessary to transform our understanding of the cosmos through observations spanning from near-earth asteroids to the most distant galaxies
Fast spectrally encoded Mueller optical scanning microscopy
Mueller microscopes enable imaging of the optical anisotropic properties of biological or non-biological samples, in phase and amplitude, at sub-micrometre scale. However, the development of Mueller microscopes poses an instrumental challenge: the production of polarimetric parameters must be sufficiently quick to ensure fast imaging, so that the evolution of these parameters can be visualised in real-time, allowing the operator to adjust the microscope while constantly monitoring them. In this report, a full Mueller scanning microscope based on spectral encoding of polarization is presented. The spectrum, collected every 10 μs for each position of the optical beam on the specimen, incorporates all the information needed to produce the full Mueller matrix, which allows simultaneous display of all the polarimetric parameters, at the unequalled rate of 1.5 Hz (for an image of 256 × 256 pixels). The design of the optical blocks allows for the real-time display of linear birefringent images which serve as guidance for the operator. In addition, the instrument has the capability to easily switch its functionality from a Mueller to a Second Harmonic Generation (SHG) microscope, providing a pixel-to-pixel matching of the images produced by the two modalities. The device performance is illustrated by imaging various unstained biological specimens
The Science Performance of JWST as Characterized in Commissioning
This paper characterizes the actual science performance of the James Webb
Space Telescope (JWST), as determined from the six month commissioning period.
We summarize the performance of the spacecraft, telescope, science instruments,
and ground system, with an emphasis on differences from pre-launch
expectations. Commissioning has made clear that JWST is fully capable of
achieving the discoveries for which it was built. Moreover, almost across the
board, the science performance of JWST is better than expected; in most cases,
JWST will go deeper faster than expected. The telescope and instrument suite
have demonstrated the sensitivity, stability, image quality, and spectral range
that are necessary to transform our understanding of the cosmos through
observations spanning from near-earth asteroids to the most distant galaxies.Comment: 5th version as accepted to PASP; 31 pages, 18 figures;
https://iopscience.iop.org/article/10.1088/1538-3873/acb29
Snapshot imaging spectropolarimeter
Distribution UnliuLt:ýJ A revolutionary technique for snapshot imaging spectropolarimetry has been developed because of the recent availability of large focal plane arrays and fast computers. The technique involves the combination of spectropolarimetry with computed tomography imaging spectrometry (CTIS). This spectropolarimeter uses a modulation to encode the spectral dependence of all four Stokes parameters in a single spectrum. CTIS is a snapshot imaging spectrometry method in which both spatial and spectral information is reconstructed using the inverse mathematical technique of medical computed tomography. The combination of these techniques provides the basis for a snapshot imaging complete Stokes spectropolarimeter that can be implemented with no moving parts. This technique is being applied to the SWIR wavelength region to find targets that are camouflaged. 1
Recommended from our members
Design and Optimization of a Complete Stokes Polarimeter for the MWIR
A figure of merit for optimization of a complete Stokes polarimeter based on its measurement matrix is described from the standpoint of singular value decomposition and analysis of variance. It is applied to optimize a system featuring a rotatable retarder and fixed polarizer, and to study the effects of non-ideal retarder properties. A retardance of 132{degree} (approximately three-eighths wave) and retarder orientation angles of {+-}51.7{degree} and {+-}15.1{degree} are favorable when four measurements are used. An achromatic, form-birefringent retarder for the 3--5 {micro}m spectral region has been fabricated and characterized. The effects of non-idealities in the form-birefringent retarder are moderate, and performance superior to that of a quarter-wave plate is expected